A CUFFLESS BLOOD PRESSURE MONITORING EPIDERMAL PATCH ENABLED BY DEEP LEARNING

被引:0
|
作者
Sharma, Sudeep [1 ]
Pradhan, Gagan Bahadur [1 ]
Jeong, Seonghoon [1 ]
Park, Jae Yeong [1 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, Seoul, South Korea
关键词
Epidermal patch; cuffless blood pressure monitoring; ballistocardiogram; electrocardiogram; deep learning;
D O I
10.1109/MEMS58180.2024.10439507
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a wrist-wearable epidermal patch comprising a piezoresistive ballistocardiogram (BCG) and an electrocardiogram (ECG) sensor for continuous and cuffless blood pressure (BP) monitoring has been developed and demonstrated. Specially designed electrode patterns were printed onto a flexible PET substrate for miniaturization and multimodal sensing. The BCG sensor showed a high sensitivity of -0.093 kPa(-1) at a low-pressure range (0-5 kPa). Simultaneous measurement allowed BP estimations through Convolutional Neural Network - Long Short-Term Memory (CNN-LSTM) based deep learning algorithm with an accuracy of MAE 7.798 for DBP and 3.540 for SBP which eliminated the need for traditional cuff-based systems.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 50 条
  • [1] Cuffless Blood Pressure Monitoring
    Abbasi, Jennifer
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2019, 322 (14): : 1343 - 1343
  • [2] Deep learning models for cuffless blood pressure monitoring from PPG signals using attention mechanism
    El-Hajj, C.
    Kyriacou, P. A.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 65
  • [3] Deep learning models for cuffless blood pressure monitoring from PPG signals using attention mechanism
    El-Hajj, C.
    Kyriacou, P.A.
    Biomedical Signal Processing and Control, 2021, 65
  • [4] Cuffless Blood Pressure Monitoring Promises and Challenges
    Pandit, Jay A.
    Lores, Enrique
    Batlle, Daniel
    CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 15 (10): : 1531 - 1538
  • [5] A hydrostatic pressure approach to cuffless blood pressure monitoring
    Shaltis, P
    Reisner, A
    Asada, H
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2173 - 2176
  • [6] The reality and serendipity of cuffless blood pressure monitoring
    Alberto Avolio
    Hypertension Research, 2023, 46 : 1609 - 1611
  • [7] The reality and serendipity of cuffless blood pressure monitoring
    Avolio, Alberto
    HYPERTENSION RESEARCH, 2023, 46 (06) : 1609 - 1611
  • [8] Cuffless Deep Learning-Based Blood Pressure Estimation for Smart Wristwatches
    Song, Kwangsub
    Chung, Ku-young
    Chang, Joon-Hyuk
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4292 - 4302
  • [9] Continual learning for cuffless blood pressure estimation
    Zhang, Chunlin
    Wang, Wenyan
    Song, Xinyue
    Lin, Yuxuan
    Chen, Yifan
    Ding, Xiaorong
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 92
  • [10] Cuffless blood pressure monitoring using hydrostatic pressure changes
    Shaltis, Phillip A.
    Reisner, Andrew T.
    Asada, H. Harry
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (06) : 1775 - 1777