A Simple and Inexpensive Method to Gain Diatom Absolute Abundances from Permanent Mounts in Hydrobiological and Paleoecological Research

被引:3
|
作者
Cantonati, Marco [1 ,2 ]
Cid-Rodriguez, Maria [2 ,3 ]
Rossi, Floriana [2 ,4 ]
Leira, Manel [5 ,6 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Biol Geol & Environm Sci, BIOME Lab, BiGeA, I-40126 Bologna, Italy
[2] MUSE Museo Sci, Res & Collect Dept Limnol & Phycol, I-38123 Trento, Italy
[3] Univ Vigo, Fac Sci, Dept Ecol & Anim Biol, Vigo 36310, Spain
[4] Univ Aquila, Dept Life Hlth & Environm Sci, I-67100 Laquila, Italy
[5] Univ A Coruna, Fac Sci, BioCost Res Grp, La Coruna 15002, Spain
[6] Univ A Coruna, Ctr Invest Cient Avanzadas CICA, La Coruna 15002, Spain
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 10期
关键词
diatoms; absolute abundances; methodology; mires; microspheres; FOV; SEDIMENTS;
D O I
10.3390/app13106019
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Here, we describe and discuss a method based on microscopical field of view (FOV) area to estimate diatom absolute abundances (densities or concentrations), and we statistically verify its reliability, also comparing it to another commonly used method (microspheres). To test the new method, we purposely performed replicate counts, both with the FOV and with the microsphere method, on both subfossil and recent material (samples) from mires. Intraclass correlation (ICC) revealed a high degree of agreement between the measurements obtained for the replicates with each of the two methods, suggesting that both are reliable for measuring diatom valve concentrations. However, the FOV consistently overestimated diatom absolute abundances, as compared to the microsphere method, and the ICC value used to assess the reliability of the two methods combined suggested that the two methods cannot be used interchangeably. The FOV method is relatively simple, has a lower cost, wider applicability, higher resolution, and warrants compatibility with existing datasets. However, there may also be drawbacks, such as the potential for sample distortion during the concentration process. Therefore, it is important to carefully evaluate the strengths and limitations of the different methods before adopting one for specific research or applied questions.
引用
收藏
页数:9
相关论文
共 1 条
  • [1] Representativity and applicability of small amounts of sediment samples in the determination of absolute diatom abundances (ADA): Evidence from an orbital shaking method
    Huang, Yuanhui
    Ren, Jian
    Deng, Jia
    Shi, Xuefa
    Hu, Limin
    Zou, Jianjun
    Liu, Yanguang
    Ma, Xiaobing
    MARINE MICROPALEONTOLOGY, 2020, 156