Feasibility of intraoperative continuous glucose monitoring: An observational study in general surgery patients

被引:10
|
作者
Price, Catherine E. [1 ,4 ,5 ]
Fanelli, Jessica E. [2 ,6 ]
Aloi, Joseph A. [1 ,5 ]
Anzola, Saskia C. [2 ,6 ]
Vishneski, Susan R. [2 ,6 ]
Saha, Amit K. [2 ,6 ]
Woody, Christopher C. [3 ,7 ]
Segal, Scott [2 ,6 ]
机构
[1] Wake Forest Sch Med, Div Endocrinol & Metab, Winston Salem, NC 27101 USA
[2] Wake Forest Sch Med, Dept Anesthesiol, Winston Salem, NC 27101 USA
[3] Wake Forest Sch Med, Dept Internal Med, Winston Salem, NC 27101 USA
[4] Wake Forest Sch Med, Dept Internal Med, Sect Endocrinol, Med Ctr Blvd, Winston Salem, NC 27157 USA
[5] Wake Forest Sch Med, Dept Internal Med, Div Endocrinol, Med Ctr Blvd, Winston Salem, NC 27157 USA
[6] Wake Forest Sch Med, Dept Anesthesiol, Med Ctr Blvd, Winston Salem, NC 27157 USA
[7] Wake Forest Sch Med, Dept Internal Med, Med Ctr Blvd, Winston Salem, NC 27157 USA
关键词
Continuous glucose monitoring; Diabetes mellitus; Glycemic management; Perioperative; INTENSIVE INSULIN THERAPY; GLYCEMIC CONTROL; PERIOPERATIVE HYPERGLYCEMIA; MANAGEMENT; METAANALYSIS; GUIDELINE; MORTALITY; LIFE;
D O I
10.1016/j.jclinane.2023.111090
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Perioperative hyperglycemia is associated with adverse outcomes in surgical patients, and major societies recommend intraoperative monitoring and treatment targeting glucose <180-200 mg/dL. However, compliance with these recommendations is poor, in part due to fear of unrecognized hypoglycemia. Continuous Glucose Monitors (CGMs) measure interstitial glucose with a subcutaneous electrode and can display the results on a receiver or smartphone. Historically CGMs have not been utilized for surgical patients. We investigated the use of CGM in the perioperative setting compared to current standard practices.Method: This study evaluated the use of Abbott Freestyle Libre 2.0 and/or Dexcom G6 CGMs in a prospective cohort of 94 participants with diabetes mellitus undergoing surgery of >= 3 h duration. CGMs were placed pre-operatively and compared to point of care (POC) BG checks obtained by capillary samples analyzed with a NOVA glucometer. Frequency of intraoperative blood glucose measurement was at the discretion of the anesthesia care team, with a recommendation of once per hour targeting BG of 140-180 mg/dL. Of those consented, 18 were excluded due to lost sensor data, surgery cancellation, or rescheduling to a satellite campus resulting in 76 enrolled subjects. There were zero occurrences of failure with sensor application. Paired POC BG and contem-poraneous CGM readings were compared with Pearson product-moment correlation coefficients, and Bland -Altman plots.Results: Data for use of CGM in perioperative period was analyzed for 50 participants with Freestyle Libre 2.0, 20 participants with Dexcom G6, and 6 participants with both devices worn simultaneously. Lost sensor data occurred in 3 participants (15%) wearing Dexcom G6, 10 participants wearing Freestyle Libre 2.0 (20%) and 2 of the participants wearing both devices simultaneously. The overall agreement of the two CGM's utilized had a Pearson correlation coefficient of 0.731 in combined groups with 0.573 in Dexcom arm evaluating 84 matched pairs and 0.771 in Libre arm with 239 matched pairs. Modified Bland-Altman plot of the difference of CGM and POC BG indicated for the overall dataset a bias of-18.27 (SD 32.10).Conclusions: Both Dexcom G6 and Freestyle Libre 2.0 CGMs were able to be utilized and functioned well if no sensor error occurred at time of initial warmup. CGM provided more glycemic data and further characterized glycemic trends more than individual BG readings. Required time of CGM warm up was a barrier for intra-operative use as well as unexplained sensor failure. CGMs had a fixed warm of time, 1 h for Libre 2.0 and 2 h for Dexcom G6 CGM, before glycemic data obtainable. Sensor application issues did not occur. It is anticipated that this technology could be used to improve glycemic control in the perioperative setting. Additional studies are needed to evaluate use intraoperatively and assess further if any interference from electrocautery or grounding devices may contribute to initial sensor failure. It may be beneficial in future studies to place CGM during preoperative clinic evaluation the week prior to surgery. Use of CGMs in these settings is feasible and warrants further evaluation of this technology on perioperative glycemic management.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Feasibility of intraoperative continuous glucose monitoring: Letter to the editor
    Broz, Jan
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 88
  • [2] Performance of Continuous Glucose Monitoring in Patients With Observational Study
    Liu, Yanhua
    Zhang, Jianna
    Chun, Xueli
    Gao, Yongli
    Yao, Rong
    Liang, Yin
    Zhu, Ling
    He, Ying
    Huang, Wenxia
    ENDOCRINE PRACTICE, 2024, 30 (09) : 795 - 801
  • [3] Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
    Leenen, Jobbe P. L.
    Dijkman, Eline M.
    van Dijk, Joris D.
    van Westreenen, Henderik L.
    Kalkman, Cor
    Schoonhoven, Lisette
    Patijn, Gijsbert A.
    BMJ OPEN, 2021, 11 (02):
  • [4] Feasibility and Precision of Subcutaneous Continuous Glucose Monitoring in Patients Undergoing CABG Surgery
    Aust, Hansjoerg
    Dinges, Gerhard
    Nardi-Hiebl, Stefan
    Koch, Thilo
    Lattermann, Ralph
    Schricker, Thomas
    Eberhart, Leopold H. J.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (05) : 1264 - 1272
  • [5] Continuous glucose monitoring in para cyclists: An observational study
    Weijer, Vera
    van der Werf, Rob
    van der Haijden, Myrthe
    Jeukendrup, Asker
    van Loon, Luc J. C.
    van Dijk, Jan-Willem
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2024, 24 (12) : 1809 - 1819
  • [6] Feasibility and Impact of Focused Intraoperative Transthoracic Echocardiography on Management in Thoracic Surgery Patients: An Observational Study
    Kratz, Thomas
    Holz, Sarah
    Steinfeldt, Thorsten
    Exner, Maik
    dell'Orto, Marco Campo
    Kratz, Caroline
    Wulf, Hinnerk
    Zoremba, Martin
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (02) : 848 - 852
  • [7] Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study
    Torre, Tiziano
    Schlotterbeck, Herve
    Ferraro, Francesco
    Klersy, Catherine
    Surace, Giuseppina
    Toto, Francesca
    Pozzoli, Alberto
    Ferrari, Enrico
    Demertzis, Stefanos
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2024, 32 (04): : 179 - 185
  • [8] CONTINUOUS GLUCOSE MONITORING IN HOSPITALISED PATIENTS AT THE GENERAL WARD
    Schaupp, L.
    Neubauer, K. M.
    Mader, J. K.
    Augustin, T.
    Spat, S.
    Hoell, B.
    Beck, P.
    Plank, J.
    Pieber, T. R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A134 - A134
  • [9] Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients
    Choi, Yoo Jin
    Jeon, Su Min
    Yu, Sehyeon
    Jo, Hye-Sung
    Kim, Dong-Sik
    Yu, Young-Dong
    LANGENBECKS ARCHIVES OF SURGERY, 2025, 410 (01)
  • [10] Accuracy of continuous glucose monitoring in the hospital setting: an observational study
    O'Connor, Mollie Y.
    Flint, Kristen L.
    Sabean, Amy
    Ashley, Annabelle
    Zheng, Hui
    Yan, Joyce
    Steiner, Barbara A.
    Anandakugan, Nillani
    Calverley, Melissa
    Bartholomew, Rachel
    Greaux, Evelyn
    Larkin, Mary
    Russell, Steven J.
    Putman, Melissa S.
    DIABETOLOGIA, 2024, 67 (12) : 2650 - 2659