Carbon fiber-reinforced PEEK spinal implants for primary and metastatic spine tumors: a systematic review on implant complications and radiotherapy benefits

被引:10
|
作者
Khan, Hammad A. [1 ]
Ber, Roee [1 ]
Neifert, Sean N. [1 ]
Kurland, David B. [1 ]
Laufer, Ilya [1 ]
Kondziolka, Douglas [1 ]
Chhabra, Arpit [2 ]
Frempong-Boadu, Anthony K. [1 ]
Lau, Darryl [1 ,3 ]
机构
[1] NYU Grossman Sch Med, Dept Neurosurg, New York, NY USA
[2] New York Proton Ctr, New York, NY USA
[3] NYU Langone Hlth, New York, NY 10016 USA
关键词
carbon fiber PEEK; implant complications; spine metastases; oncological outcomes; oncology; tumor; SEPARATION SURGERY; SURGICAL RESECTION; RADIATION-THERAPY; HARDWARE FAILURE; CHORDOMAS; MANAGEMENT; OUTCOMES; INSTRUMENTATION; CHONDROSARCOMAS; CANCER;
D O I
10.3171/2023.5.SPINE23106
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE By minimizing imaging artifact and particle scatter, carbon fiber-reinforced polyetheretherketone (CF-PEEK) spinal implants are hypothesized to enhance radiotherapy (RT) planning/dosing and improve oncological outcomes. However, robust clinical studies comparing tumor surgery outcomes between CF-PEEK and traditional metallic implants are lacking. In this paper, the authors performed a systematic review of the literature with the aim to describe clinical outcomes in patients with spine tumors who received CF-PEEK implants, focusing on implant-related complications and oncological outcomes.METHODS A systematic review of the literature published between database inception and May 2022 was performed in accordance with the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The PubMed database was queried using the terms "carbon fiber" and "spine" or "spinal." The inclusion criteria were articles that described patients with CF-PEEK pedicle screw fixation and had a minimum of 5 patients. Case reports and phantom studies were excluded.RESULTS This review included 11 articles with 326 patients (237 with CF-PEEK-based implants and 89 with titaniumbased implants). The mean follow-up period was 13.5 months, and most tumors were metastatic (67.1%). The rates of implant-related complications in the CF-PEEK and titanium groups were 7.8% and 4.7%, respectively. The rate of pedicle screw fracture was 1.7% in the CF-PEEK group and 2.4% in the titanium group. The rates of reoperation were 5.7% (with 60.0% because of implant failure or junctional kyphosis) and 4.8% (all because of implant failure or junctional kyphosis) in the CF-PEEK and titanium groups, respectively. When reported, 72.5% of patients received postoperative RT (41.0% stereotactic body RT, 30.8% fractionated RT, 25.6% proton, 2.6% carbon ion). Four articles suggested that implant artifact was reduced in the CF-PEEK group. Local recurrence occurred in 14.4% of CF-PEEK and 10.7% of titaniumimplanted patients.CONCLUSIONS While CF-PEEK harbors similar implant failure rates to traditional metallic implants with reduced imaging artifact, it remains unclear whether CF-PEEK implants improve oncological outcomes. This study highlights the need for prospective, direct comparative clinical studies.
引用
收藏
页码:534 / 547
页数:14
相关论文
共 32 条
  • [1] Carbon fiber-reinforced PEEK in implant dentistry: A scoping review on the finite element method
    Souza, Julio C. M.
    Pinho, Sofia S.
    Braz, Maria Pranto
    Silva, Filipe S.
    Henriques, Bruno
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (12) : 1355 - 1367
  • [2] Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants for Treatment of Spinal Tumors : Perceived Advantages and Limitations
    Alvarez-Breckenridge, Christopher
    de Almeida, Romulo
    Haider, Ali
    Muir, Matthew
    Bird, Justin
    North, Robert
    Rhines, Laurence
    Tatsui, Claudio
    NEUROSPINE, 2023, 20 (01) : 317 - 326
  • [3] Commentary on "Carbon Fiber-Reinforced Polyetheretherketone Spinal Implants for Treatment of Spinal Tumors: Perceived Advantages and Limitations"
    Chi, John H.
    NEUROSPINE, 2023, 20 (01) : 327 - 328
  • [4] The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review
    Li, Chuan Silvia
    Vannabouathong, Christopher
    Sprague, Sheila
    Bhandari, Mohit
    CLINICAL MEDICINE INSIGHTS-ARTHRITIS AND MUSCULOSKELETAL DISORDERS, 2015, 8 : 33 - 45
  • [5] The Use of Carbon Fiber-Reinforced Instrumentation in Patients with Spinal Oncologic Tumors: A Systematic Review of Literature and Future Directions
    Perez-Roman, Roberto J.
    Boddu, James, V
    Bashti, Malek
    Bryant, Jean-Paul
    Amadasu, Efosa
    Gyedu, Joseph S.
    Wang, Michael Y.
    WORLD NEUROSURGERY, 2023, 173 : 13 - 22
  • [6] In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model
    Nakahara, Ichiro
    Takao, Masaki
    Bandoh, Shunichi
    Bertollo, Nicky
    Walsh, William R.
    Sugano, Nobuhiko
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (03) : 485 - 492
  • [7] Carbon fiber-reinforced PEEK as a framework material for single implant-retained mandibular overdentures
    Borges, Guilherme Almeida
    Mesquita, Marcelo Ferraz
    Matias, Luana Figueiredo da Silva
    Barbin, Thais
    Machado, Leonardo Mendes Ribeiro
    Barao, Valentim Adelino Ricardo
    BRAZILIAN ORAL RESEARCH, 2025, 39
  • [8] Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report
    Stefano Boriani
    Giuseppe Tedesco
    Lu Ming
    Riccardo Ghermandi
    Maurizio Amichetti
    Piero Fossati
    Marco Krengli
    Loredana Mavilla
    Alessandro Gasbarrini
    European Spine Journal, 2018, 27 : 874 - 881
  • [9] Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report
    Boriani, Stefano
    Tedesco, Giuseppe
    Ming, Lu
    Ghermandi, Riccardo
    Amichetti, Maurizio
    Fossati, Piero
    Krengli, Marco
    Mavilla, Loredana
    Gasbarrini, Alessandro
    EUROPEAN SPINE JOURNAL, 2018, 27 (04) : 874 - 881
  • [10] The influence of sterilization processes on the micromechanical properties of carbon fiber-reinforced PEEK composites for bone implant applications
    Godara, A.
    Raabe, D.
    Green, S.
    ACTA BIOMATERIALIA, 2007, 3 (02) : 209 - 220