Study on seismic behavior and collapse risk of super high-rise braced mega frame-core tube structural system

被引:2
|
作者
Shan, Wenchen [1 ]
Zhou, Xuhong [2 ]
Lin, Xuchuan [3 ]
Bao, Lianjin [4 ]
Chen, Y. Frank [5 ]
机构
[1] Southwest Jiaotong Univ, Inst Smart City & Intelligent Transportat, Chengdu 610000, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150080, Peoples R China
[4] East China Architectural Design & Res Inst, Shanghai 200002, Peoples R China
[5] Penn State Univ, Dept Civil Engn, Middletown, PA 17057 USA
基金
中国国家自然科学基金;
关键词
Braced mega frame-core tube (BMFCT); Super high-rise building; mega brace; Fragility analysis; collapse risk; STEEL; SIMULATION; MODEL;
D O I
10.1016/j.soildyn.2023.108409
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The braced mega frame -core tube (BMFCT) structure could provide an efficient lateral -force resisting (LFR) system for high-rise or super high-rise buildings, especially for those higher than 500 m. The BMFCT structure is a dual LFR system, including the outer braced mega frame and the inner core tube. The seismic behavior and design method of this structural system is not clear. In this study, a parametric study based on collapse risktargeted analysis is conducted to clarify seismic mechanism and performance and to make clear means of matching reasonable stiffness and setting energy -dissipation components. Five comparable BMFCT structures with different mega brace stiffness proportions and frame -tube stiffness ratios are designed. An efficient elastoplastic modeling method is introduced to establish the accurate FE models. The corresponding collapse risks are calculated through Incremental Dynamic Analysis and fragility theory. The results show that the structural collapse risk increases with the increased frame -tube stiffness ratio. Therefore,the stiffness and bearing capacity of peripheral frames should be strengthened to ensure the structural collapse margin. On the other hand, the collapse resistance capacity gradually decreases with the increasing of the mega brace stiffness. Thus, the stiffness proportion of mega braces should be recommended to meet the basic lateral stiffness requirements, which shall not exceed 35 % of the overall structural stiffness. Moreover, the distribution feature and ideal arrangement of the energy dissipation components are proposed. The seismic design recommendation based on the uniform collapse risk is also proposed for the BMFCT system, which serves a reference for the structural design of super high-rise buildings.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Influence of outrigger truss system on the seismic fragility of super high-rise braced mega frame-core tube structure
    Shan, Wenchen
    Lin, Xuchuan
    Zhou, Xuhong
    Dong, Biqin
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [2] Seismic analysis of high-rise mega-braced frame-core buildings
    Brunesi, E.
    Nascimbene, R.
    Casagrande, L.
    ENGINEERING STRUCTURES, 2016, 115 : 1 - 17
  • [3] Seismic Behavior of Super High-rise Frame-core Wall Structure
    Yuan Jixing
    Zhang Qing
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 967 - 971
  • [4] Seismic performance of braced mega frame-core tube structure system
    Zhou X.
    Shan W.
    Liu J.
    Lin X.
    Fu X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (01): : 75 - 83
  • [5] Earthquake-induced collapse simulation of a super-tall mega-braced frame-core tube building
    Lu, Xinzheng
    Lu, Xiao
    Guan, Hong
    Zhang, Wankai
    Ye, Lieping
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 82 : 59 - 71
  • [6] Progressive collapse analysis of a typical super high-rise concrete frame-core tube structure exposed to extreme fire
    Ying, Mingjian
    Li, Yi
    Lu, Xinzheng
    Ye, Lieping
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2016, 49 (04): : 48 - 56
  • [7] Structural design and key technology of eccentric high-rise frame-core tube structures
    Wu H.
    Ding J.
    Wang S.
    Yang B.
    Zhang T.
    Geng Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (01): : 154 - 165
  • [8] Experimental investigation on seismic performance of a super high-rise mega frame-double core tube composite structure
    Yi, Jie
    Zhao, Bin
    Yuan, Xuefen
    Lin, Gary
    Lu, Xilin
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [9] Seismic behaviour of high-rise frame-core tube structures considering dynamic soil–structure interaction
    Xiaofeng Zhang
    Harry Far
    Bulletin of Earthquake Engineering, 2022, 20 : 5073 - 5105
  • [10] Study on characteristics of seismic shear distribution in mega frame-core tube structure
    Jiang, Baolong
    Ji, Shuyan
    Li, Yingmin
    Han, Jie
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 39 - 46