Application strategy of finite element analysis in artificial knee arthroplasty

被引:4
|
作者
Zhang, Zi-Heng [1 ,2 ]
Qi, Yan-Song [1 ]
Wei, Bao-Gang [1 ]
Bao, Hu-Ri-Cha [1 ]
Xu, Yong-Sheng [1 ]
机构
[1] Inner Mongolia Peoples Hosp, Orthoped Ctr, Hohhot, Peoples R China
[2] Inner Mongolia Med Univ, Grad Sch, Hohhot, Peoples R China
基金
中国国家自然科学基金;
关键词
artificial knee replacement; artificial joint prosthesis; finite element analysis; bionics; biomechanics; kinematics; prosthesis design; PROXIMAL TIBIAL STRAIN; MOBILE-BEARING; ALL-POLYETHYLENE; COMPONENT ALIGNMENT; CLINICAL-OUTCOMES; CONTACT STRESS; VARUS; WEAR; REPLACEMENT; KINEMATICS;
D O I
10.3389/fbioe.2023.1127289
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Artificial knee arthroplasty, as the most effective method for the treatment of end-stage joint diseases such as knee osteoarthritis and rheumatoid arthritis, is widely used in the field of joint surgery. At present, Finite element analysis (FEA) has been widely used in artificial knee replacement biomechanical research. This review presents the current hotspots for the application of FEA in the field of artificial knee replacement by reviewing the existing research literature and, by comparison, summarizes guidance and recommendations for artificial knee replacement surgery. We believe that lower contact stress can produce less wear and complications when components move against each other, in the process of total knee arthroplasty (TKA), mobile-bearing prostheses reduce the contact surface stress of the tibial-femoral joint compared with fixed-bearing prostheses, thus reducing the wear of the polyethylene insert. Compared with mechanical alignment, kinematic alignment reduces the maximum stress and maximum strain of the femoral component and polyethylene insert in TKA, and the lower stress reduces the wear of the joint contact surface and prolongs the life of the prosthesis. In the unicompartmental knee arthroplasty (UKA), the femoral and tibial components of mobile-bearing prostheses have better conformity, which can reduce the wear of the components, while local stress concentration caused by excessive overconformity of fixed-bearing prostheses should be avoided in UKA to prevent accelerated wear of the components, the mobile-bearing prosthesis maintained in the coronal position from 4 degrees varus to 4 degrees valgus and the fixed-bearing prosthesis implanted in the neutral position (0 degrees) are recommended. In revision total knee arthroplasty (RTKA), the stem implant design should maintain the best balance between preserving bone and reducing stress around the prosthesis after implantation. Compared with cemented stems, cementless press -fit femoral stems show higher fretting, for tibial plateau bone defects, porous metal blocks are more effective in stress dispersion. Finally, compared with traditional mechanical research methods, FEA methods can yield relatively accurate simulations, which could compensate for the deficiencies of traditional mechanics in knee joint research. Thus, FEA has great potential for applications in the field of medicine.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Finite element analysis of unicompartmental knee arthroplasty
    Hopkins, Andrew R.
    New, Andrew M.
    Rodriguez y Baena, Ferdinando
    Taylor, Mark
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (01) : 14 - 21
  • [2] Finite element analysis of sagittal angles of unicompartmental knee arthroplasty
    Yang, Yuzhu
    Guo, Yuan
    Wang, Changjiang
    Zhang, Xushu
    Zhang, Kai
    Ji, Binping
    CLINICAL BIOMECHANICS, 2024, 114
  • [3] Finite element analysis of malposition in bi-unicompartmental knee arthroplasty
    Nicola Armillotta
    Edoardo Bori
    Bernardo Innocenti
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3447 - 3455
  • [4] A finite element analysis for predicting outcomes of cemented total knee arthroplasty
    Gheorghiu, Nicolae
    Socea, Bogdan
    Dimitriu, Mihai C. T.
    Bacalbasa, Nicolae
    Stan, Gabriel
    Orban, Horia
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 21 (03)
  • [5] Coronal malposition effects in total knee arthroplasty: A finite element analysis
    Stan G.
    Orban H.
    Gruionu L.
    Gheorghe P.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (6) : 685 - 690
  • [6] Finite element analysis of malposition in bi-unicompartmental knee arthroplasty
    Armillotta, Nicola
    Bori, Edoardo
    Innocenti, Bernardo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3447 - 3455
  • [7] Finite element analysis of the tibial bone graft in cementless total knee arthroplasty
    Koji Totoribe
    Etsuo Chosa
    Go Yamako
    Hiroaki Hamada
    Koki Ouchi
    Shutaro Yamashita
    Gang Deng
    Journal of Orthopaedic Surgery and Research, 13
  • [8] Finite element analysis in the optimization of posterior-stabilized total knee arthroplasty
    Dagneaux, Louis
    Canovas, Francois
    Jourdan, Franck
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (01)
  • [9] Importance of joint line preservation in unicompartmental knee arthroplasty: Finite element analysis
    Kwon, Oh-Ryong
    Kang, Kyoung-Tak
    Son, Juhyun
    Suh, Dong-Suk
    Baek, Changhyun
    Koh, Yong-Gon
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (02) : 347 - 352
  • [10] Finite element analysis of the tibial bone graft in cementless total knee arthroplasty
    Totoribe, Koji
    Chosa, Etsuo
    Yamako, Go
    Hamada, Hiroaki
    Ouchi, Koki
    Yamashita, Shutaro
    Deng, Gang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13