A survey of patient compliance with removable orthodontic retainer wear in Brunei Darussalam

被引:1
|
作者
Lim, Meng Ern [1 ]
Dhaliwal, Jagjit Singh [1 ]
Abd Wahab, Siti Waznah Hj [1 ,2 ]
Rahman, Hanif Abdul [1 ]
机构
[1] Univ Brunei Darussalam, PAPRSB Inst Hlth Sci, Jalan Tungku Link, Gadong BE1410, Brunei
[2] Minist Hlth, Dept Dent Serv, Orthodont Unit, Jalan Lorong 1 Barat, Seria KB1133, Brunei
关键词
VACUUM-FORMED RETAINERS; RETENTION; HAWLEY;
D O I
10.1038/s41405-023-00138-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo explore compliance with removable orthodontic retainer wear among patients who had completed fixed appliance orthodontic treatments.Materials and methodsA cross-sectional online survey was distributed to patients who had completed orthodontic treatment at the government orthodontic clinics. The response rate was 54.9%, 663 questionnaires were distributed and 364 responses were received. Demographic information was collected, and questions regarding types of retainers prescribed, instructed and actual wear times, satisfaction levels, and reasons for wearing and not wearing retainers. Chi Square, Fisher's Exact tests and Independent T-Test were used to detect significant associations between variables.ResultsRespondents under 20 years old and employed were the most compliant. The mean satisfaction levels of Hawley Retainer and Vacuum-Formed Retainer were reported to be 3.7 (P = 0.565). About 28% of those in both groups stated that they wear them to maintain their teeth straight. 32.7% of Hawley retainer wearers reported not wearing their retainers due to speech difficulties.ConclusionAge and employment status were the variables that determined compliance. There was no significant difference in the satisfaction levels between the two retainer types. Most respondents wear their retainers to keep their teeth straight. Discomfort and forgetfulness were the primary reasons for not wearing retainers, besides speech difficulties.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A survey of patient compliance with removable orthodontic retainer wear in Brunei Darussalam
    Meng Ern Lim
    Jagjit Singh Dhaliwal
    Siti Waznah Hj Abd Wahab
    Hanif Abdul Rahman
    BDJ Open, 9
  • [2] Compliance with removable orthodontic appliancesQuestion: What is the level of compliance with removable orthodontic appliances?
    Nirmal Shah
    Evidence-Based Dentistry, 2017, 18 (4) : 105 - 106
  • [3] Retainer wear and compliance in the first 2 years after active orthodontic treatment
    Kacer, Kurtis A.
    Valiathan, Manish
    Narendran, Sena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (05) : 592 - 598
  • [4] Social perceptions of orthodontic retainer wear
    Meade, Maurice J.
    Millett, Declan T.
    Cronin, Michael
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (06) : 649 - 656
  • [5] CORRELATES OF OBJECTIVE PATIENT COMPLIANCE WITH REMOVABLE APPLIANCE WEAR
    BARTSCH, A
    WITT, E
    SAHM, G
    SCHNEIDER, S
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 104 (04) : 378 - 386
  • [6] Cleaning removable orthodontic appliances - a survey
    Eichenauer, Johanna
    Serbesis, Christos
    Ruf, Sabine
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2011, 72 (05): : 389 - +
  • [7] FACTORS ASSOCIATED WITH ORTHODONTIC PATIENT COMPLIANCE WITH INTRAORAL ELASTIC AND HEADGEAR WEAR
    EGOLF, RJ
    BEGOLE, EA
    UPSHAW, HS
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 97 (04) : 336 - 348
  • [8] Compliance monitor for use with removable orthodontic headgear appliances
    Department of Medical Electronics, St. Bartholomew's, Roy. London Sch. of Med. and Dent., Charterhouse Square, London EC1M 6BQ, United Kingdom
    MED. BIOL. ENG. COMPUT., 1 (57-60):
  • [9] Compliance monitor for use with removable orthodontic headgear appliances
    P. A. Kyriacou
    D. P. Jones
    Medical and Biological Engineering and Computing, 1997, 35 : 57 - 60
  • [10] Compliance monitor for use with removable orthodontic headgear appliances
    Kyriacou, PA
    Jones, DP
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) : 57 - 60