Characteristics, secondary transformation and odor activity evaluation of VOCs emitted from municipal solid waste incineration power plant

被引:15
|
作者
Sun, Chengyi [1 ]
Wang, Zhiping [1 ]
Yang, Yong [1 ]
Wang, Minyan [1 ]
Jing, Xianglong [1 ]
Li, Guoao [1 ]
Yan, Jing [1 ]
Zhao, Liyun [1 ]
Nie, Lei [1 ]
Wang, Yiqi [2 ]
Zhong, Yuxi [3 ]
Liu, Yang [4 ]
机构
[1] Beijing Municipal Res Inst Eco Environm Protect, Natl Engn Res Ctr Urban Environm Pollut Control, Beijing Key Lab Urban Atmospher Volatile Organ Cp, Beijing 100037, Peoples R China
[2] Univ Tokyo, Grad Sch Frontier Sci, Dept Environm Syst, Kashiwanoha 5-1-5, Kashiwa, Chiba 2778563, Japan
[3] Beijing Inst Technol, Sch Mat Sci&Engn, Beijing 100081, Peoples R China
[4] Univ Calif Davis, Dept Environm Sci & Management, Coll Agr & Environm Sci, 1 Shields Ave, Davis, CA 95616 USA
关键词
Municipal solid waste incineration power plant; VOCs; Ozone formation potential; Secondary organic aerosol formation potential; Odor activity evaluation; VOLATILE ORGANIC-COMPOUNDS; HEALTH-RISK ASSESSMENT; MSWI FLY-ASH; SOURCE APPORTIONMENT; AEROSOL FORMATION; SULFUR-COMPOUNDS; EMISSION CHARACTERISTICS; IMPACT ASSESSMENT; OZONE FORMATION; WORKING FACE;
D O I
10.1016/j.jenvman.2022.116703
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Volatile organic compounds (VOCs) emitted from municipal solid waste incineration power plant (MSWIPP) plays a significant role in the formation of O-3 and PM2.5 and odor pollution. Field test was performed on four MSWIPPs in an area of the North China Plain. Nonmethane hydrocarbons (NMHCs) and 102 VOCs were identified and quantified. Ozone formation potential (OFP), secondary organic aerosol formation potential (SOAFP), and odor activity of the detected VOCs were evaluated. Results showed that the average concentration of NMHCs and VOCs were 1648.6 +/- 1290.4 mu g/m(3) and 635.3 +/- 588.8 mu g/m(3), respectively. Aromatics (62.1%), O-VOCs (16.0%), and halo hydrocarbons (10.0%) were the main VOCs groups in the MSWIPP exhaust gas. VOCs emission factor of MSWIPP was 2.43 x 10(3) +/- 2.27 x 10(3) ng/g-waste. The OFP and SOAFP of MSWIPP were 960.18 +/- 2158.17 mu g/m(3) and 1.57 +/- 3.38 mu g/m(3), respectively. Acrolein as the dominant VOC species was the major odor contributor with a percentage of odor contribution of 65.9%. Benzene and 1,2,4-trimethylbenzene as the dominant VOC species were the main contributors of O-3 formation potentials, in which 1,2,4-trimethylbenzene was also the main contributors of SOA formation potential.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Characteristics of different volatility classes of organic compounds emitted by a municipal solid waste incineration plant
    Fujitani, Yuji
    Sato, Kei
    Tanabe, Kiyoshi
    Morino, Yu
    Takahashi, Katsuyuki
    Hoshi, Junya
    ATMOSPHERIC ENVIRONMENT-X, 2023, 17
  • [2] Source Fingerprints of Volatile Organic Compounds Emitted from A Municipal Solid Waste Incineration Power Plant in Guangzhou, China
    Liu, Shule
    Wang, Boguang
    He, Jie
    Tang, Xiaodong
    Luo, Wei
    Wang, Chen
    2011 INTERNATIONAL CONFERENCE OF ENVIRONMENTAL SCIENCE AND ENGINEERING, VOL 12, PT A, 2012, 12 : 106 - 115
  • [3] The Composition of Odor Compounds Emitted from Municipal Solid Waste Landfill
    Son, Youn-Suk
    Kim, Jo-Chun
    Kim, Ki-Hyung
    Lim, Bo-A
    Park, Kang-Nam
    Lee, Woo-Keun
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2007, 23 (06) : 666 - 674
  • [4] Pollution Characteristics and Evaluation of Heavy Metal Pollution in Surface Soil Around a Municipal Solid Waste Incineration Power Plant
    Lü Z.-L.
    Zhang J.-L.
    Lu S.-Y.
    Zou T.-S.
    Liu K.
    Zhang H.
    Gu Y.-Y.
    Huanjing Kexue/Environmental Science, 2019, 40 (05): : 2483 - 2492
  • [5] Design and evaluation of a municipal solid waste incineration power plant integrating with absorption heat pump
    Chen, Handing
    Guo, Shunzhi
    Song, Xudong
    He, Tianbiao
    ENERGY, 2024, 294
  • [6] Characteristics of Bottom Ash from Municipal Solid Waste Incineration
    Seniunaite, Jurgita
    Vasarevicius, Saulius
    Grubliauskas, Raimondas
    Zigmontiene, Ausra
    Vaitkus, Audrius
    ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 123 - 144
  • [7] Engineering characteristics of air pollution control residues from municipal solid waste incineration plant
    State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China
    Tongji Daxue Xuebao, 2007, 11 (1502-1506):
  • [8] Ammonia Emission Characteristics and Emission Factor of Municipal Solid Waste Incineration Plant
    Kang, Seongmin
    Woo, Jiyun
    Jeon, Eui-chan
    SUSTAINABILITY, 2020, 12 (18)
  • [9] VOCs released from municipal solid waste at the initial decomposition stage: Emission characteristics and an odor impact assessment
    Yanjun Liu
    Huiyuan Yang
    Wenjing Lu
    Journal of Environmental Sciences, 2020, (12) : 143 - 150
  • [10] VOCs released from municipal solid waste at the initial decomposition stage: Emission characteristics and an odor impact assessment
    Liu, Yanjun
    Yang, Huiyuan
    Lu, Wenjing
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2020, 98 : 143 - 150