Reducing both radiation and contrast doses for overweight patients in coronary CT angiography with 80-kVp and deep learning image reconstruction

被引:4
|
作者
Li, Wanjiang [1 ]
Lu, Haiyan [2 ]
Wen, Yuting [1 ]
Zhou, Minggang [3 ]
Shuai, Tao [1 ]
You, Yongchun [1 ]
Zhao, Jin [1 ]
Liao, Kai [1 ]
Lu, Chunyan [1 ]
Li, Jianying [4 ]
Li, Zhenlin [1 ]
Diao, Kaiyue [1 ,5 ]
He, Yong [3 ,6 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Resp & Crit Care Med, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Cardiol, Chengdu, Sichuan, Peoples R China
[4] CT Res Ctr, GE Healthcare, Beijing, Peoples R China
[5] Sichuan Univ, West China Hosp, Dept Radiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[6] Sichuan Univ, West China Hosp, Dept Cardiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
关键词
Computed tomography; Coronary CT angiography; Radiation dose; Contrast dose; Deep -learning image reconstruction; TUBE VOLTAGE; ITERATIVE RECONSTRUCTION; SCCT GUIDELINES; QUALITY; OBESITY; RISK; BMI;
D O I
10.1016/j.ejrad.2023.110736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the use of an 80-kVp tube voltage combined with a deep learning image reconstruction (DLIR) algorithm in coronary CT angiography (CCTA) for overweight patients to reduce radiation and contrast doses in comparison with the 120-kVp protocol and adaptive statistical iterative reconstruction (ASIR-V). Methods: One hundred consecutive CCTA patients were prospectively enrolled and randomly divided into a low -dose group (n = 50) with 80-kVp, smart mA for noise index (NI) of 36 HU, contrast dose rate of 18 mgI/kg/s and DLIR and 60 % ASIR-V and a standard-dose group (n = 50) with 120-kVp, smart mA for NI of 25 HU, contrast dose rate of 32 mgI/kg/s and 60 % ASIR-V. The radiation and contrast dose, subjective image quality score, attenuation values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared. Results: The low-dose group achieved a significant reduction in the effective radiation dose (1.01 +/- 0.45 mSv vs 1.85 +/- 0.40 mSv, P < 0.001) and contrast dose (33.69 +/- 3.87 mL vs 59.11 +/- 5.60 mL, P < 0.001) compared to the standard-dose group. The low-dose group with DLIR presented similar enhancement but lower noise, higher SNR and CNR and higher subjective quality scores than the standard-dose group. Moreover, the same patient comparison in the low-dose group between different reconstructions showed that DLIR images had slightly and consistently higher CT values in small vessels, indicating better defined vessels, much lower image noise, higher SNR and CNR and higher subjective quality scores than ASIR-V images (all P < 0.001). Conclusions: The application of 80-kVp and DLIR allows for significant radiation and dose reduction while further improving image quality in CCTA for overweight patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Deep Learning Reconstruction Improves the Image Quality of CT Angiography Derived From 80-kVp Cerebral CT Perfusion Data
    Chen, Yu
    Wang, Yanling
    Su, Tong
    Xu, Min
    Yan, Jing
    Wang, Jian
    Liu, Haozhe
    Lu, Xiaoping
    Wang, Yun
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2023, 30 (11) : 2666 - 2673
  • [2] High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses
    Li, Wanjiang
    Diao, Kaiyue
    Wen, Yuting
    Shuai, Tao
    You, Yongchun
    Zhao, Jin
    Liao, Kai
    Lu, Chunyan
    Yu, Jianqun
    He, Yong
    Li, Zhenlin
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2912 - 2920
  • [3] High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses
    Wanjiang Li
    Kaiyue Diao
    Yuting Wen
    Tao Shuai
    Yongchun You
    Jin Zhao
    Kai Liao
    Chunyan Lu
    Jianqun Yu
    Yong He
    Zhenlin Li
    European Radiology, 2022, 32 : 2912 - 2920
  • [4] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55
  • [5] Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data
    Yang, Lin
    Zhang, Haiwei
    Sheng, Jiexin
    Wang, Meng
    Liu, Yaliang
    Xu, Min
    Yang, Xiao
    Wang, Bo
    He, Xiaolong
    Gao, Lei
    Zheng, Chao
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [6] Radiation Dose Reduction for 80-kVp Pediatric CT Using Deep Learning-Based Reconstruction: A Clinical and Phantom Study
    Nagayama, Yasunori
    Goto, Makoto
    Sakabe, Daisuke
    Emoto, Takafumi
    Shigematsu, Shinsuke
    Oda, Seitaro
    Tanoue, Shota
    Kidoh, Masafumi
    Nakaura, Takeshi
    Funama, Yoshinori
    Uchimura, Ryutaro
    Takada, Sentaro
    Hayashi, Hidetaka
    Hatemura, Masahiro
    Hirai, Toshinori
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (02) : 315 - 324
  • [7] Deep-learning image reconstruction for 80-kVp pancreatic CT protocol: Comparison of image quality and pancreatic ductal adenocarcinoma visibility with hybrid-iterative reconstruction
    Takai, Yukiko
    Noda, Yoshifumi
    Asano, Masashi
    Kawai, Nobuyuki
    Kaga, Tetsuro
    Tsuchida, Yuki
    Miyoshi, Toshiharu
    Hyodo, Fuminori
    Kato, Hiroki
    Matsuo, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [8] Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Cao, Yongli
    Zhou, Zuofu
    Li, Michelle
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (09) : 4162 - 4171
  • [9] 80-kVp hepatic CT to reduce contrast medium dose in azotemic patients: a feasibility study
    Holmquist, Fredrik
    Soderberg, Marcus
    Nyrnan, Ulf
    Falt, Tobias
    Siemund, Roger
    Geijer, Mats
    ACTA RADIOLOGICA, 2020, 61 (04) : 441 - 449
  • [10] Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol
    Yuhuan Chen
    Zhentang Liu
    Michelle Li
    Yong Yu
    Yongjun Jia
    Guangming Ma
    Zhijun Hu
    DongHong Wei
    Dou Li
    Taiping He
    European Radiology, 2019, 29 : 3036 - 3043