Can Single Cell Respiration be Measured by Scanning Electrochemical Microscopy (SECM)?

被引:9
|
作者
Cremin, Kelsey [1 ,2 ]
Meloni, Gabriel N. [3 ,4 ]
Valavanis, Dimitrios [4 ]
Soyer, Orkun S. [2 ,3 ]
Unwin, Patrick R. [3 ,4 ]
机构
[1] Univ Warwick, Mol Analyt Sci Ctr Doctoral Training MAS CDT, Dept Chem, Bioelect Engn Innovat Hub, Coventry CV4 7AL, England
[2] Univ Warwick, Sch Life Sci, Coventry CV4 7AL, England
[3] Univ Warwick, Bioelect Engn Innovat Hub, Coventry CV4 7AL, England
[4] Univ Warwick, Dept Chem, Coventry CV4 7AL, England
来源
ACS MEASUREMENT SCIENCE AU | 2023年 / 3卷 / 05期
基金
英国工程与自然科学研究理事会;
关键词
SECM; Single cell measurement; OCR; FEM simulations; Respiration; ION CONDUCTANCE MICROSCOPY; OXYGEN-CONSUMPTION; LIVING CELLS; QUANTITATIVE VISUALIZATION; MODE; DIFFUSION; REDUCTION; FEEDBACK; PROBE; PERMEABILITY;
D O I
10.1021/acsmeasuresciau.3c00019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultramicroelectrode (UME), or, equivalently, microelectrode,probesare increasingly used for single-cell measurements of cellular propertiesand processes, including physiological activity, such as metabolicfluxes and respiration rates. Major challenges for the sensitivityof such measurements include: (i) the relative magnitude of cellularand UME fluxes (manifested in the current); and (ii) issues aroundthe stability of the UME response over time. To explore the extentto which these factors impact the precision of electrochemical cellularmeasurements, we undertake a systematic analysis of measurement conditionsand experimental parameters for determining single cell respirationrates via the oxygen consumption rate (OCR) in single HeLa cells.Using scanning electrochemical microscopy (SECM), with a platinumUME as the probe, we employ a self-referencing measurement protocol,rarely employed in SECM, whereby the UME is repeatedly approachedfrom bulk solution to a cell, and a short pulse to oxygen reductionreaction (ORR) potential is performed near the cell and in bulk solution.This approach enables the periodic tracking of the bulk UME responseto which the near-cell response is repeatedly compared (referenced)and also ensures that the ORR near the cell is performed only briefly,minimizing the effect of the electrochemical process on the cell.SECM experiments are combined with a finite element method (FEM) modelingframework to simulate oxygen diffusion and the UME response. Takinga realistic range of single cell OCR to be 1 x 10(-18) to 1 x 10(-16) mol s(-1), resultsfrom the combination of FEM simulations and self-referencing SECMmeasurements show that these OCR values are at, or below, the presentdetection sensitivity of the technique. We provide a set of model-basedsuggestions for improving these measurements in the future but highlightthat extraordinary improvements in the stability and precision ofSECM measurements will be required if single cell OCR measurementsare to be realized.
引用
收藏
页码:361 / 370
页数:10
相关论文
共 50 条
  • [1] Scanning electrochemical microscopy: SECM
    Shiku, H
    Ohya, H
    Matsuei, T
    ELECTROCHEMISTRY, 2001, 69 (10) : 806 - 810
  • [2] Nanostructuring and nanoanalysis by scanning electrochemical microscopy (SECM)
    Ufheil, J
    Hess, C
    Borgwarth, K
    Heinze, J
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2005, 7 (17) : 3185 - 3190
  • [3] Advances on scanning electrochemical microscopy (SECM) for energy
    Bertoncello, Paolo
    ENERGY & ENVIRONMENTAL SCIENCE, 2010, 3 (11) : 1620 - 1633
  • [4] Transport of redox probes through single pores measured by scanning electrochemical-scanning ion conductance microscopy (SECM-SICM)
    Morris, Celeste A.
    Chen, Chiao-Chen
    Baker, Lane A.
    ANALYST, 2012, 137 (13) : 2933 - 2938
  • [5] Diffuse Layer Effect on Electron-Transfer Kinetics Measured by Scanning Electrochemical Microscopy (SECM)
    Bae, Je Hyun
    Yu, Yun
    Mirkin, Michael V.
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2017, 8 (07): : 1338 - 1342
  • [6] Study of the EC' Mechanism by Scanning Electrochemical Microscopy (SECM)
    Calhoun, R. L.
    Bard, A. J.
    GRAHAME AWARD SYMPOSIUM AND PHYSICAL AND ANALYTICAL ELECTROCHEMISTRY (GENERAL) - 219TH ECS MEETING, 2011, 35 (29): : 39 - 51
  • [7] Visualization of DNA microarrays by scanning electrochemical microscopy (SECM)
    Yamashita, K
    Takagi, M
    Uchida, K
    Kondo, H
    Takenaka, S
    ANALYST, 2001, 126 (08) : 1210 - 1211
  • [8] Human Fingerprint Imaging by Scanning ElectroChemical Microscopy (SECM)
    Cortes-Salazar, Fernando
    Zhang, Meiqin
    Becue, Andy
    Busnel, Jean-Marc
    Prudent, Michel
    Champod, Christophe
    Girault, Hubert H.
    CHIMIA, 2009, 63 (09) : 580 - 580
  • [9] Scanning electrochemical microscopy (SECM) as a tool in biosensor research
    Stoica, Leonard
    Neugebauer, Sebastian
    Schuhmann, Wolfgang
    BIOSENSING FOR THE 21ST CENTURY, 2008, 109 : 455 - 492
  • [10] Review-Advances in Scanning Electrochemical Microscopy (SECM)
    Zoski, Cynthia G.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (04) : H3088 - H3100