Inter- and Intra-observer Agreement of Visual Estimation, Goniometric and Radiographic Measurement of Passive Thumb Metacarpophalangeal Joint Hyperextension

被引:1
|
作者
Hinckley, Nathaniel B. B. [1 ]
Renfree, Sean [2 ]
Tummala, Sailesh [1 ]
Ivy, Cynthia C. C. [3 ]
Renfree, Kevin J. J. [1 ,4 ]
机构
[1] Mayo Clin, Phoenix, AZ USA
[2] Univ Arizona, Sch Med, Tucson, AZ USA
[3] No Arizona Univ, Dept Occupat Therapy, Phoenix, AZ USA
[4] 5777 E Mayo Blvd, Phoenix, AZ 85054 USA
来源
关键词
Goniometer; Visual estimate; Reliability; MCPJ hyperextension; Thumb arthritis; SURGICAL-TREATMENT; CAPSULODESIS; RELIABILITY; DEFORMITY; ARTHROPLASTY; ARTHRODESIS; ASSOCIATION; MANAGEMENT;
D O I
10.1142/S2424835523500376
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Reliable methods for measuring range of motion is important for hand therapists. Currently, there is no gold standard for the measurement of thumb metacarpophalangeal joint (MCPJ) hyperextension. We hypothesised that visual and goniometric measurements of thumb MCPJ hyperextension vary greater than 10 degrees from radiographic measurements, and between observers.Methods: Twenty-six fresh-frozen hands were measured by a senior orthopaedic resident and fellowship trained hand surgeon. Passive thumb MCPJ hyperextension was measured by visual estimation, goniometry and axis measurement on a lateral thumb radiograph. Raters were blinded to each other's and their own prior measurements. Descriptive statistics were recorded for measurement type and inter-observer agreement using a two-way intra-class correlation coefficient (ICC). Intra-observer agreement was calculated using concordance correlation coefficient (CCC). Bland-Altman plots identified trends, systemic differences or potential outliers.Results: Mean measurements for both raters were similar for visual estimation and radiographic measurements. Mean goniometric measurements were twice as high for Rater B, and closer to radiographic measurements. For both raters, mean radiographic measurements were 10 degrees greater than the other two methods. For inter-rater agreement, measurements were within 10 degrees most frequently with radiographic measurement, then visual estimates, and least by goniometer measurements. Rater B had better agreement comparing visual and goniometric to radiographic measurements.Conclusions: Radiographic measurement has the best inter-observer agreement and precision for evaluating passive thumb MCPJ hyperextension, especially considering adjunct corrective procedures when performing a soft-tissue basal joint arthroplasty. Rater experience improves precision, but there is still poor agreement between visual estimates and goniometer measurements compared to radiographic measurements, as the former two underestimate hyperextension by 10 degrees. Development of a standard method of clinical measurement is needed to improve reliability.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 50 条
  • [1] INTER- AND INTRA-OBSERVER AGREEMENT IN THE MILCH AND WEISS SYSTEMS
    Charles Lozoya, Sergio
    Trevino Baez, Joaquin Dario
    Rangel Flores, Jesus Maria
    Brizuela Ventura, Jesus Miguel
    Araiza Topete, Omar
    Alcazar Juarez, Andrea
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 218 - 221
  • [2] An independent inter- and intra-observer agreement assessment of the Eno classification of sacroiliac joint degeneration
    Urrutia, Julio
    Camino-Willhuber, Gaston
    Astur, Nelson
    Valacco, Marcelo
    Borensztein, Matias
    Velan, Osvaldo
    Cikutovic, Pablo
    ACTA RADIOLOGICA, 2022, 63 (08) : 1071 - 1076
  • [3] Intrapartum ultrasound for cervical dilatation: Inter- and intra-observer agreement
    Hanidu, Arwa
    Kovalenko, Mariya
    Usman, Sana
    Monasta, Lorenzo
    Zamagni, Giulia
    Stampalija, Tamara
    Lees, Christoph
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2024, 103 (12) : 2455 - 2464
  • [4] Intrapartum ultrasound for cervical dilatation: Inter- and intra-observer agreement
    Hanidu, Arwa
    Kovalenko, Mariya
    Usman, Sana
    Monasta, Lorenzo
    Zamagni, Giulia
    Stampalija, Tamara
    Lees, Christoph
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2024, 132 : 39 - 39
  • [5] Inter- and intra-observer agreement and image reconstruction effects on visual and quantitative assessment of DaTSCANs.
    Shabo, G.
    Kettle, A. G.
    O'Doherty, M. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S301 - S301
  • [6] Inter- and intra-observer agreement in arthroscopic assessment of the long head of the biceps
    Saad, Maxime
    Charousset, Christophe
    Berhouet, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (02)
  • [7] Remote Assessment of Wrist Range of Motion: Inter- and Intra-Observer Agreement of Provider Estimation and Direct Measurement With Photographs and Tracings
    Scott, Kelly L.
    Skotak, Cecelia M.
    Renfree, Kevin J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (11): : 954 - 965
  • [8] Inter-observer and intra-observer agreement in the interpretation of visual fields in glaucoma
    King, AJ
    Farnworth, D
    Thompson, JR
    EYE, 1997, 11 (5) : 687 - 691
  • [9] Inter-observer and intra-observer agreement in the interpretation of visual fields in glaucoma
    A J King
    D Farnworth
    J R Thompson
    Eye, 1997, 11 : 687 - 691
  • [10] Inter- and intra-observer agreement on Miller’s classification of gingival tissue recessions
    Kristina Bertl
    Dorothea Ruckenbauer
    Michael Müller-Kern
    Gerlinde Durstberger
    Stefan Lettner
    Corinna Bruckmann
    Christian Ulm
    Odontology, 2015, 103 : 292 - 300