Performance Analysis and Optimization of Coupled Cooling System for Auxiliary Ventilation and Partial Thermal Insulation in High Geothermal Tunnels

被引:1
|
作者
Li, Zijun [1 ]
Jia, Qian [1 ]
Li, Gang [1 ,2 ,3 ]
Xu, Yu [1 ,2 ,4 ]
Wang, Junjian [1 ]
Zhai, Xiaowei [5 ]
机构
[1] Cent South Univ, Sch Resources & Safety Engn, Changsha 410083, Peoples R China
[2] State Key Lab Safety & Hlth Met Mines, Maanshan 243000, Peoples R China
[3] NHC Key Lab Engn Control Dust Hazard, Beijing 102308, Peoples R China
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong 999077, Peoples R China
[5] Xian Univ Sci & Technol, Coll Safety Sci & Engn, Xian 710054, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 05期
基金
中国国家自然科学基金;
关键词
heat hazard; partial insulation performance; coupled cooling; thermal environment; orthogonal test; HEAT-TRANSFER;
D O I
10.3390/app14052128
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A high temperature is the key factor limiting the safe development of deep mine tunnels. By confronting the phenomenon of serious heat exchange between airflow and the surrounding rocks in the tunnel excavation area, a conceptual model of coupled cooling of auxiliary ventilation and partial thermal insulation is proposed. The performance of a coupled cooling system was investigated and optimized by using the scale model test with a 1:10 geometric scale and the orthogonal test. The results suggest that the average temperatures of the work zone and its central point decrease by 1.5 degrees C and 3.3 degrees C, respectively, while partial insulation layers are used. According to the sensitivity analysis for a single factor, as the ventilation duct outlet (VDO) moves away from the working face (WF), the temperature gradually increases, leading to a local high temperature area. When the ventilation duct height is arranged in the middle of the insulation layer, the cooling effect is optimal and the highest average temperature difference is 4.4 degrees C. The thermal equilibrium temperature can be further decreased by lengthening and thickening the insulation layer. In addition, the range analysis shows that the ventilation velocity has a greater impact on the thermal environment of the tunnel working area than the ventilation duct location and insulation layer length. The coupled cooling method can save on cooling capacity and effectively alleviate the high-temperature problems of the tunnel excavation area.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Impact of thermal insulation duct on cooling effect of high-ground-temperature tunnels during construction ventilation
    Zeng, Yanhua
    Yang, Guichang
    Tao, Liangliang
    Ye, Xuqian
    Qi, Zhanfeng
    Yuan, Yanping
    Yan, Jian
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (01) : 187 - 201
  • [2] Impact of thermal insulation duct on cooling effect of high-ground-temperature tunnels during construction ventilation
    Yanhua Zeng
    Guichang Yang
    Liangliang Tao
    Xuqian Ye
    Zhanfeng Qi
    Yanping Yuan
    Jian Yan
    Journal of Thermal Analysis and Calorimetry, 2024, 149 : 187 - 201
  • [3] Numerical Analysis on the Thermal Performance in an Excavating Roadway with Auxiliary Ventilation System
    Li, Zijun
    Liu, Huasen
    Xu, Yu
    Li, Rongrong
    Jia, Mintao
    Zhang, Mengsheng
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) : 1 - 17
  • [4] Improving thermal environment and ventilation efficiency in high-temperature excavation tunnels via an innovative heat insulation and cooling baffle
    Xu, Yu
    Li, Zijun
    Wang, Junjian
    Lu, Yibin
    Cheng, Zi
    Wang, Jingkai
    Lin, Zhang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 55
  • [5] Performance analysis of a large geothermal heating and cooling system
    Naicker, Selvaraj S.
    Rees, Simon J.
    RENEWABLE ENERGY, 2018, 122 : 429 - 442
  • [6] Optimization of Combined Cooling, Heating, and Power System Coupled With Solar and Geothermal Energies
    Ren, Fu-Kang
    Chen, Yi
    Wang, Jiang-Jiang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (01): : 16 - 24
  • [7] Analysis of operational performance of a mechanical ventilation cooling system with latent thermal energy storage
    Santos, Thiago
    Wines, Chris
    Hopper, Nick
    Kolokotroni, Maria
    ENERGY AND BUILDINGS, 2018, 159 : 529 - 541
  • [8] Performance Analysis of a Geothermal Radiant Cooling System Supported by Dehumidification
    Pieska, Henrikki
    Ploskic, Adnan
    Holmberg, Sture
    Wang, Qian
    ENERGIES, 2022, 15 (08)
  • [9] Analysis of the thermal insulation performance of cement with waste glass powder in geothermal well
    Ji, Ying
    Song, Li
    Sha, Qianqian
    Zhu, Gang
    Xue, Yuze
    Zhang, Tinghui
    Fan, Shuai
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [10] Numerical Analysis on the Coupled Operation of Ventilation Window System and Central Cooling System
    Park, Dong Yoon
    Chang, Seongju
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2015, 31 (04) : 385 - 395