Creating patient-specific digital phantoms with a longitudinal atlas for evaluating deformable CT-CBCT registration in adaptive lung radiotherapy

被引:1
|
作者
Meyer, Sebastian [1 ]
Alam, Sadegh [1 ]
Kuo, Li Cheng [1 ]
Hu, Yu-Chi [1 ]
Liu, Yilin [1 ]
Lu, Wei [1 ]
Yorke, Ellen [1 ]
Li, Anyi [1 ]
Cervino, Laura [1 ]
Zhang, Pengpeng [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 633 3rd Ave,5th Floor,5SH9, New York, NY 10017 USA
关键词
adaptive radiotherapy; deformable image registration; longitudinal atlas; IMAGE REGISTRATION; ALGORITHMS; UNCERTAINTIES; VOLUME;
D O I
10.1002/mp.16606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuality assurance of deformable image registration (DIR) is challenging because the ground truth is often unavailable. In addition, current approaches that rely on artificial transformations do not adequately resemble clinical scenarios encountered in adaptive radiotherapy. PurposeWe developed an atlas-based method to create a variety of patient-specific serial digital phantoms with CBCT-like image quality to assess the DIR performance for longitudinal CBCT imaging data in adaptive lung radiotherapy. MethodsA library of deformations was created by extracting the longitudinal changes observed between a planning CT and weekly CBCT from an atlas of lung radiotherapy patients. The planning CT of an inquiry patient was first deformed by mapping the deformation pattern from a matched atlas patient, and subsequently appended with CBCT artifacts to imitate a weekly CBCT. Finally, a group of digital phantoms around an inquiry patient was produced to simulate a series of possible evolutions of tumor and adjacent normal structures. We validated the generated deformation vector fields (DVFs) to ensure numerically and physiologically realistic transformations. The proposed framework was applied to evaluate the performance of the DIR algorithm implemented in the commercial Eclipse treatment planning system in a retrospective study of eight inquiry patients. ResultsThe generated DVFs were inverse consistent within less than 3 mm and did not exhibit unrealistic folding. The deformation patterns adequately mimicked the observed longitudinal anatomical changes of the matched atlas patients. Worse Eclipse DVF accuracy was observed in regions of low image contrast or artifacts. The structure volumes exhibiting a DVF error magnitude of equal or more than 2 mm ranged from 24.5% (spinal cord) to 69.2% (heart) and the maximum DVF error exceeded 5 mm for all structures except the spinal cord. Contour-based evaluations showed a high degree of alignment with dice similarity coefficients above 0.8 in all cases, which underestimated the overall DVF accuracy within the structures. ConclusionsIt is feasible to create and augment digital phantoms based on a particular patient of interest using multiple series of deformation patterns from matched patients in an atlas. This can provide a semi-automated procedure to complement the quality assurance of CT-CBCT DIR and facilitate the clinical implementation of image-guided and adaptive radiotherapy that involve longitudinal CBCT imaging studies.
引用
收藏
页码:1405 / 1414
页数:10
相关论文
共 31 条
  • [1] Virtual CT for adaptive prostate radiotherapy based on CT-CBCT deformable image registration
    Cassetta Junior, F. R.
    Ciardo, D.
    Fattori, G.
    Riboldi, M.
    Orecchia, R.
    Jereczek-Fossa, B. A.
    Baroni, G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S902 - S903
  • [2] Head-And-Neck Digital Phantoms for Geometric and Dosimetric Uncertainty Evaluation of CT-CBCT Deformable Image Registration
    Shen, Z.
    Bzdusek, K.
    Koyfman, S.
    Xia, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3292 - 3292
  • [3] Patient-Specific Quality Assurance of Deformable Image Registrations Using Atlas for Adaptive Radiotherapy of Lung Cancer
    Alam, S. R.
    Meyer, S.
    Kuo, L.
    Hu, Y. C.
    Lu, W.
    Yorke, E. D.
    Rimner, A.
    Cervino, L. I.
    Zhang, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E582 - E582
  • [4] Using patient-specific phantoms to evaluate deformable image registration algorithms for adaptive radiation therapy
    Stanley, Nick
    Glide-Hurst, Carri
    Kim, Jinkoo
    Adams, Jeffrey
    Li, Shunshan
    Wen, Ning
    Chetty, Indrin J.
    Zhong, Hualiang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 177 - 194
  • [5] A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy
    Liu, C.
    Kumarasiri, A.
    Chetvertkov, M.
    Gordon, J.
    Chetty, I.
    Siddiqui, F.
    Kim, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3290 - 3291
  • [6] Evaluating the Quality of Patient-Specific Deformable Image Registration in Adaptive Radiotherapy Using a Digitally Enhanced Head and Neck Phantom
    Cagni, Elisabetta
    Botti, Andrea
    Orlandi, Matteo
    Galaverni, Marco
    Iotti, Cinzia
    Iori, Mauro
    Lewis, Geraint
    Spezi, Emiliano
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [7] A Patient-Specific Approach for Estimating the Voxel-Level Uncertainty Distribution of Deformable Image Registration in Adaptive Radiotherapy
    Meyer, S.
    Alam, S.
    Kuo, L.
    Hu, Y.
    Cervino, L.
    Zhang, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E323 - E323
  • [8] SBRT Patient Specific QA: Adaptive dose accumulation from deformable CBCT image registration
    Vestergaard, S. B.
    Nielsen, M. S.
    Kjeldsen, R.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1266 - S1267
  • [9] Patient-Specific CBCT to Synthetic CT Translation Network for Online Adaptive Proton Therapy
    Lv, T.
    Fang, C.
    Zhang, Y.
    Zhang, G.
    Li, X.
    Zhao, W.
    Xu, S., Sr.
    Li, N.
    MEDICAL PHYSICS, 2024, 51 (10) : 7679 - 7679