Benchmarking performance of an automatic polysomnography scoring system in a population with suspected sleep disorders

被引:9
|
作者
Choo, Bryan Peide [1 ]
Mok, Yingjuan [2 ,3 ]
Oh, Hong Choon [1 ,4 ,5 ]
Patanaik, Amiya [6 ]
Kishan, Kishan [6 ]
Awasthi, Animesh [7 ]
Biju, Siddharth [7 ]
Bhattacharjee, Soumya [8 ]
Poh, Yvonne [3 ]
Wong, Hang Siang [2 ,3 ]
机构
[1] Changi Gen Hosp, Hlth Serv Res, Singapore, Singapore
[2] Changi Gen Hosp, Dept Resp & Crit Care Med, Singapore, Singapore
[3] Changi Gen Hosp, Dept Sleep Med Surg & Sci, Singapore, Singapore
[4] Duke NUS Med Sch, Singapore, Singapore
[5] SingHealth Off Reg Hlth, Ctr Populat Hlth Res & Implementat, Singapore, Singapore
[6] Neurobit Inc, New York, NY USA
[7] Indian Inst Technol, Dept Biotechnol, Kharagpur, India
[8] Tata Inst Fundamental Res, Natl Ctr Biol Sci, Bengaluru, India
来源
FRONTIERS IN NEUROLOGY | 2023年 / 14卷
关键词
automatic sleep scoring; sleep-disordered breathing; machine learning; AI sleep scoring; sleep staging; AMERICAN ACADEMY; INTERRATER RELIABILITY; RESPIRATORY EVENTS; MEDICINE; AGREEMENT;
D O I
10.3389/fneur.2023.1123935
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
AimThe current gold standard for measuring sleep disorders is polysomnography (PSG), which is manually scored by a sleep technologist. Scoring a PSG is time-consuming and tedious, with substantial inter-rater variability. A deep-learning-based sleep analysis software module can perform autoscoring of PSG. The primary objective of the study is to validate the accuracy and reliability of the autoscoring software. The secondary objective is to measure workflow improvements in terms of time and cost via a time motion study. MethodologyThe performance of an automatic PSG scoring software was benchmarked against the performance of two independent sleep technologists on PSG data collected from patients with suspected sleep disorders. The technologists at the hospital clinic and a third-party scoring company scored the PSG records independently. The scores were then compared between the technologists and the automatic scoring system. An observational study was also performed where the time taken for sleep technologists at the hospital clinic to manually score PSGs was tracked, along with the time taken by the automatic scoring software to assess for potential time savings. ResultsPearson's correlation between the manually scored apnea-hypopnea index (AHI) and the automatically scored AHI was 0.962, demonstrating a near-perfect agreement. The autoscoring system demonstrated similar results in sleep staging. The agreement between automatic staging and manual scoring was higher in terms of accuracy and Cohen's kappa than the agreement between experts. The autoscoring system took an average of 42.7 s to score each record compared with 4,243 s for manual scoring. Following a manual review of the auto scores, an average time savings of 38.6 min per PSG was observed, amounting to 0.25 full-time equivalent (FTE) savings per year. ConclusionThe findings indicate a potential for a reduction in the burden of manual scoring of PSGs by sleep technologists and may be of operational significance for sleep laboratories in the healthcare setting.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Multi-modality of polysomnography signals' fusion for automatic sleep scoring
    Yan, Rui
    Zhang, Chi
    Spruyt, Karen
    Wei, Lai
    Wang, Zhiqiang
    Tian, Lili
    Li, Xueqiao
    Ristaniemi, Tapani
    Zhang, Jihui
    Cong, Fengyu
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 49 : 14 - 23
  • [2] Home (Level 2) polysomnography is feasible in children with suspected sleep disorders
    Russo, Kylie
    Greenhill, Janet
    Burgess, Scott
    SLEEP MEDICINE, 2021, 88 : 157 - 161
  • [3] An Automatic Sleep Scoring Toolbox: Multi-modality of Polysomnography Signals' Processing
    Yan, Rui
    Li, Fan
    Wang, Xiaoyu
    Ristaniemi, Tapani
    Cong, Fengyu
    PROCEEDINGS OF THE 16TH INTERNATIONAL JOINT CONFERENCE ON E-BUSINESS AND TELECOMMUNICATIONS, VOL 1: DCNET, ICE-B, OPTICS, SIGMAP AND WINSYS (ICETE), 2019, : 301 - 309
  • [4] Evaluating the performance of open-source and proprietary processing of actigraphy sleep estimation in children with suspected sleep disorders: a comparison with polysomnography
    Cepni, Aliye B.
    Burkart, Sarah
    Zhu, Xuanxuan
    White, James
    Finnegan, Olivia
    Nelakuditi, Srihari
    Beets, Michael
    Brown, David
    Pate, Russell
    Welk, Gregory
    de Zambotti, Massimiliano
    Ghosal, Rahul
    Wang, Yuan
    Armstrong, Bridget
    Adams, Elizabeth
    van Hees, Vincent
    Weaver, R. Glenn
    SLEEP, 2025,
  • [5] Utility of Technologist Editing of Polysomnography Scoring Performed by a Validated Automatic System
    Younes, Magdy
    Thompson, Wayne
    Leslie, Colleen
    Egan, Tanya
    Giannouli, Eleni
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2015, 12 (08) : 1206 - 1218
  • [6] Automatic sleep scoring in normals and in individuals with neurodegenerative disorders according to new international sleep scoring criteria
    Jensen, P.
    Sorensen, H. B. D.
    Jennum, P. J.
    EUROPEAN JOURNAL OF NEUROLOGY, 2010, 17 : 624 - 624
  • [7] Automatic Sleep Scoring in Normals and in Individuals With Neurodegenerative Disorders According to New International Sleep Scoring Criteria
    Jensen, Peter S.
    Sorensen, Helge B. D.
    Leonthin, Helle L.
    Jennum, Poul
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2010, 27 (04) : 296 - 302
  • [8] Performance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
    Malhotra, Atul
    Younes, Magdy
    Kuna, Samuel T.
    Benca, Ruth
    Kushida, Clete A.
    Walsh, James
    Hanlon, Alexandra
    Staley, Bethany
    Pack, Allan I.
    Pien, Grace W.
    SLEEP, 2013, 36 (04) : 573 - 582
  • [9] Development of a human-computer collaborative sleep scoring system for polysomnography recordings
    Liang, Sheng-Fu
    Shih, Yu-Hsuan
    Chen, Peng-Yu
    Kuo, Chih-En
    PLOS ONE, 2019, 14 (07):
  • [10] Automatic Sleep Scoring System Based On Autoregressive Model
    Melek, Mesut
    TIP TEKNOLOJILERI KONGRESI (TIPTEKNO'21), 2021,