Impact of Carotid Stent Design on Embolic Filter Debris Load During Carotid Artery Stenting

被引:11
|
作者
Squizzato, Francesco [1 ,3 ]
Piazza, Michele [1 ]
Forcella, Edoardo [1 ]
Colacchio, Elda Chiara [1 ]
Fedrigo, Marny [2 ]
Angelini, Annalisa [2 ]
Grego, Franco [1 ]
Antonello, Michele [1 ]
机构
[1] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Sect Vasc & Endovascular Surg, Padua, Italy
[2] Univ Padua, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Sect Cardio Thorac & Vasc Pathol, Padua, Italy
[3] Padova Univ, Sch Med, Vasc & Endovascular Surg Div, Via Giustiniani 2, I-35100 Padua, Italy
关键词
carotid artery; carotid stenosis; patients; risk; stent; stroke; EXPERIENCE; STROKE;
D O I
10.1161/STROKEAHA.123.043117
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The carotid stent design may influence the risk of embolization during carotid artery stenting. The aim of the study was to assess this risk by comparing the quantity of embolized material captured by filters during carotid artery stenting, using different stent designs. METHODS: We conducted a single-center retrospective study of patients undergoing carotid artery stenting for asymptomatic carotid stenosis >70% (2010-2022) in a tertiary academic hospital (Padua University Hospital, Italy). Carotid stents were classified according to their design as open-cell (OCS), closed-cell (CCS), or micromesh stents (MMS). A distal filter protection was used in all patients, and the amount of captured embolized particles was semiautomatically analyzed using a dedicated software (Image-Pro Plus, Media Cybernetics). Primary end point was embolic filter debris (EFD) load, defined as the ratio of the filter area covered by particulate material to the total filter area. Secondary end points were 30 days major stroke and death. RESULTS: Four-hundred-eighty-one carotid artery stentings were included; 171 (35%) using an OCS, 68 (14%) a CCS, and 242 (50%) a MMS. Thirty-days mortality was 0.2% (n=1) and major stroke rate was 0.2% (P=0.987). Filters of patients receiving MMS were more likely to be free from embolized material (OCS, 30%; CCS, 13%; MMS, 41%; P<0.001) and had a lower EFD load (OCS, 9.1 +/- 14.5%; CCS, 7.9 +/- 14.0%; MMS, 5.0 +/- 9.1%; P<0.001) compared with other stent designs. After stratification by plaque characteristics, MMS had a lower EFD load in cases of hypoechogenic plaque (OCS, 13.4 +/- 9.9%; CCS, 10.9 +/- 8.7%; MMS, 6.5 +/- 13.1%; P<0.001), plaque length>15 mm (OC, 10.2 +/- 15.3; CC, 8.6 +/- 12.4; MM, 8.2 +/- 13.6; P<0.001), and preoperative ipsilateral asymptomatic ischemic cerebral lesion (OCS, 12.9 +/- 16.8%; CCS, 8.7 +/- 19.5%; MMS, 5.4 +/- 9.7%; P<0.001). After multivariate linear regression, use of MMS was associated with lower EFD load (P=0.038). CONCLUSIONS: The use of MMS seems to be associated with a lower embolization rate and EFD load, especially in hypoechogenic and long plaques and in patients with a preoperative evidence of asymptomatic ischemic cerebral lesion.
引用
收藏
页码:2534 / 2541
页数:8
相关论文
共 50 条
  • [1] Quantitative Analysis and Predictors of Embolic Filter Debris Load During Carotid Artery Stenting in Asymptomatic Patients
    Piazza, Michele
    Squizzato, Francesco
    Chincarini, Chiara
    Angelini, Annalisa
    Lepidi, Sandra
    Grego, Franco
    Antonello, Michele
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 5S - 5S
  • [2] Quantitative analysis and predictors of embolic filter debris load during carotid artery stenting in asymptomatic patients
    Brothers, Thomas E.
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (01) : 135 - 136
  • [3] A Microscopic and Biomarker Evaluation of Embolic Filter Debris Collected During Carotid Artery Stenting
    Yang, Mark
    Yu, Yan
    Walsh, William R.
    Yang, Jia-Lin
    Baker, Luke
    Lennox, Andrew F.
    Crowe, Philip J.
    Varcoe, Ramon L.
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (02) : 275 - 284
  • [4] Pathology of embolic debris in carotid artery stenting
    Matsukawa, H.
    Fujii, M.
    Uemura, A.
    Suzuki, K.
    Yamamoto, D.
    Takahashi, O.
    Niimi, Y.
    ACTA NEUROLOGICA SCANDINAVICA, 2015, 131 (04): : 197 - 202
  • [5] A Comparative Quantitative Analysis of Embolic Filter Debris Load During Carotid Artery Stenting, Between Open Cell, Closed Cell and Micromesh Stents
    Piazza, Michele
    Squizzato, Francesco
    Chincarini, Chiara
    Fedrigo, Marny
    Angelini, Annalisa
    Grego, Franco
    Antonello, Michele
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E65 - E65
  • [6] A Comparative Quantitative Analysis of Embolic Filter Debris Load During Carotid Artery Stenting Between Open-Cell, Closed-Cell, and Micromesh
    Antonello, Michele
    Squizzato, Francesco
    Xodo, Andrea
    Chincarini, Chiara
    Grego, Franco
    Piazza, Michele
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E166 - E167
  • [7] Flow impairment during protected carotid artery stenting: Impact of filter device design
    Roffi, Marco
    Greutmann, Matthias
    Schwarz, Urs
    Luscher, Thomas F.
    Eberli, Franz R.
    Amann-Vesti, Beatrice
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (01) : 103 - 109
  • [8] Carotid embolic filter devices: The latest advance in carotid stenting
    Roubin, GS
    Iyer, SS
    Vitek, JJ
    JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (01): : 110 - 110
  • [9] Distal flow protection during carotid stenting: A prospective study to quantify the embolic debris retrieved in the internal carotid artery territory
    Martin, J
    Gailloud, P
    Khan, HG
    Guimaraens, L
    Theron, JG
    Ruefenacht, DA
    RADIOLOGY, 1998, 209P : 474 - 474
  • [10] Entrapment of an embolic protection device within stent during carotid artery stenting: a case report
    Hyun Jin Kim
    Sanghyeon Kim
    Myongjin Kang
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 59