Stability and accuracy improvement of element analysis in steel alloys using polarization-resolved laser-induced breakdown spectroscopy

被引:9
|
作者
Zhao, Shangyong [1 ]
Zhao, Yuchen [2 ]
Hou, Zongyu [1 ,3 ]
Wang, Zhe [1 ,3 ]
机构
[1] Tsinghua Univ, Dept Energy & Power Engn, Int Joint Lab Low Carbon Clean Energy Innovat, State Key Lab Energy Syst, Beijing 100084, Peoples R China
[2] Univ Nottingham Ningbo China, Nottingham Univ, Business Sch China, Ningbo 315100, Peoples R China
[3] Tsinghua Univ, Shanxi Res Inst Clean Energy, Taiyuan 030032, Peoples R China
基金
中国国家自然科学基金;
关键词
Polarization-resolved laser-induced breakdown; spectroscopy; Partial least squares; Relative standard deviation; Root-mean-square error; Signal-to-background ratio; SENSITIVITY; EMISSION;
D O I
10.1016/j.sab.2023.106666
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The existence of the background signal is one of the factors leading to the uncertainty of spectral intensity, which dramatically affects the stability, repeatability, and quantitative accuracy of laser-induced breakdown spec-troscopy (LIBS) measurements. In this work, the polarization-resolved LIBS (PR-LIBS) and partial least squares (PLS) regression models were proposed to improve the stability and accuracy of qualitative and quantitative analysis of steel alloy elements. The obtained spectra were pre-processed to select an appropriate number of variables, and the relationship between the spectral intensity and the certified concentration information of steel alloy samples was modeled using PLS. Compared to LIBS measurements, the relative standard deviation (RSD) and root-mean-square error (RMSE) of PR-LIBS decreased, while the signal-to-background ratio (SBR) and co-efficient of determination (R2) increased. Finally, the quantitative results of LIBS and PR-LIBS of Si, Mn, Cr, and Ni in steel alloy samples using PLS were displayed and discussed. For the PR-LIBS dataset, the R2 has increased by at least 3.4%, and the root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) have improved by at least 6.3% and 19.0%, respectively. These findings coupled with the simplicity of the experimental process indicate that PR-LIBS is a simple and low-cost solution that can increase the stability and accuracy of LIBS measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Polarization-resolved laser-induced breakdown spectroscopy
    Zhao, Youbo
    Singha, Sima
    Liu, Yaoming
    Gordon, Robert J.
    OPTICS LETTERS, 2009, 34 (04) : 494 - 496
  • [2] Nanosecond polarization-resolved laser-induced breakdown spectroscopy
    Liu, Yaoming
    Penczak, John S.
    Gordon, Robert J.
    OPTICS LETTERS, 2010, 35 (02) : 112 - 114
  • [3] Nanosecond and femtosecond polarization-resolved laser-induced breakdown spectroscopy of Al
    Penczak, John S.
    Liu, Yaoming
    Gordon, Robert J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [4] Optimization of copper detection based on polarization-resolved laser-induced breakdown spectroscopy
    Xu, Jiang
    Wang, Xiao
    Yao, Mingyin
    APPLIED OPTICS, 2021, 60 (17) : 5266 - 5270
  • [5] A comparison of single shot nanosecond and femtosecond polarization-resolved laser-induced breakdown spectroscopy of Al
    Nakimana Agnes
    陶海岩
    郝作强
    孙长凯
    高勋
    林景全
    Chinese Physics B, 2013, 22 (01) : 273 - 277
  • [6] A comparison of single shot nanosecond and femtosecond polarization-resolved laser-induced breakdown spectroscopy of Al
    Agnes, Nakimana
    Tao Hai-Yan
    Hao Zuo-Qiang
    Sun Chang-Kai
    Gao Xun
    Lin Jing-Quan
    CHINESE PHYSICS B, 2013, 22 (01)
  • [7] Polarization Resolved Laser-Induced Breakdown Spectroscopy of Al
    Penczak, John S.
    Liu, Yaoming
    Gordon, Robert J.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2009, 113 (47): : 13310 - 13317
  • [8] Improvement in classification accuracy of stainless steel alloys by laser-induced breakdown spectroscopy based on elemental intensity ratio analysis
    Shin, Sungho
    Moon, Youngmin
    Lee, Jaepil
    Kwon, Eunsung
    Park, Kyihwan
    Jeong, Sungho
    PLASMA SCIENCE & TECHNOLOGY, 2020, 22 (07)
  • [9] Improvement in classification accuracy of stainless steel alloys by laser-induced breakdown spectroscopy based on elemental intensity ratio analysis
    Sungho SHIN
    Youngmin MOON
    Jaepil LEE
    Eunsung KWON
    Kyihwan PARK
    Sungho JEONG
    Plasma Science and Technology, 2020, 22 (07) : 97 - 105
  • [10] Improvement in classification accuracy of stainless steel alloys by laser-induced breakdown spectroscopy based on elemental intensity ratio analysis
    Sungho SHIN
    Youngmin MOON
    Jaepil LEE
    Eunsung KWON
    Kyihwan PARK
    Sungho JEONG
    Plasma Science and Technology, 2020, (07) : 97 - 105