Electrochemical sensors for simultaneous detection of dopamine and uric acid based on a composite of electrochemically reduced graphene oxide and PEDOT:PSS-modified glassy carbon electrode

被引:18
|
作者
Ta'alia, Shafa Aini Hasnawati [1 ]
Rohaeti, Eti [1 ]
Putra, Budi Riza [2 ]
Wahyuni, Wulan Tri [1 ,3 ]
机构
[1] IPB Univ, Fac Math & Nat Sci, Dept Chem, Analyt Chem Div, Bogor, Indonesia
[2] Natl Res & Innovat Agcy BRIN, Res Ctr Met, PUSPIPTEK Gd 470, South Tangerang, Banten, Indonesia
[3] IPB Univ, Inst Res & Community Empowerment, Trop Biopharmaca Res Ctr, Bogor, Indonesia
关键词
Reduced graphene oxide; PEDOT; PSS; Uric acid; Dopamine; Simultaneous detection; ASCORBIC-ACID; REDUCTION; NANOPARTICLES; FILMS;
D O I
10.1016/j.rechem.2023.101024
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein, we report the development of a successful electrochemical sensor based on a composite of electrochemically reduced graphene oxide (ErGO) and poly(3,4-ethylenedioxythiophene):poly(styrene-4-sulphonate) (PEDOT:PSS) for the simultaneous detection of dopamine (DA) and uric acid (UA). A glassy carbon electrode was modified with a composite of ErGO and PEDOT:PSS and further characterized using Raman spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), and electrochemical impedance spectroscopy. The obtained composition of weight ratio between ErGO and PEDOT:PSS as 7:3 demonstrated the highest electrocatalytic activity for the simultaneous detection of DA and UA when it was investigated using differential pulse voltammetry technique under optimized experimental conditions. The developed sensor also exhibited two separate well-defined anodic peaks of both analytes with a linear response over the concentration range of 3-33 & mu;M for DA and 10-110 & mu;M for UA. The limits of detection for DA and UA were 0.4 and 0.5 & mu;M, respectively. The proposed sensor also displayed good stability and reproducibility for the simultaneous detection of DA and UA for five consecutive days of measurements. In addition, the developed sensor exhibited a good selectivity for the simultaneous detection of DA and UA against several potential interferences, such as K+, Cl-, C2O42, PO43 � , ascorbic acid, glucose, and urea, with % recovery values of 97%-101% for DA and 97%-103% for UA, which are acceptable in the analytical range. Furthermore, this sensor was successfully used in detecting DA and UA in real human samples using standard addition techniques and thus may have a potency to be further employed in practical applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A facile electrochemical sensor based on a composite of electrochemically reduced graphene oxide and a PEDOT:PSS modified glassy carbon electrode for uric acid detection
    Budi R. Putra
    Ulfiatun Nisa
    Rudi Heryanto
    Eti Rohaeti
    Munawar Khalil
    Arini Izzataddini
    Wulan T. Wahyuni
    Analytical Sciences, 2022, 38 : 157 - 166
  • [2] A facile electrochemical sensor based on a composite of electrochemically reduced graphene oxide and a PEDOT:PSS modified glassy carbon electrode for uric acid detection
    Putra, Budi R.
    Nisa, Ulfiatun
    Heryanto, Rudi
    Rohaeti, Eti
    Khalil, Munawar
    Izzataddini, Arini
    Wahyuni, Wulan T.
    ANALYTICAL SCIENCES, 2022, 38 (01) : 157 - 166
  • [3] Electrochemical sensors based on the composite of reduced graphene oxide and a multiwalled carbon nanotube-modified glassy carbon electrode for simultaneous detection of hydroquinone, dopamine, and uric acid
    Wahyuni, Wulan Tri
    Hasnawati Ta'alia, Shafa Aini
    Akbar, Ari Yustisia
    Elvira, Bunga Rani
    Irkham, Isnaini
    Rahmawati, Isnaini
    Wahyuono, Ruri Agung
    Putra, Budi Riza
    RSC ADVANCES, 2024, 14 (38) : 27999 - 28016
  • [4] Electrochemical Sensors Based on a Composite of Electrochemically Reduced Graphene Oxide and PEDOT:PSS for Hydrazine Detection
    Rahman, Hemas Arif
    Rafi, Mohamad
    Putra, Budi Riza
    Wahyuni, Wulan Tri
    ACS OMEGA, 2023, 8 (03): : 3258 - 3269
  • [5] A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid
    Yu, Joonhee
    Kim, Tae Hyun
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2017, 8 (04) : 274 - 281
  • [6] Electrochemical sensor based on graphene oxide/PEDOT:PSS composite modified glassy carbon electrode for environmental nitrite detection
    Anindya, Weni
    Wahyuni, Wulan Tri
    Rafi, Mohamad
    Putra, Budi Riza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (03):
  • [7] A facile electrochemical sensor based on reduced graphene oxide and Au nanoplates modified glassy carbon electrode for simultaneous detection of ascorbic acid, dopamine and uric acid
    Wang, Caiqin
    Du, Jiao
    Wang, Huiwen
    Zou, Cui'e
    Jiang, Fengxing
    Yang, Ping
    Du, Yukou
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 302 - 309
  • [8] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Yong Kong
    Xiaolin Ren
    Zongli Huo
    Guoxin Wang
    Yongxin Tao
    Chao Yao
    European Food Research and Technology, 2013, 236 : 955 - 961
  • [9] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961
  • [10] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    SENSORS, 2014, 14 (08): : 15227 - 15243