The influence of prestress level on the behavior of prefabricated precast concrete bridge deck panel systems with different overlay thicknesses

被引:8
|
作者
Al-Rousan, Rajai Z. [1 ]
Alnemrawi, Bara'a R. [1 ]
机构
[1] Jordan Univ Sci & Technol, Dept Civil Engn, Engn, POB 3030, Irbid 22110, Jordan
关键词
Prestress level; Overlays; Bridge deck; NLFEA; Normal bond strength; Shear bond strength; FULL-DEPTH PRECAST; BOND-SLIP BEHAVIOR; REINFORCED-CONCRETE; PERFORMANCE;
D O I
10.1016/j.istruc.2023.105478
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The bond properties and the excellent performance of the applied protecting overlay in segmental bridge deck panels are essential to ensure the overall quality of the bridge system. This research investigates the role of deck panels overlaying in a prefabricated fully-depth precast bridge using the NLFEA simulation approach under various overlaying thicknesses and prestressing levels. Using the NLFEA approach helps reduce the required time, save cost, study the effect of more factors, and demonstrate any behavior at a given load value at a given position in the investigated system. The NLFEA simulation was firstly validated against a published experimental work, and then it was extended into thirty-two prefabricated full-depth bridge systems composed of precast panels under various prestressing levels. The studied prestressing levels were related to the minimum and maximum prestressing levels as follows; (1.38 MPa (aP, Min), 2.76 MPa (2aP, Min), 4.14 MPa (3aP, Min), and 5.52 MPa (aP, max = 4aP, Min)). In addition, the effect of overlaying thickness on the original bridge thickness was also studied (to/ts) of 0.00 (Without), 0.06, 0.12, 0.18, 0.24, 0.30, 0.36, and 0.42). It has been highlighted that concrete overlying has a significant role in improving the system's overall behavior due to its good bonding with the deck panel, including the stiffness, toughness, cracking load, ultimate strength, and ultimate deflection. In addition, the produced stress by the AASHTO HS20 truck is less than the bond strength at the overlying interface. The maximum and minimum practical values for the overlaying thickness were proposed under different pre-stressing levels, aiding in getting the guidance of mitigating the detachment problem under the effect of the AASHTO HS20 truck and impact loading.
引用
收藏
页数:14
相关论文
共 35 条
  • [1] Behavior of Prefabricated Full-Depth Precast Concrete Bridge Deck Panel System: Optimum Prestress Level
    Al-Rousan, Rajai
    1ST INTERNATIONAL CONFERENCE ON OPTIMIZATION-DRIVEN ARCHITECTURAL DESIGN (OPTARCH 2019), 2020, 44 : 607 - 614
  • [2] The impact of overlay's strength and thickness on the behavior of prefabricated precast concrete bridge deck panel system
    Al-Rousan, Rajai Z.
    COMPUTERS AND CONCRETE, 2024, 34 (06): : 723 - 736
  • [3] Composite behavior of precast concrete bridge deck-panel systems
    Sullivan, Sean R.
    Roberts-Wollmann, Carin L.
    Swenty, Matthew K.
    PCI JOURNAL, 2011, : 43 - 59
  • [4] Full-scale testing of prefabricated full-depth precast concrete bridge deck panel system
    Issa, Mohsen A.
    Anderson, Ralph
    Domagalski, Thomas
    Asfour, Shaker
    Islam, M. S.
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 324 - 332
  • [5] Simplified full-depth precast concrete deck panel systems for accelerated bridge construction
    Zhongguo John Ma
    Yulin Zhan
    Lin Xiao
    Lungui Li
    Weiwei Lu
    Journal of Modern Transportation, 2016, 24 (04) : 251 - 260
  • [6] Simplified full-depth precast concrete deck panel systems for accelerated bridge construction
    Ma, Zhongguo John
    Zhan, Yulin
    Xiao, Lin
    Li, Lungui
    Lu, Weiwei
    JOURNAL OF MODERN TRANSPORTATION, 2016, 24 (04): : 251 - 260
  • [7] Adjustable haunch forms for precast concrete bridge deck systems
    Patil, Siddharth
    Ley, Tyler
    Browne, Ralph
    PCI JOURNAL, 2012, : 64 - 77
  • [8] Adjustable haunch forms for precast concrete bridge deck systems
    Patil, S., 1600, Precast/Prestressed Concrete Institute (57):
  • [9] The optimum overlay thickness of prefabricated full-depth precast concrete bridge deck panel system-3D non-linear finite element modeling
    Al-Rousan, Rajai Z.
    Alhassan, Mohammad
    Issa, Mohsen A.
    ENGINEERING STRUCTURES, 2015, 100 : 264 - 275
  • [10] Full scale testing of ultra-high performance concrete closure joint for prefabricated full-depth precast concrete bridge deck panel system
    Stefaniuk, Heather L.
    Semendary, Ali A.
    Svecova, Dagmar