AN EXPERIMENTAL INVESTIGATION TO PREDICT OPTIMUM CHARGE OF A HEAT PUMP SYSTEM

被引:0
|
作者
Afshari, Faraz [1 ]
Khanlari, Ataollah [2 ]
Tuncer, Azim Dogus [3 ,4 ]
Soezen, Adnan [5 ]
机构
[1] Erzurum Tech Univ, Fac Engn, Dept Mech Engn, Erzurum, Turkiye
[2] Tarsus Univ, Fac Engn, Dept Mech Engn, Mersin, Turkiye
[3] Burdur Mehmet Akif Ersoy Univ, Fac Engn Architecture, Dept Energy Syst Engn, Burdur, Turkiye
[4] Gazi Univ, Inst Nat & Appl Sci, Ankara, Turkiye
[5] Gazi Univ, Fac Technol, Dept Energy Syst Engn, Ankara, Turkiye
关键词
heat pump; refrigerant; optimization; overcharge; undercharge; REFRIGERANT CHARGE; PERFORMANCE ANALYSIS; AIR-FLOW; WATER;
D O I
10.1615/HeatTransRes.2022044669
中图分类号
O414.1 [热力学];
学科分类号
摘要
Working principles of heat pumps is an important matter from a thermodynamic point of view that has been researched from various aspects. In this study, undercharged, optimum charged, and overcharged conditions of a heat pump were investigated using R134a refrigerant. Variations in temperature, pressure, and the coefficient of performance have been evaluated and it was aimed to find out the optimum charge condition considering different parameters. According to the experimentally obtained findings, the coefficient of performance was increased by more than three times when the refrigerant amount increased from 2000 g to similar to 7300 g. The general outcomes of the present study indicated that optimum refrigerant charge amount can notably affect the performance of heat pump apparatus. It was shown that the P-h diagram of all heat pump systems depends on the working conditions and the refrigerant charge is a very important criterion that can make significant changes in the P-h diagram. It was found that, by increasing refrigerant charge, after the downtrend starts in the compressor inlet temperature, 20% refrigerant can be added to achieve the maximum COP value. Additionally, the critical point in expansion valve outlet temperature was used to find the optimum charge. It was revealed that if 140% refrigerant is added to the given refrigerant at critical point, the optimum COP value can be achieved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Experimental and theoretical investigation of a solar heating system with heat pump
    Kaygusuz, K
    RENEWABLE ENERGY, 2000, 21 (01) : 79 - 102
  • [2] Theoretical and experimental studies on optimum heat rejection pressure for a CO2 heat pump system
    Zhang, X. P.
    Fan, X. W.
    Wang, F. K.
    Shen, H. G.
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2537 - 2544
  • [3] Experimental investigation of exergy, exergoenvironmental and exergoenviroeconomic analysis of the heat pump system
    Yildiz, A.
    Yildirim, R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2022, 19 (11) : 10737 - 10746
  • [4] Experimental investigation of exergy, exergoenvironmental and exergoenviroeconomic analysis of the heat pump system
    A. Yıldız
    R. Yıldırım
    International Journal of Environmental Science and Technology, 2022, 19 : 10737 - 10746
  • [5] Experimental Investigation of Gravity Effect on a Vapor Compression Heat Pump System
    Huang, Zhanfeng
    Li, Tingxun
    ENERGIES, 2023, 16 (11)
  • [6] Experimental Investigation on Transcritical CO2 Heat Pump System
    Liu, Yingfu
    Zhao, Mingxing
    Jin, Guangya
    2016 INTERNATIONAL CONFERENCE ON ARCHITECTURE AND CIVIL ENGINEERING (ICACE 2016), 2016, : 605 - 609
  • [7] Experimental investigation and control optimization of a ground source heat pump system
    Xia, Lei
    Ma, Zhenjun
    McLauchlan, Craig
    Wang, Shugang
    APPLIED THERMAL ENGINEERING, 2017, 127 : 70 - 80
  • [8] EXPERIMENTAL INVESTIGATION ON OPTIMAL TEMPERATURE LIFT OF AN INVERTER HEAT PUMP SYSTEM
    Wang, Fang
    Fan, Xiao-Wei
    Zheng, Hui-Fan
    Xu, Di
    Zhang, Xian-Ping
    THERMAL SCIENCE, 2013, 17 (05): : 1459 - 1465
  • [9] Experimental investigation on a novel heat pump system based on desiccant coated heat exchangers
    Hua, L. J.
    Jiang, Y.
    Ge, T. S.
    Wang, R. Z.
    ENERGY, 2018, 142 : 96 - 107
  • [10] An experimental and theoretical investigation of refrigerant charge on a secondary loop air-conditioning heat pump system in electric vehicles
    Li, Kang
    Xu, Dan
    Lan, Jiao
    Su, Lin
    Fang, Yidong
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (08) : 3381 - 3398