Long-term observation of polycaprolactone small-diameter vascular grafts with thickened outer layer and heparinized inner layer in rabbit carotid arteries

被引:3
|
作者
Xiao, Yonghao [1 ]
Jin, Xin [1 ]
Jia, Liujun [2 ]
Li, Jubo [2 ]
Zhang, Baojie [2 ]
Geng, Xue [1 ]
Ye, Lin [1 ]
Zhang, Ai-ying [1 ]
Gu, Yongquan [3 ]
Feng, Zeng-guo [1 ]
机构
[1] Beijing Inst Technol, Sch Mat Sci & Engn, Beijing, Peoples R China
[2] Fuwai Hosp Natl Cardiovasc Ctr, Chinese Acad Med Sci & Peking Union Med Coll, Beijing Key Lab Preclinic Res & Evaluat Cardiovasc, Beijing, Peoples R China
[3] Capital Med Univ, Xuanwu Hosp, Inst Vasc Surg, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
heparinized polycaprolactone; small-diameter vascular grafts; electrospinning; rabbit carotid artery interposition; aneurysm formation; PERFORMANCE;
D O I
10.1088/1748-605X/ad2f6b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In our previous study, the pristine bilayer small-diameter in situ tissue engineered vascular grafts (pTEVGs) were electrospun from a heparinized polycaprolactone (PCL45k) as an inner layer and a non-heparinized PCL80k as an outer layer in the thickness of about 131 mu m and 202 mu m, respectively. However, the hydrophilic enhancement of inner layer stemmed from the heparinization accelerated the degradation of grafts leading to the early formation of arterial aneurysms in a period of 3 months, severely hindering the perennial observation of the neo-tissue regeneration, host cell infiltration and graft remodeling in those implanted pTEVGs. Herein to address this drawback, the thickness of the outer layers was increased with PCL80k to around 268 mu m, while the inner layer remained unchangeable. The thickened TEVGs named as tTEVGs were evaluated in six rabbits via a carotid artery interpositional model for a period of 9 months. All the animals kept alive and the grafts remained patent until explantation except for one whose one side of arterial blood vessels was occluded after an aneurysm occurred at 6 months. Although a significant degradation was observed in the implanted grafts at 9 month, the occurrence of aneurysms was obviously delayed compared to pTEVGs. The tissue stainings indicated that the endothelial cell remodeling was substantially completed by 3 months, while the regeneration of elastin and collagen remained smaller and unevenly distributed in comparison to autologous vessels. Additionally, the proliferation of macrophages and smooth muscle cells reached the maximum by 3 months. These tTEVGs possessing a heparinized inner layer and a thickened outer layer exhibited good patency and significantly delayed onset time of aneurysms.
引用
收藏
页数:13
相关论文
共 26 条
  • [1] Long-term results of triple-layered small diameter vascular grafts in sheep carotid arteries
    Wang, Chengjin
    Li, Zhen
    Zhang, Lei
    Sun, Wei
    Zhou, Jianye
    MEDICAL ENGINEERING & PHYSICS, 2020, 85 : 1 - 6
  • [2] Influence of fiber diameter on the hemocompatibility of small-diameter 3-layer electrospun vascular grafts
    Saidi, M. A.
    Mueller, M.
    Kortlepel, R.
    Glasmacher, B.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S49 - +
  • [3] NONINVASIVE COLOR DOPPLER INSPECTION OF SMALL-DIAMETER VASCULAR GRAFTS IMPLANTED IN CANINE CAROTID AND FEMORAL ARTERIES
    SUNG, HW
    WITZEL, TH
    HATA, C
    TU, R
    QUIJANO, RC
    ARTIFICIAL ORGANS, 1992, 16 (05) : 485 - 489
  • [4] Fabrication Process of Triple-Layer Small-Diameter Vascular Scaffold with Microchannel Structure in the Inner Layer for Accelerated Endothelialization
    Hu, Qingxi
    Wang, Qi
    Liu, Suihong
    Lu, Ye
    Zeng, Zhaoxiang
    Feng, Jiaxuan
    Feng, Rui
    Zhang, Haiguang
    FIBERS AND POLYMERS, 2023, 24 (02) : 469 - 482
  • [5] Fabrication Process of Triple-Layer Small-Diameter Vascular Scaffold with Microchannel Structure in the Inner Layer for Accelerated Endothelialization
    Qingxi Hu
    Qi Wang
    Suihong Liu
    Ye Lu
    Zhaoxiang Zeng
    Jiaxuan Feng
    Rui Feng
    Haiguang Zhang
    Fibers and Polymers, 2023, 24 : 469 - 482
  • [6] Developing small-diameter vascular grafts with human amniotic membrane: long-term evaluation of transplantation outcomes in a small animal model
    Wang, Bo
    Wang, Xiaolong
    Kenneth, Allen
    Drena, Alexander
    Pacheco, Arsenio
    Kalvin, Lindsey
    Ibrahim, EI-Sayed
    Rossi, Peter J.
    Thatcher, Kaitlyn
    Lincoln, Joy
    BIOFABRICATION, 2023, 15 (02)
  • [7] Fabrication of Nanocomposites with High Elasticity and Strength for the Load-Bearing Layer of Small-Diameter Vascular Grafts
    Zizhou, Rumbidzai
    Khoshmanesh, Khashayar
    Wang, Xin
    Houshyar, Shadi
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (29) : 35411 - 35421
  • [8] LONG-TERM RESULTS OF A SMALL-DIAMETER VASCULAR XENOGRAFT (SOLCOGRAFT-P)
    SEEBAUER, L
    HOLZMANN, T
    GEISSDORFER, K
    LICHTI, H
    MAURER, PC
    BLUMEL, G
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1985, 366 : 709 - 709
  • [9] The Potential of a New Natural Vessel Source: Decellularized Intercostal Arteries as Sufficiently Long Small-Diameter Vascular Grafts
    Xia, Yuan
    Zhou, Haiyun
    Ou, Jing-Song
    Liu, Yunqi
    BIOENGINEERING-BASEL, 2024, 11 (07):
  • [10] LONG-TERM RESULTS WITH SMALL-DIAMETER VASCULAR PROSTHESIS SEEDED WITH MICROVASCULAR ENDOTHELIAL-CELLS IN THE CANINE CAROTID-ARTERY
    PASIC, M
    MULLERGLAUSER, W
    LACHAT, M
    BITTMANN, P
    VONSEGESSER, LK
    TURINA, M
    HELVETICA CHIRURGICA ACTA, 1993, 60 (03) : 381 - 385