Synchronous identification of nonlinear structural parameters and unknown external excitation based on improved UKF

被引:3
|
作者
Yuan, Zi-Qing [1 ]
Wang, Zuo-Cai [1 ,2 ,3 ,4 ]
Xin, Yu [1 ,2 ]
Kuang, Xing-Chen [1 ]
Wang, Zhen [1 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Engn Lab Infrastructural Safety Inspect & Mo, Hefei 23009, Anhui, Peoples R China
[3] Anhui Engn Technol Res Ctr Civil Engn Disaster Pre, Hefei 230009, Anhui, Peoples R China
[4] 193 Tunxi Rd, Hefei 230009, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Unscented Kalman filter; Nonlinear structure; Unknown excitation identification; Structural parameters identification; UNSCENTED KALMAN FILTER; INPUT-STATE ESTIMATION; SYSTEM-IDENTIFICATION; DAMAGE DETECTION; LIMITED INPUT; MODEL; BUILDINGS; FORCE;
D O I
10.1016/j.engstruct.2023.117094
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The traditional Unscented Kalman Filter (UKF) approach for nonlinear structural identification usually requires knowledge of external excitation. However, in real application, obtaining the input excitation of nonlinear structures can be challenging due to measurement error or difficulty in acquiring the accurate information. Consequently, the real-time application of the UKF method will be constrained. To address this issue, this paper develops an improved UKF-based synchronous identification method of nonlinear structural parameters and unknown external excitation. The proposed method starts with a preliminary estimate of the unknown excitation using the current predicted values of structural dynamic responses and parameters. Subsequently, the external excitation is further identified based on the updated state vector. In addition, to reduce the effect of measurement noise on the nonlinear structural identification and ensure the accuracy of the identified results, a Kalman Filter (KF) process is embedded in the UKF to optimize measurement noise covariance matrix in real time. The practicability and accuracy of the improved UKF method are confirmed by conducting numerical simulations on a single degree-of-freedom (S-DOF) and a six degree-of-freedom (six-DOF) nonlinear structural systems due to unknown seismic excitation. Moreover, a shake table test of a five-storey steel frame subjected to seismic excitation is employed to attest the feasibility of the proposed method. Both numerical and experimental results demonstrate that the improved UKF method can effectively achieve synchronous identification for nonlinear structural parameters and unknown excitation.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Synchronous Identification for Unknown Loads and Parameters of Nonlinear Structures Based on Improved UKF
    Wang Z.
    Xin Y.
    Wang Z.
    Yuan Z.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2023, 43 (05): : 980 - 987
  • [2] An Improved Sensitivity Method for the Simultaneous Identification of Unknown Parameters and External Loads of Nonlinear Structures
    Wang, Chongwen
    Du, Chengbin
    SHOCK AND VIBRATION, 2018, 2018
  • [3] Identification of Nonlinear Structural Parameters under Unmeasured Excitation
    Lei, Ying
    Wu, Yan
    Li, Tao
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 768 - 772
  • [4] Identification of time-varying nonlinear structural physical parameters by integrated WMA and UKF/UKF-UI
    Yang, Ning
    Li, Jun
    Lei, Ying
    Hao, Hong
    NONLINEAR DYNAMICS, 2021, 106 (01) : 681 - 706
  • [5] Identification of time-varying nonlinear structural physical parameters by integrated WMA and UKF/UKF-UI
    Ning Yang
    Jun Li
    Ying Lei
    Hong Hao
    Nonlinear Dynamics, 2021, 106 : 681 - 706
  • [6] Structural identification with unknown input excitation
    Young Min Choi
    Hyo Nam Cho
    Youn Bok Kim
    Yoon Koog Hwang
    KSCE Journal of Civil Engineering, 2001, 5 (3) : 207 - 213
  • [7] TRAJECTORY SENSITIVITY BASED IDENTIFICATION OF SYNCHRONOUS GENERATOR AND EXCITATION SYSTEM PARAMETERS
    SANCHEZGASCA, JJ
    BRIDENBAUGH, CJ
    BOWLER, CEJ
    EDMONDS, JS
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (04) : 1814 - 1822
  • [8] Simultaneous Identification of Structural Parameter and External Excitation with an Improved Unscented Kalman Filter
    Ding, Y.
    Zhao, B. Y.
    Wu, B.
    Zhang, X. C.
    Guo, L. N.
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (11) : 1981 - 1998
  • [9] An improved Kalman filter with dummy measurement for identification of structural load and unknown parameters
    Wang, Chongwen
    Du, Chengbin
    Ghaemian, Mohsen
    Jiang, Shouyan
    JOURNAL OF SOUND AND VIBRATION, 2024, 569
  • [10] Structural damage identification with unknown external inputs based on the sparse constraint
    Wei, Da
    Li, Dongsheng
    Cai, Enjian
    Huang, Jiezhong
    Guo, Xin
    SMART MATERIALS AND STRUCTURES, 2023, 32 (08)