Comparison of Office Blood Pressure, Automated Unattended Office Blood Pressure, Home Blood Pressure, and 24-Hour Ambulatory Blood Pressure Measurements

被引:0
|
作者
Kim, Byung Jin [1 ]
Lee, Sung Ho [1 ]
Lee, Mi Yeon [2 ]
Lee, Seung Jae [1 ]
Choi, Hyo In [1 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Internal Med, Div Cardiol,Sch Med, 29 Saemunan Ro, Seoul 03181, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept R&D Management, Div Biostat,Sch Med, Seoul, South Korea
关键词
Ambulatory Blood Pressure Monitoring; Blood Pressure; Blood Pressure Monitoring; Self; Home Blood Pressure;
D O I
10.3346/jkms.2023.38.e406
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although previous studies have reported differences of blood pressure (BP) according to BP measurement methods, studies in Korean population were scarce. This study aimed to compare BP differences according to different BP measurement methods and assess hypertension phenotype. Methods: This prospective study recruited 183 individuals (mean 55.9 years; 51.4% males). The BP measurements included office BP (auscultatory attended office BP [ausAOBP], automated attended office BP [aAOBP], and automated unattended office BP [aUAOBP]) and out-of-office BP (home BP [HBP] and ambulatory BP [ABP]) measurements taken within one week of each other. Results: The mean systolic/diastolic BP differences between ausAOBP and other BPs according to different BP measurement methods were 3.5/2.3 mmHg for aAOBP; 6.1/2.9 mmHg for aUAOBP; 15.0/7.3 mmHg for daytime ABP; and 10.6/3.4 mmHg for average HBP. The increasing disparity between ausAOBP and other BPs in multivariable regression analysis was significantly associated with increasing BP. The prevalence of white-coat hypertension and masked hypertension in 107 individuals not taking antihypertensive medication was 25.4-26.8% and 30.6-33.3% based on ausAOBP, daytime ABP, and average HBP, respectively. The prevalence of white-coat uncontrolled hypertension and masked uncontrolled hypertension in 76 of those taking antihypertensive medication was 31.7-34.1% and 17.1- 37.1%, respectively. Conclusion: This study showed a large disparity between office BP and out-of-office BP which became more pronounced when office BP by auscultation increased, suggesting that various BP measurement methods should be used to more accurately assess BP status.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [2] Comparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure
    Ringrose, Jennifer S.
    Cena, Jonathan
    Ip, Shannon
    Morales, Fraulein
    Hamilton, Peter
    Padwal, Raj
    CANADIAN JOURNAL OF CARDIOLOGY, 2018, 34 (01) : 61 - 65
  • [3] Blood pressure in office and 24-hour ambulatory blood pressure measurements in patients with treated hypertension
    Stepien-Walek, Alicja
    Kluk, Maciej
    Gorczyca-Michta, Iwona
    Dziubek, Katarzyna
    Salwa, Pawel
    Maroszynska-Dmoch, Ewa
    Wozakowska-Kaplon, Beata
    ARTERIAL HYPERTENSION, 2013, 17 (02): : 184 - 190
  • [4] IN THE AFTERMATH OF SPRINT: FURTHER COMPARISON OF UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT AND 24-HOUR BLOOD PRESSURE MONITORING
    Seidlerova, J. Mlikova
    Gelzinsky, J.
    Materankova, M.
    Ceral, J.
    Filipovsky, J.
    JOURNAL OF HYPERTENSION, 2019, 37 : E193 - E193
  • [5] In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring
    Seidlerova, Jitka
    Gelzinsky, Julius
    Materankova, Marketa
    Ceral, Jiri
    Konig, Petr
    Filipovsky, Jan
    BLOOD PRESSURE, 2018, 27 (05) : 256 - 261
  • [6] THE VALUE OF ATTENDED AND UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE (AOBP) IN CLINICAL PRACTICE: COMPARISON WITH CONVENTIONAL OFFICE BLOOD PRESSURE (OBP) MEASUREMENTS AND 24-HOUR
    Andreadis, E.
    Geladari, C.
    Savva, F.
    Angelopoulos, E.
    Georgantoni, A.
    Apeiranthiti, K.
    Pantikidi, E.
    Papademetriou, V.
    JOURNAL OF HYPERTENSION, 2018, 36 : E218 - E218
  • [7] Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (07): : 1177 - 1183
  • [8] Conventional office blood pressure measurements and unattended automated office blood pressure compared with home self-measurement and 24-h ambulatory blood pressure monitoring
    Fonseca-Reyes, Salvador
    Fonseca-Cortes, Karla
    Coca, Antonio
    Romero-Velarde, Enrique
    Perez-Molina, Jesus
    BLOOD PRESSURE MONITORING, 2023, 28 (01) : 59 - 66
  • [9] Home Blood Pressure Measurements Will or Will Not Replace 24-Hour Ambulatory Blood Pressure Measurement
    O'Brien, Eoin
    HYPERTENSION, 2009, 54 (05) : E128 - E128
  • [10] Home Blood Pressure Measurements Will Not Replace 24-Hour Ambulatory Blood Pressure Monitoring
    Verdecchia, Paolo
    Angeli, Fabio
    Mazzotta, Giovanni
    Gentile, Giorgio
    Reboldi, Gianpaolo
    HYPERTENSION, 2009, 54 (02) : 188 - 194