Temporomandibular joint disorders (TMDs) have always been the subject of studies due to the difficult management of symptoms and the complex stabilization of the so-called therapeutic position. In this effort, digital technologies open new opportunities for such planning, allowing the clinician to digitally assess the situation and verify the stability of the new position from a functional point of view. The present case series shows examples of preliminary full-digital planning of treatment in TMDs patients made with the preliminary evaluation of the kinematic activity of the mandible through a digital device (Tech in motion (TM), ModJaw, Villeurbanne, France). Three TMD clinical cases are analyzed with full-digital techniques and workflow. A personalized treatment for each case was digitally planned on the base of proper kinematic tracings recorded for each patient, and intraoral appliances were digitally customized through a full-digital or semi-digital workflow. The digitalization of mandibular kinematic gave us the possibility of making a more "aware" diagnosis, especially in a dynamic key, and then it allowed a faster realization and execution of the intraoral appliance through a digital workflow, memorizing the therapeutic position and early checking the device, before its realization, on the real kinematics of the patient.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] FULL-DIGITAL WORKFLOW TO REHABILITATE A HIGH VALUE AESTHETIC ZONE: A CASE REPORT
    Carosi, P.
    Pinto, A.
    Quinzi, V.
    Mazzetti, V.
    Cardelli, P.
    Laureti, M.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 79 - 87
  • [2] Immediate Implant Therapy with Full-Digital Workflow to Replace a Central Incisor
    Garcia-Torres, Francisco
    Jurado, Carlos A.
    Rojas-Rueda, Silvia
    Conner, Clint
    Mohamed, Ali Abulkasim
    Azpiazu-Flores, Francisco X.
    DENTISTRY JOURNAL, 2025, 13 (02)
  • [3] Full-Digital Workflow for Fabricating a Custom-Made Direct Metal Laser Sintering (DMLS) Mandibular Implant: A Case Report
    Grecchi, Francesco
    Zecca, Piero Antonio
    Macchi, Aldo
    Mangano, Alessandro
    Riva, Federica
    Grecchi, Emma
    Mangano, Carlo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (08)
  • [4] Tumor detection system for full-digital mammography
    Kobatake, H
    Takeo, H
    Nawano, S
    DIGITAL MAMMOGRAPHY, 1998, 13 : 87 - 94
  • [5] Microcalcification detection system for full-digital mammography
    Kobatake, H
    Takeo, H
    Nawano, S
    DIGITAL MAMMOGRAPHY, 1998, 13 : 201 - 204
  • [6] A Reconfigurable Full-Digital Architecture for Angle of Arrival Estimation
    Florio, Antonello
    Avitabile, Gianfranco
    Talarico, Claudio
    Coviello, Giuseppe
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2024, 71 (03) : 1443 - 1455
  • [7] A Design of Full-Digital CNC Interface Based on FPGA
    Li, Fengge
    You, Jiaxin
    Tong, Weiming
    ITCS: 2009 INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND COMPUTER SCIENCE, PROCEEDINGS, VOL 2, PROCEEDINGS, 2009, : 112 - 115
  • [8] CAD system for full-digital mammography and its evaluation
    Kobatake, H
    Okuno, K
    Murakami, M
    Ishida, M
    Takeo, H
    Nawano, S
    IMAGE PROCESSING - MEDICAL IMAGING 1997, PTS 1 AND 2, 1997, 3034 : 745 - 752
  • [9] A novel method of random equivalent sampling with full-digital reconstruction
    Huang Wuhuang
    Du Yu
    Qiu Duyu
    Ye Peng
    Tian Shulin
    Wang Houjun
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 351 - 360
  • [10] Full-digital control boards for IGBT full-bridge switching converters
    Gaio, E
    Caon, F
    Milani, F
    Toigo, V
    Balbo, N
    Bertacche, G
    Zordan, M
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (04) : 76 - 82