Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines

被引:1
|
作者
Piechota, Piotr [1 ]
Synowiec, Piotr [1 ]
Andruszkiewicz, Artur [1 ]
Wedrychowicz, Wieslaw [1 ]
Wroblewska, Elzbieta [1 ]
Mrowiec, Andrzej [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Mech & Power Engn, Dept Thermal Sci, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
[2] Calis Univ, Polytech Fac, PL-62800 Kalisz, Poland
关键词
ultrasonic flow meter; clamp-on; flow disturbance; correction factor measurement error; knife gate valve; laser doppler anemometry; SIMULATION; GAS;
D O I
10.3390/s23104677
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3-15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve's closure: 1/3 and 1/2 of the valve's height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.
引用
收藏
页数:28
相关论文
共 7 条
  • [1] Influence of Flow Disturbances behind the 90° Bend on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
    Synowiec, Piotr
    Andruszkiewicz, Artur
    Wedrychowicz, Wieslaw
    Piechota, Piotr
    Wroblewska, Elzbieta
    SENSORS, 2021, 21 (03) : 1 - 23
  • [2] Installation Effects of a Clamp-On Transit Time Ultrasonic Flow Meter
    Kumar, K.
    Farande, K. U.
    Sahoo, G. C.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2011, 38 (06) : 489 - 498
  • [3] A clamp-on ultrasonic cross correlation flow meter for one-phase flow
    Worch, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 622 - 630
  • [4] Studies on the transducers of Clamp-on Transit-time Ultrasonic Flow meter
    Han, Jianping
    Liu, Hao
    Zhou, Yuanyuan
    Zhang, Rumei
    Li, Changji
    2014 4TH IEEE INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND TECHNOLOGY (ICIST), 2014, : 180 - 183
  • [5] High-temperature flow measurement with wetted and clamp-on ultrasonic sensors
    Lynnworth, Larry
    Sensors (Peterborough, NH), 1999, 16 (10): : 40 - 42
  • [6] Measurement of Pipe and Fluid Properties With a Matrix Array-Based Ultrasonic Clamp-On Flow Meter
    Massaad, Jack
    van Neer, Paul L. M. J.
    van Willigen, Douwe M.
    Sabbadini, Alberico
    de Jong, Nicolaas
    Pertijs, Michiel A. P.
    Verweij, Martin D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (01) : 309 - 322