Disposable paper-based screen-printed electrochemical immunoplatform for dual detection of esophageal cancer biomarkers in patients' serum samples

被引:4
|
作者
Verma, Damini [1 ]
Dubey, Neha [1 ]
Yadav, Amit K. [1 ]
Saraya, Anoop [3 ]
Sharma, Rinu [2 ]
Solanki, Pratima R. [1 ]
机构
[1] Jawaharlal Nehru Univ, Special Ctr Nanosci, Nanobio Lab, New Delhi, India
[2] Guru Gobind Singh Indraprastha Univ, Univ Sch Biotechnol, New Delhi, India
[3] All India Inst Med Sci, Dept Gastroenterol, Ansari Nagar, New Delhi, India
来源
MATERIALS ADVANCES | 2024年 / 5卷 / 05期
关键词
CARBON-BLACK; P53; PROTEIN; CYFRA; 21-1; ELECTRODES; BIOSENSORS; SENSOR; SMART;
D O I
10.1039/d3ma00438d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Esophageal cancer is an aggressive disease with an extremely poor prognosis. However, early detection and timely treatment improve the chances of survival. Therefore, in this study, disposable, low-cost, flexible, reagentless, and highly sensitive paper-based screen-printed electrochemical immunosensors were developed for the dual determination of cytokeratin fragment 21-1 (CYFRA-21-1) and tumor protein (TP53) biomarkers in patient serum samples. For this, graphite ink was prepared with the help of a screen-printing machine, a in homepaper-based screen-printed electrode (SPE) substrate was fabricated on its surface. The immobilization of antibodies (CYFRA21-1 and TP53, individually) and BSA were done on inhome paper-based SPE directly using the drop-cast method. The paper-based SPE and other immunoelectrodes were characterized using Fourier transform infrared (FT-IR) spectroscopy, contact angle, scanning electron microscopy (SEM), and energy dispersive X-ray (EDX) spectroscopy. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were employed as electrochemical methods for evaluating the performances of immunoplatforms. Under the optimized conditions, the immunoplatforms exhibited a wide linear range for CYFRA21-1 and TP53 from 0.1 to 25 ng mL-1 and 0.001-10 ng mL-1, respectively. Comparatively, TP53 showed better results in terms of sensitivity [222.62 mu A (log10 ng mL-1 cm-2)-1], the limit of quantification (LOQ) [0.018 ng mL-1], and the limit of detection (LOD) [0.005 ng mL-1] in contrast to CYFRA21-1 (sensitivity, 167.07 mu A (log10 ng mL-1 cm-2)-1; LOQ, 0.041 ng mL-1; and LOD, 0.012 ng mL-1). Thus, the developed immunosensors could potentially be applied as biodevices in clinical laboratories or employed for detecting cancer biomarkers in different human fluids since this method is sensitive, uncomplicated, affordable, portable, and straightforward to develop. A schematic illustration of the fabrication of disposable paper-based screen-printed electrochemical immunoplatforms for dual detection of esophageal cancer biomarkers in patient serum samples.
引用
收藏
页码:2153 / 2168
页数:16
相关论文
共 50 条
  • [1] Disposable paper-based electrochemical sensor utilizing inkjet-printed Polyaniline modified screen-printed carbon electrode for Ascorbic acid detection
    Kit-Anan, Worrapong
    Olarnwanich, Aricha
    Sriprachuabwong, Chakrit
    Karuwan, Chanpen
    Tuantranont, Adisorn
    Wisitsoraat, Anurat
    Srituravanich, Werayut
    Pimpin, Alongkorn
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 685 : 72 - 78
  • [2] Screen-printed Electrochemical Immunosensors for the Detection of Cancer and Cardiovascular Biomarkers
    Costa Rama, Estefania
    Costa-Garcia, Agustin
    ELECTROANALYSIS, 2016, 28 (08) : 1700 - 1715
  • [3] Fully Screen-printed Paper-based Electrode Chip for Glucose Detection
    Shitanda, Isao
    Yamaguchi, Tasuku
    Hoshi, Yoshinao
    Itagaki, Masayuki
    CHEMISTRY LETTERS, 2013, 42 (11) : 1369 - 1370
  • [4] Novel reagentless paper-based screen-printed electrochemical sensor to detect phosphate
    Cinti, Stefano
    Talarico, Daria
    Palleschi, Giuseppe
    Moscone, Danila
    Arduini, Fabiana
    ANALYTICA CHIMICA ACTA, 2016, 919 : 78 - 84
  • [5] Disposable screen-printed sensors for the electrochemical detection of TNT and DNT
    Caygill, J. Sarah
    Collyer, Stuart D.
    Holmes, Joanne L.
    Davis, Frank
    Higson, Seamus P. J.
    ANALYST, 2013, 138 (01) : 346 - 352
  • [6] Electrochemical detection of NOx gas based on disposable paper-based analytical device using a copper nanoparticles-modified screen-printed graphene electrode
    Pungjunun, Kingkan
    Chaiyo, Sudkate
    Praphairaksit, Narong
    Siangproh, Weena
    Ortner, Astrid
    Kalcher, Kurt
    Chailapakul, Orawon
    Mehmeti, Eda
    BIOSENSORS & BIOELECTRONICS, 2019, 143
  • [7] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine
    Yong Yao
    Chunsun Zhang
    Biomedical Microdevices, 2016, 18
  • [8] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine
    Yao, Yong
    Zhang, Chunsun
    BIOMEDICAL MICRODEVICES, 2016, 18 (05)
  • [9] Electrochemical Sensor for Bilirubin Detection Using Paper-Based Screen-Printed Electrodes Functionalized with Silver Nanoparticles
    Anzar, Nigar
    Suleman, Shariq
    Kumar, Rocky
    Rawal, Rachna
    Pundir, Chandra Shekhar
    Pilloton, Roberto
    Narang, Jagriti
    MICROMACHINES, 2022, 13 (11)
  • [10] Development of aptasensor for chlorpyrifos detection using paper-based screen-printed electrode
    Himanshu, Jayendra Kumar
    Lakshmi, G. B. V. S.
    Verma, Awadhesh Kumar
    Ahlawat, Amit
    Solanki, Pratima R.
    ENVIRONMENTAL RESEARCH, 2024, 240