Variation in cartilage T2 and T2*mapping of the wrist: a comparison between 3-and 7-T MRI

被引:5
|
作者
Heiss, Rafael [1 ]
Weber, Marc-Andre [2 ]
Balbach, Eva L. [1 ]
Hinsen, Maximilian [1 ]
Geissler, Frederik [1 ]
Nagel, Armin M. [1 ,3 ]
Ladd, Mark E. [3 ,4 ,5 ]
Arkudas, Andreas [6 ,7 ]
Horch, Raymund E. [6 ,7 ]
Gall, Christine [8 ]
Uder, Michael [1 ]
Roemer, Frank W. [1 ,9 ]
机构
[1] Univ Hosp Erlangen, Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Univ Med Ctr Rostock, Inst Diagnost & Intervent Radiol, Pediat Radiol & Neuroradiol, Schillingallee 35, D-18057 Rostock, Germany
[3] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[4] Heidelberg Univ, Fac Med, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[5] Heidelberg Univ, Fac Phys & Astron, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Plast & Hand Surg, Krankenhausstr 12, D-91054 Erlangen, Germany
[7] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Lab Tissue Engn & Regenerat Med, Krankenhausstr 12, D-91054 Erlangen, Germany
[8] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Informat Biometry & Epidemiol, Waldstr 6, D-91054 Erlangen, Germany
[9] Boston Univ, Sch Med, 72 E Concord St, Boston, MA 02118 USA
关键词
Cartilage (articular); Image processing (computer-assisted); Magnetic resonance imaging; Triangular fibrocartilage; Wrist joint; HUMAN ARTICULAR-CARTILAGE; GADOLINIUM-ENHANCED MRI; RELAXATION-TIME; MAGNETIC-RESONANCE; COIL; FIELD; OSTEOARTHRITIS; QUANTITATION; SEQUENCE;
D O I
10.1186/s41747-023-00394-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTo analyze regional variations in T2 and T2* relaxation times in wrist joint cartilage and the triangular fibrocartilage complex (TFCC) at 3 and 7 T and to compare values between field strengths.MethodsTwenty-five healthy controls and 25 patients with chronic wrist pain were examined at 3 and 7 T on the same day using T2- and T2*-weighted sequences. Six different regions of interest (ROIs) were evaluated for cartilage and 3 ROIs were evaluated at the TFCC based on manual segmentation. Paired t-tests were used to compare T2 and T2* values between field strengths and between different ROIs. Spearman's rank correlation was calculated to assess correlations between T2 and T2* time values at 3 and 7 T.ResultsT2 and T2* time values of the cartilage differed significantly between 3 and 7 T for all ROIs (p <= 0.045), with one exception: at the distal lunate, no significant differences in T2 values were observed between field strengths. T2* values differed significantly between 3 and 7 T for all ROIs of the TFCC (p <= 0.001). Spearman's rank correlation between 3 and 7 T ranged from 0.03 to 0.62 for T2 values and from 0.01 to 0.48 for T2* values. T2 and T2* values for cartilage varied across anatomic locations in healthy controls at both 3 and 7 T.ConclusionQuantitative results of T2 and T2* mapping at the wrist differ between field strengths, with poor correlation between 3 and 7 T. Local variations in cartilage T2 and T2* values are observed in healthy individuals.Relevance statementT2 and T2* mapping are feasible for compositional imaging of the TFCC and the cartilage at the wrist at both 3 and 7 T, but the clinical interpretation remains challenging due to differences between field strengths and variations between anatomic locations.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.Key points center dot Field strength and anatomic locations influence T2 and T2* values at the wrist.center dot T2 and T2* values have a poor correlation between 3 and 7 T.center dot Local reference values are needed for each anatomic location for reliable interpretation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Variation in cartilage T2 and T2* mapping of the wrist: a comparison between 3- and 7-T MRI
    Rafael Heiss
    Marc-André Weber
    Eva L. Balbach
    Maximilian Hinsen
    Frederik Geissler
    Armin M. Nagel
    Mark E. Ladd
    Andreas Arkudas
    Raymund E. Horch
    Christine Gall
    Michael Uder
    Frank W. Roemer
    European Radiology Experimental, 7
  • [2] Correction: Variation in cartilage T2 and T2* mapping of the wrist: a comparison between 3- and 7-T MRI
    Rafael Heiss
    Marc-André Weber
    Eva L. Balbach
    Maximilian Hinsen
    Frederik Geissler
    Armin M. Nagel
    Mark E. Ladd
    Andreas Arkudas
    Raymund E. Horch
    Christine Gall
    Michael Uder
    Frank W. Roemer
    European Radiology Experimental, 8
  • [3] Variation in cartilage T2 and T2* mapping of the wrist: a comparison between 3- and 7-T MRI (vol 7, 80, 2023)
    Heiss, Rafael
    Weber, Marc-Andre
    Balbach, Eva L.
    Hinsen, Maximilian
    Geissler, Frederik
    Nagel, Armin M.
    Ladd, Mark E.
    Arkudas, Andreas
    Horch, Raymund E.
    Gall, Christine
    Uder, Michael
    Roemer, Frank W.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [4] 7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers
    Andrea Lazik
    Jens M. Theysohn
    Christina Geis
    Sören Johst
    Mark E. Ladd
    Harald H. Quick
    Oliver Kraff
    European Radiology, 2016, 26 : 1245 - 1253
  • [5] 7 Tesla quantitative hip MRI: T1, T2 and T2☆ mapping of hip cartilage in healthy volunteers
    Lazik, Andrea
    Theysohn, Jens M.
    Geis, Christina
    Johst, Soeren
    Ladd, Mark E.
    Quick, Harald H.
    Kraff, Oliver
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1245 - 1253
  • [6] T2 and T2* Mapping
    Welsch G.H.
    Hennig F.F.
    Krinner S.
    Trattnig S.
    Current Radiology Reports, 2 (8)
  • [7] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [8] Morphological imaging and T2 and T2* mapping of hip cartilage at 7 Tesla MRI under the influence of intravenous gadolinium
    Andrea Lazik-Palm
    Oliver Kraff
    Christina Geis
    Sören Johst
    Juliane Goebel
    Mark E. Ladd
    Harald H. Quick
    Jens M. Theysohn
    European Radiology, 2016, 26 : 3923 - 3931
  • [9] Morphological imaging and T2 and T2*mapping of hip cartilage at 7 Tesla MRI under the influence of intravenous gadolinium
    Lazik-Palm, Andrea
    Kraff, Oliver
    Geis, Christina
    Johst, Soeren
    Goebel, Juliane
    Ladd, Mark E.
    Quick, Harald H.
    Theysohn, Jens M.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3923 - 3931
  • [10] The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions
    Juras, Vladimir
    Schreiner, Markus
    Laurent, Didier
    Zbyn, Stefan
    Mlynarik, Vladimir
    Szomolanyi, Pavol
    Hager, Benedikt
    Scotti, Celeste
    Goldhahn, Jorg
    Heule, Rahel
    Bieri, Oliver
    Trattnig, Siegfried
    MAGNETIC RESONANCE IMAGING, 2019, 55 : 86 - 92