Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage

被引:16
|
作者
Wang, Ji [1 ]
Evans, Michael [2 ]
Belusko, Martin [3 ]
Zhao, Chunrong [4 ]
Liu, Ming [1 ]
Bruno, Frank [1 ]
机构
[1] Univ South Australia, Future Ind Inst, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Univ South Australia, UniSA STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[3] Mondial Advisory, Malvern, SA 5061, Australia
[4] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Darlington, NSW 2006, Australia
关键词
Transcritical CO2 heat pump; Subcooling effect; Simultaneous heating and cooling; Cold thermal energy storage; CARBON-DIOXIDE; REFRIGERATION SYSTEM; TEMPERATURE; CYCLE; OPTIMIZATION; EXCHANGER; PRESSURE; EQUATION; LIQUID; PLANT;
D O I
10.1007/s00231-022-03333-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper studies the combined heating and cooling thermal performance of a CO2 heat pump system considering the sub-cooling effect. For such a system without cold thermal energy storage (CTES), the gas cooler outlet temperature normally needs to be controlled to match the cooling load required. However, the integration of CTES would enable the system to be operated under its optimal conditions depending on the ambient temperatures, i.e. a considerable amount of cooling capac-ity can be generated and stored for later use. A configuration of a CO(2 )heat pump integrated with CTES is described in this paper. A thermodynamic cycle and a simulation model considering the subcooling effect have been developed. The math-ematical model for the pinch point analysis has been newly validated against published experimental data with acceptable agreements. In the case study, the impacts of the subcooling temperature on the optimal combined performance under four ambient temperatures (5 degrees C, 15 degrees C, 25 degrees C, and 32 degrees C) have been studied. The highest optimal combined COP of 5.38 can be achieved when the ambient temperature is 5 degrees C. The detailed profiles of CO2 temperatures, heating and cooling loads, and the COPs when the CTES is in operation have been revealed for the first time. It is found when the ambient temperature is higher than the water inlet temperature (plus the pinch point temperature), the optimal cooling COPs can even have a surge without the subcooling effect, due to a lower sCO(2) temperature leaving the heat exchanger compared to the ambient temperature. Additionally, performance analysis for the CO2 heat pump system with or without CTES is compared, and it is concluded that all optimal heating, cooling, and combined COPs integrated with CTES surpass those without CTES.
引用
收藏
页码:1257 / 1275
页数:19
相关论文
共 50 条
  • [1] Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage
    Ji Wang
    Michael Evans
    Martin Belusko
    Chunrong Zhao
    Ming Liu
    Frank Bruno
    Heat and Mass Transfer, 2023, 59 : 1257 - 1275
  • [2] Numerical performance of a water source transcritical CO2 heat pump with mechanical subcooling
    Illan-Gomez, Fernando
    Garcia-Cascales, Jose R.
    Velasco, F. J. S.
    Oton-Martinez, Ramon A.
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [3] Analysis of performance of CO2 transcritical heat pump system with mechanical subcooling and ejector
    Dong L.
    Li M.
    Yao L.
    Ma Y.
    Zhan H.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (10): : 5431 - 5440
  • [4] A Modified Transcritical CO2 Heat Pump With Mechanical Subcooling for Heating
    He, Yu-Jia
    Cheng, Jia-Hao
    Chang, Meng-Meng
    Shao, Liang-Liang
    Zhang, Chun-Lu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (11): : 2771 - 2774
  • [5] Investigation on the feasibility and performance of transcritical CO2 heat pump integrated with thermal energy storage for space heating
    Wang, Zhihua
    Wang, Fenghao
    Ma, Zhenjun
    Lin, Wenye
    Ren, Haoshan
    RENEWABLE ENERGY, 2019, 134 : 496 - 508
  • [6] Performance study of transcritical CO2 heat pump integrated with ejector and latent thermal energy storage for space heating
    Zhang, Dongwei
    Fang, Chenglei
    Qin, Xiang
    Li, Hang
    Liu, He
    Wu, Xuehong
    ENERGY CONVERSION AND MANAGEMENT, 2022, 268
  • [7] Experimental investigation on thermal characteristics of transcritical CO2 heat pump unit combined with thermal energy storage for residential heating
    Wang, Zhihua
    Wang, Fenghao
    Li, Guichen
    Song, Mengjie
    Ma, Zhenjun
    Ren, Haoshan
    Li, Kehua
    APPLIED THERMAL ENGINEERING, 2020, 165
  • [8] Study on energy-saving performance of a transcritical CO2 heat pump for food thermal process applications
    Liu, Yefeng
    Meng, Deren
    Chen, Shen
    INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [9] Impact of an internal heat exchanger on a transcritical CO2 heat pump under optimal pressure conditions Optimal-pressure performance of CO2 heat pump with IHX
    Oton-Martinez, Ramon A.
    Illan-Gomez, Fernando
    Garcia-Cascales, Jose R.
    Velasco, F. J. S.
    Haddouche, M. Reda
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [10] Performance of a transcritical CO2 heat pump for the food processing industries
    Yarrall, MG
    White, SD
    Cleland, DJ
    Kallu, RDS
    Hedley, RA
    NATURAL WORKING FLUIDS'98: IIR - GUSTAV LORENTZEN CONFERENCE, 1998, 1998 (04): : 203 - 211