Biomechanical Performance of Transtibial Pull-Out Posterior Horn Medial Meniscus Root Repair Is Improved With Knotless Adjustable Suture Anchor-Based Fixation

被引:3
|
作者
Bachmaier, Samuel [1 ,2 ,8 ]
Krych, Aaron J. [3 ,4 ]
Smith, Patrick A. [5 ]
Feucht, Matthias J. [6 ]
LaPrade, Robert F. [7 ]
Wijdicks, Coen A. [1 ]
机构
[1] Arthrex Dept Orthoped Res, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Musculoskeletal Univ Ctr Munich MUM, Univ Hosp, Dept Orthopaed & Trauma Surg, Munich, Germany
[3] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
[4] Mayo Clin, Sports Med Ctr, Rochester, MN USA
[5] Univ Missouri, Columbia, MO USA
[6] Diakonie Klinikum, Dept Orthopaed Surg Paulinenhilfe, Stuttgart, Germany
[7] Twin Cities Orthoped, Edina, MN USA
[8] Arthrex GmbH, Dept Orthoped Res, Erwin Hielscher St 9, D-81249 Munich, Germany
关键词
knee; meniscus; meniscus root; root tear; adjustable pull-out repair; biomechanics of ligament; ALL-INSIDE; TEAR; CONSEQUENCES; ATTACHMENT; STRENGTH; DEVICES;
D O I
10.1177/23259671241239575
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: While posterior medial meniscus root (PMMR) techniques have evolved, there remains a need to both optimize repair strength and improve resistance to cyclic loading. Hypothesis: Adjustable tensioning would lead to higher initial repair strength and reduce displacement with cyclic loading compared with previously described transtibial pull-out repair (TPOR) fixation techniques. Study Design: Controlled laboratory study. Methods: A total of 56 porcine medial menisci were used. Eight intact specimens served as a control for the native meniscus. For the others, PMMR tears were created and repaired with 6 different TPOR techniques (8 in each group). Fixed PMMR repairs were executed using 4 different suture techniques (two No. 2 cinch sutures, two cinch tapes, two No. 2 simple sutures, and two No. 2 sutures in a Mason-Allen configuration) all tied over a cortical button. Adjustable PMMR repairs using Mason-Allen sutures were fixed with an adjustable soft tissue anchor fixation tensioned at either 80 N or 120 N. The initial force, stiffness, and relief displacement of the repairs were measured after fixation. Repair constructs were then cyclically loaded, with cyclic displacement and stiffness measured after 1000 cycles. Finally, the specimens were pulled to failure. Results: The PMMR repaired with the 2 cinch sutures fixed technique afforded the lowest (P < .001) initial repair load, stiffness, and relief displacement. The adjustable PMMR repairs achieved a higher initial repair load (P < .001) and relief displacement (P < .001) than all fixed repairs. The 2 cinch sutures fixed technique showed an overall higher cyclic displacement (P < .028) and was completely loose compared with the native meniscus functional zone. Repairs with adjustable intratunnel fixation showed displacement with cyclic loading similar to the native meniscus. With cyclic loading, the Mason-Allen adjustable repair with 120 N of tension showed less displacement (P < .016) than all fixed repairs and a stiffness comparable to the fixed Mason-Allen repair. The fixed Mason-Allen technique demonstrated a higher ultimate load (P < .007) than the adjustable Mason-Allen techniques. All repairs were less stiff, with lower ultimate failure loads, than the native meniscus root attachment (P < .0001). Conclusion: Adjustable TPOR led to considerably higher initial repair load and relief displacement than other conventional fixed repairs and restricted cyclic displacement to match the native meniscus function. However, the ultimate failure load of the adjustable devices was lower than that of a Mason-Allen construct tied over a cortical button. All repair techniques had a significantly lower load to failure than the native meniscus root. Clinical Relevance: Knotless adjustable PMMR repair based on soft anchor fixation results in higher tissue compression and less displacement, but the overall clinical significance on healing rates remains unclear.
引用
收藏
页数:10
相关论文
共 37 条
  • [1] Biomechanical Comparison Between Suture Anchor and Transtibial Pull-out Repair for Posterior Medial Meniscus Root Tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (01): : 187 - 193
  • [2] Arthroscopic Medial Meniscus Posterior Horn Direct Anchor Root Repair: Transtibial Approach With Knotless Adjustable Aperture Fixation
    Lee, Dustin R.
    Clark, Sean C.
    Daniel, Adam V.
    Krych, Aaron J.
    Smith, Patrick A.
    ARTHROSCOPY TECHNIQUES, 2024, 13 (05):
  • [3] Primary Fixation and Cyclic Performance of Posterior Horn Medial Meniscus Root Repair With Knotless Adjustable Suture Anchor-Based Fixation: A Human Biomechanical Evaluation Over 100,000 Loading Cycles
    Bachmaier, Samuel
    Krych, Aaron J.
    Smith, Patrick A.
    Nuelle, Clayton W.
    Mueller, Peter E.
    Bedi, Asheesh
    Wijdicks, Coen A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2025,
  • [4] Biomechanical Evaluation of Different Suture Techniques for Arthroscopic Transtibial Pull-out Repair of Posterior Medial Meniscus Root Tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (12): : 2784 - 2790
  • [5] Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears
    Feucht, Matthias J.
    Grande, Eduardo
    Brunhuber, Johannes
    Rosenstiel, Nikolaus
    Burgkart, Rainer
    Imhoff, Andreas B.
    Braun, Sepp
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (01) : 132 - 139
  • [6] Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears
    Matthias J. Feucht
    Eduardo Grande
    Johannes Brunhuber
    Nikolaus Rosenstiel
    Rainer Burgkart
    Andreas B. Imhoff
    Sepp Braun
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 132 - 139
  • [7] Arthroscopic Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tear With a Whip Running Suture Technique
    Kim, Joo-Hwan
    Ryu, Dong-Jin
    Park, Jae Sung
    Shin, Tae Soo
    Wang, Joon Ho
    ARTHROSCOPY TECHNIQUES, 2021, 10 (04): : E1017 - E1024
  • [8] Medial Meniscus Root Repair: A Transtibial Pull-Out Surgical Technique
    Hevesi, Mario
    Stuart, Michael J.
    Krych, Aaron J.
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (03) : 205 - 209
  • [9] Different Suture Materials for Arthroscopic Transtibial Pull-out Repair of Medial Meniscal Posterior Root Tears A Human Biomechanical Study
    Nakama, Gilberto Y.
    Aman, Zachary S.
    Storaci, Hunter W.
    Kuczmarski, Alexander S.
    Krob, Joseph J.
    Strauss, Marc J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (09)
  • [10] Short-term results of tibial interference screw fixation for transtibial medial meniscus posterior root pull-out repair
    Schlumberger, Michael
    Michalski, Stefan
    Beel, Wouter
    Mayer, Philipp
    Schuster, Philipp
    Immendoerfer, Micha
    Mayr, Raul
    Richter, Joerg
    JOURNAL OF ORTHOPAEDICS, 2024, 50 : 155 - 161