Fast Timing in Medical Imaging

被引:6
|
作者
Lecoq, P. [1 ,2 ,3 ]
Gonzalez, A. J. [2 ]
Auffray, E. [4 ]
Konstantinou, G. [1 ]
Nuyts, J. [5 ]
Prior, J. O. [6 ]
Turtos, R. M. [7 ]
Varela, J. [8 ]
机构
[1] Multiwave Metacrystal SA, CH-1228 Geneva, Switzerland
[2] Univ Politecn Valencia, Ctr Mixto, Inst Instrumentac Imagen Mol, CSIC, Valencia 46022, Spain
[3] European Org Nucl Res, CERN, CH-1211 Geneva, Switzerland
[4] European Org Nucl Res, DI Dept, CERN, CH-1211 Geneva, Switzerland
[5] Katholieke Univ Leuven, Nucl Med & Mol Imaging, MIRC, B-3000 Leuven, Belgium
[6] Lausanne Univ Hosp, Dept Nucl Med & Mol Imaging, CH-1011 Lausanne, Switzerland
[7] Aarhus Univ, Dept Phys & Astron, DK-8000 Aarhus, Denmark
[8] Univ Lisbon, LIP, P-1649004 Lisbon, Portugal
关键词
Biomedical imaging; Positron emission tomography; Timing; Imaging; Image reconstruction; Sensitivity; Crystals; Electronics; image reconstruction; medical imaging; metascintillator; photodetector; positron emission tomography (PET); scintillator heterostructure; scintillators; time-of-flight (TOF); COINCIDENCE-TIME-RESOLUTION; SCINTILLATION PROPERTIES; LUMINESCENCE; PERFORMANCE; DETECTORS; CRYSTALS; LIMITS; NOISE;
D O I
10.1109/TRPMS.2023.3259464
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report in this article on the Fast Timing in Medical Imaging workshop, (Valencia, 2 June 2022). The workshop gathered 104 attendees from all over the world, with representatives from the academic and industrial sectors. During three very dense days, nuclear medicine physicians, radiologists, oncologists, immunologists, and biologists have debated with physicists, engineers, technologists of different disciplines, as well as with medical imaging industry representatives to devise about the importance of improving the timing performance of a new generation of medical imaging instrumentation, with a special focus on positron emission tomography scanners toward the ultimate goal of 10-ps coincidence time resolution (CTR), allowing a millimeter 3-D spatial resolution on an event-to-event basis by time-of-flight (TOF) techniques. This article summarizes the most up-to-date developments on the roadmap toward the 10-ps time of flight challenge based on the contributions to this workshop.
引用
收藏
页码:429 / 452
页数:24
相关论文
共 50 条
  • [1] Recent developments in fast timing ASICs for particle physics and medical imaging
    Ahmad, S.
    Fleury, J.
    de la Taille, C.
    Seguin-Moreau, N.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (01):
  • [2] SAMPIC: a readout chip for fast timing detectors in particle physics and medical imaging
    Royon, Christophe
    APPLICATIONS OF NOVEL SCINTILLATORS FOR RESEARCH AND INDUSTRY (ANSRI 2015), 2015, 620
  • [3] Large area picosecond photodetector (LAPPD™) offers fast timing for nuclear physics and medical imaging
    Minot, M. J.
    Adams, B. W.
    Aviles, M. J.
    Butler, S.
    Ertley, C. D.
    Cremer, T.
    Foley, M. R.
    Hamel, C. J.
    Lyashenko, A., V
    Popecki, M. A.
    Rivera, T. W.
    Stochaj, M. E.
    Kwon, S., I
    Majewski, S.
    Cherry, S. R.
    Worstell, W. A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (01):
  • [4] Fast readout of GEM detectors for medical imaging
    Bucciantonio, M.
    Amaldi, U.
    Kieffer, R.
    Malakhov, N.
    Sauli, F.
    Watts, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 160 - 163
  • [5] A Fast Electromagnetic Solver for Microwave Medical Imaging
    Simonov, Nikolai
    Son, Seong-Ho
    Kim, Bo-Ra
    Lee, Kwang-Jae
    Jeon, Soon-Ik
    2014 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2014,
  • [6] Fast timing detectors with applications in cosmic ray physics and medical science
    Royon, Christophe
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [7] Fast timing detectors with applications in cosmic ray physics and medical science
    Royon, C.
    Gautier, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [8] Timing Resolution Study of an Associated Particle Detector for Fast Neutron Imaging
    Cates, J. W.
    Hayward, J. P.
    Zhang, X.
    Hausladen, P. A.
    Dabbs, B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1750 - 1756
  • [9] Fast and simple spectral FLIM for biochemical and medical imaging
    Popleteeva, Marina
    Haas, Kalina T.
    Stoppa, David
    Pancheri, Lucio
    Gasparini, Leonardo
    Kaminski, Clemens F.
    Cassidy, Liam D.
    Venkitaraman, Ashok R.
    Esposito, Alessandro
    OPTICS EXPRESS, 2015, 23 (18): : 23511 - 23525
  • [10] CUDA based Fast Bilateral Filter for Medical Imaging
    Oza, Shraddha
    Joshi, Kalyani R.
    2018 5TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2018, : 930 - 935