Effects of replacement partial sodium chloride on characteristic flavor substances of bacon during storage based on GCxGC-MS and non-targeted metabolomics analyses

被引:24
|
作者
Ruan, Jinggang [1 ]
Wu, Zhicheng [1 ]
Xu, Jingbing [4 ]
Yu, Yiru [1 ]
Tang, Yong [1 ,2 ]
Xie, Xinrui [1 ]
Chen, Jiaxin [1 ,2 ]
Wang, Zhaoming [1 ,3 ]
Zhang, Dong [1 ,2 ]
Tang, Jie [1 ,2 ]
Li, Hongjun [5 ]
机构
[1] Xihua Univ, Coll Food & Bioengn, Chengdu 610039, Peoples R China
[2] Chongqing Key Lab Special Food Cobuilt Sichuan & C, Chengdu 610039, Peoples R China
[3] Hefei Univ Technol, Coll Food & Bioengn, Hefei 230009, Peoples R China
[4] Chongqing Inst Food & Drug Control, Chongqing 401121, Peoples R China
[5] Southwest Univ, Coll Food Sci, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Bacon; Storage; Volatile compounds; Metabolic substances; LIPID OXIDATION; VOLATILE COMPOUNDS; MEAT; NACL; QUALITY; KCL;
D O I
10.1016/j.foodchem.2023.136805
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Comprehensive 2D gas chromatography-mass spectrometry (GC x GC-MS) and non-targeted metabolomics were employed to investigate the differences in key volatile flavor substances between bacon salted with alternative salt and traditional bacon during storage. The GC x GC-MS analysis revealed that among 146 volatile com-pounds in both types of bacon, alcohol, aldehydes, ketones, phenols, and alkenes were the most abundant. Additionally, non-targeted metabolomics indicated that the changes in amino acids and the oxidation degra-dation of lipids could be the main reasons for the flavor differences among the two kinds of bacon. Furthermore, the acceptability scores of both bacon types showed a general upward trend as the storage time increased, indicating that the metabolic of substances occurring during bacon storage significantly impact its overall quality. By partially substituting sodium chloride with 22% potassium chloride and 11% calcium ascorbate, coupled with appropriate storage conditions, the quality of bacon can be improved.
引用
收藏
页数:10
相关论文
共 2 条
  • [1] A GCxGC-MS method based on solid-state modulator for non-targeted metabolomics: Comparison with traditional GC-MS method
    Zhang, Yueyi
    Ren, Haihui
    Tang, Xiao
    Liu, Qiaorong
    Xiao, Wen
    Zhang, Zunjian
    Tian, Yuan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 243
  • [2] Integrated volatile compounds and non-targeted metabolomics analysis reveal the characteristic flavor formation of proteins in grouper (Epinephelus coioides) during cold storage
    Chu, Yuanming
    Mei, Jun
    Xie, Jing
    FOOD RESEARCH INTERNATIONAL, 2023, 172