Accurate Detection of Doppler Cardiograms With a Parameterized Respiratory Filter Technique Using a K-Band Radar Sensor

被引:32
|
作者
Dong, Shuqin [1 ,2 ]
Li, Yuchen [1 ,2 ]
Lu, Jingyun [1 ,2 ]
Zhang, Zhi [3 ]
Gu, Changzhan [1 ,2 ]
Mao, Junfa [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, MoE Key Lab High Speed Elect Syst, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, MoE Key Lab Artificial Intelligence, Shanghai 200240, Peoples R China
[3] Shanghai Gen Hosp, Shanghai 201613, Peoples R China
基金
美国国家科学基金会;
关键词
Differential Doppler cardiogram (DCG); Doppler cardiogram (DCG); Doppler radar sensor (DRS); heart diseases; parameterized respiratory filter (PRF); MOTION;
D O I
10.1109/TMTT.2022.3184019
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiogram is one of the most important factors for health assessment. As a new expression of cardiograms, the Doppler cardiograms (DCGs) detected remotely via Doppler radar sensor (DRS) provide rich details of the heart motion. However, the existing techniques for measurement of DCG requires that the subject holds his/her breath to avoid the disturbance caused by respiration. To realize the accurate detection of DCGs in the presence of respiration, a high-linearity K-band dc-coupled continuous-wave (CW) DRS with digital dc-tuning function was custom-designed and a novel parameterized respiratory filter (PRF) algorithm was proposed to precisely remove the respiratory signal. Both simulation and experimental results show that the proposed PRF algorithm has better DCG extraction performance than the conventional methods. Furthermore, the experimental results in normal and clinical environments show that the grained differential DCG (D-DCG) has promising potential in professional heart rate variability (HRV) analysis and heart diseases diagnosis, which means the proposed DCGs detection has the potential to be a convenient, comfortable, and reliable way for daily and clinical heart health assessment.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [1] Doppler Cardiogram Detection in the Presence of Respiration with a K-band Radar Sensor
    Dong, Shuqin
    Gu, Changzhan
    Ran, Lixin
    Mao, Jun-Fa
    2022 IEEE RADIO AND WIRELESS SYMPOSIUM (RWS), 2022, : 45 - 48
  • [2] K-Band Doppler Radar is feasible and accurate to record and assess overnight respiratory rate
    Vasireddy, R.
    Roth, C.
    Goette, J.
    Jacomet, M.
    Vogt, A.
    EMBEC & NBC 2017, 2018, 65 : 334 - 337
  • [3] Condition monitoring technique of rotating machinery using K-band Doppler radar
    Im, Yun-Taek
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2018, 60 (03) : 605 - 609
  • [4] Accurate Noncontact Sleep Apnea-hypopnea Detection Using a K-band Biomedical Radar
    Dong, Shuqin
    Wang, Bo
    Gu, Changzhan
    Guo, Yongxin
    2024 15TH GLOBAL SYMPOSIUM ON MILLIMETER-WAVES & TERAHERTZ, GSMM, 2024, : 148 - 150
  • [5] Accurate Noncontact Sleep Apnea-hypopnea Detection Using a K-band Biomedical Radar
    Dong, Shuqin
    Lu, Jingyun
    Li, Yuchen
    Ma, Lina
    Gu, Changzhan
    Mao, Jun-Fa
    2023 ASIA-PACIFIC MICROWAVE CONFERENCE, APMC, 2023, : 432 - 434
  • [6] Detection of Low RCS Unmanned Air Systems Using K-Band Continuous Wave Doppler Radar
    Kyritsis, Alexandros
    Makri, Rodoula
    Uzunoglu, Nikolaos
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2023, 2023
  • [7] Condition monitoring of cooling tower fan using K-band Doppler radar
    Im, Yun-Taek
    Doo, Seung-Gyu
    Hwang, Jeong-Sik
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2019, 61 (01) : 158 - 162
  • [8] Detection of the bright band with a vertically pointing k-band radar
    Pfaff, Thomas
    Engelbrecht, Alexander
    Seidel, Jochen
    METEOROLOGISCHE ZEITSCHRIFT, 2014, 23 (05) : 527 - 534
  • [9] An Improved Performance Radar Sensor for K-Band Automotive Radars
    Abd El-Hameed, Anwer S.
    Ouf, Eman G.
    Elboushi, Ayman
    Seliem, Asmaa G.
    Izumi, Yuta
    SENSORS, 2023, 23 (16)
  • [10] Wearable Indoor Position Tracking using Onboard K-band Doppler Radar and Digital Gyroscope
    Tang, Yao
    Li, Changzhi
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, : 76 - 77