Identification of Electrical Tree Aging State in Epoxy Resin Using Partial Discharge Waveforms Compared to Traditional Analysis

被引:4
|
作者
Schurch, Roger [1 ]
Munoz, Osvaldo [2 ]
Ardila-Rey, Jorge [1 ]
Donoso, Pablo [3 ]
Peesapati, Vidyadhar [3 ]
机构
[1] Univ Tecn Federico Santa Maria, Dept Elect Engn, Valparaiso 2390123, Chile
[2] Chilean Independent Syst Operator, Dept Engn & Design, Santiago 9020000, Chile
[3] Univ Manchester, Dept Elect & Elect Engn, Manchester M13 9PL, England
关键词
electrical trees; partial discharges; epoxy resin; pulse waveform; XLPE CABLE INSULATION; PULSE SEQUENCE; GROWTH; PD; SEPARATION; APPARATUS; AC;
D O I
10.3390/polym15112461
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Electrical treeing is one of the main degradation mechanisms in high-voltage polymeric insulation. Epoxy resin is used as insulating material in power equipment such as rotating machines, power transformers, gas-insulated switchgears, and insulators, among others. Electrical trees grow under the effect of partial discharges (PDs) that progressively degrade the polymer until the tree crosses the bulk insulation, then causing the failure of power equipment and the outage of the energy supply. This work studies electrical trees in epoxy resin through different PD analysis techniques, evaluating and comparing their ability to identify tree bulk-insulation crossing, the precursor of failure. Two PD measurement systems were used simultaneously-one to capture the sequence of PD pulses and another to acquire PD pulse waveforms-and four PD analysis techniques were deployed. Phase-resolved PD (PRPD) and pulse sequence analysis (PSA) identified tree crossing; however, they were more sensible to the AC excitation voltage amplitude and frequency. Nonlinear time series analysis (NLTSA) characteristics were evaluated through the correlation dimension, showing a reduction from pre- to post-crossing, and thus representing a change to a less complex dynamical system. The PD pulse waveform parameters had the best performance; they could identify tree crossing in epoxy resin material independently of the applied AC voltage amplitude and frequency, making them more robust for a broader range of situations, and thus, they can be exploited as a diagnostic tool for the asset management of high-voltage polymeric insulation.
引用
收藏
页数:17
相关论文
共 46 条
  • [1] Electrical Tree Growth and Partial Discharge in Epoxy Resin Under Combined AC and DC Voltage Waveforms
    Iddrissu, Ibrahim
    Rowland, Simon M.
    Zheng, Hualong
    Lv, Zepeng
    Schurch, Roger
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2183 - 2190
  • [2] Partial discharge energy and electrical tree volume degraded in epoxy resin
    Schurch, Roger
    Rowland, Simon M.
    Bradley, Robert S.
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 820 - 823
  • [3] Measurement and simulation of electrical tree growth and partial discharge activity in epoxy resin
    Noskov, MD
    Sack, M
    Malinovski, AS
    Schwab, AJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (09) : 1389 - 1398
  • [4] An investigation of partial discharge energy dissipation and electrical tree growth in an epoxy resin
    Brown, MA
    Champion, JV
    Dodd, SJ
    Mudge, P
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, : 288 - 291
  • [5] Systematic and reproducible partial discharge patterns during electrical tree growth in an epoxy resin
    Champion, JV
    Dodd, SJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (03) : 862 - 868
  • [6] The Development of Electrical Tree Discharge in Epoxy Resin Impregnated Paper Insulation
    Wang, Yongqiang
    Feng, Changhui
    Luo, Yu
    IEEE ACCESS, 2020, 8 : 69522 - 69531
  • [7] Degradation Analysis of Epoxy Resin Surfaces Exposed to Partial Discharge
    Ehara, Yoshiyasu
    Aono, Kaiho
    Koshio, Satoshi
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 881 - 884
  • [8] TREE GROWTH IN EPOXY RESIN AT THE FINAL STAGE OF INTERNAL PARTIAL DISCHARGE DEGRADATION.
    Kitamura, Yoichi
    Hirabayashi, Shoji
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1985, 105 (03): : 1 - 8
  • [9] Electrochemical Changes in Epoxy Resin Due to Thermal Aging and Their Effect on Electrical Tree Growth
    Bordeori, Moon Moon
    Gupta, Nandini
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (05) : 1940 - 1947
  • [10] Electrical Tree Aging Characteristics of Epoxy Resin under High Frequency at Different Temperatures
    Zhang, Ling
    Xing, Weiwei
    Xu, Yuxuan
    Cheng, Zixia
    Zhou, Yuanxiang
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 531 - 534