Influence of inflow directions and setting angle of inlet guide vane on hydraulic performance of an axial-flow pump

被引:11
|
作者
Nguyen, Duc-Anh [1 ,2 ]
Ma, Sang-Bum [2 ]
Kim, Sung [2 ]
Kim, Jin-Hyuk [1 ,2 ]
机构
[1] Univ Sci & Technol, Convergence Mfg Syst Engn Green Proc & Energy Syst, Convergence Mfg Syst Engn, Daejeon 34113, South Korea
[2] Korea Inst Ind Technol, Carbon Neutral Technol R&D Dept, Cheonan 31056, South Korea
关键词
LEAKAGE VORTEX CAVITATION; NUMERICAL-ANALYSIS; TIP CLEARANCE; NOISE;
D O I
10.1038/s41598-023-30511-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Inlet flow direction significantly affects the hydraulic performance of an axial-flow pump. Usually, the research papers ignore this phenomenon, resulting in discrepancies between simulation and experimental results. This study examines the influence of inflow direction in five cases (0%, 5%, 10%, 15%, and 30% pre-swirl intensities) to determine the relationship between the pre-swirl intensity and the hydraulic performance of the axial-flow pump. Based on this, changing the setting angle of the inlet guide vane (IGV) is proposed and thoroughly investigated to reduce the effect of inflow direction. In this study, the influence of clearances in IGV blades on hydraulic performance is also investigated in detail. Numerical simulations are performed using ANSYS-CFX and a shear stress transport reattachment modification (SST k-?) turbulence model with small y+ values at all walls. Specifically, the hydraulic performance curves and internal flow characteristics, including contours and streamlines, are assessed and analyzed. The inflow direction significantly impacts the hydraulic efficiency of the axial-flow pump. Increased pre-swirl intensity causes more loss in the IGV passage. The internal flow field and performance are not affected by the clearance at the hub and shroud of the IGV. However, the tip clearance of the impeller causes a decrease in hydraulic efficiency due to the tip leakage vortex. By adjusting the setting angle of the IGV, the efficiency and head gradually increase from a negative to a positive setting angle. Additionally, 30 degrees is considered the critical setting angle for IGV.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Influence of inflow directions and setting angle of inlet guide vane on hydraulic performance of an axial-flow pump
    Duc-Anh Nguyen
    Sang-Bum Ma
    Sung Kim
    Jin-Hyuk Kim
    Scientific Reports, 13
  • [2] Influence of Inlet Angle of Guide Vane on Hydraulic Performance of an Axial Flow Pump Based on CFD
    Xu, Lei
    Ji, Dongtao
    Shi, Wei
    Xu, Bo
    Lu, Weigang
    Lu, Linguang
    SHOCK AND VIBRATION, 2020, 2020
  • [3] INTERACTIONAL EFFECTS OF INLET GUIDE VANE AND BLADE ANGLE ON HYDRAULIC PERFORMANCE CHARACTERISTICS OF A SUBMERSIBLE AXIAL-FLOW PUMP
    Kim, Youn-Sung
    Shim, Hyeon-Seok
    Kim, Kwang-Yong
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 3, 2018,
  • [4] THE EFFECT OF THE THICKNESS AND ANGLE OF THE INLET AND OUTLET GUIDE VANE ON THE PERFORMANCE OF AXIAL-FLOW PUMP
    Kim, Sang -Won
    Kim, Youn-Jea
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2016, VOL 1A, 2016,
  • [5] Investigation of hydraulic performance in an axial-flow blood pump with different guide vane outlet angle
    Sang, Xiaohu
    Zhou, Xiaojun
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (08): : 1 - 11
  • [6] Influence of Guide Vane Slope on Axial-Flow Hydraulic Performance and Internal Flow Characteristics
    Li, Yue
    Song, Yiwei
    Xia, Shengsheng
    Li, Qiang
    ENERGIES, 2022, 15 (17)
  • [7] Improvement in energy performance from the construction of inlet guide vane and diffuser vane geometries in an axial-flow pump
    Nguyen, Duc-Anh
    Dinh, Cong-Truong
    Kim, Jin-Hyuk
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [8] Improvement in energy performance from the construction of inlet guide vane and diffuser vane geometries in an axial-flow pump
    Duc-Anh Nguyen
    Cong-Truong Dinh
    Jin-Hyuk Kim
    Scientific Reports, 14
  • [9] Effects of inlet guide vane and blade pitch angles on the performance of a submersible axial-flow pump
    Kim, Youn-Sung
    Shim, Hyeon-Seok
    Kim, Kwang-Yong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (04) : 718 - 732
  • [10] Influence of stator vane number on performance of the axial-flow pump
    Kang, Can
    Yu, Xiaojie
    Gong, Weifeng
    Li, Changjiang
    Huang, Qifeng
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (05) : 2025 - 2034