The effects of video double-lumen tubes on intubation complications in patients undergoing thoracic surgery

被引:4
|
作者
Shui, Weikang [1 ]
Hu, Wei [1 ]
Ma, Wenwen [2 ]
Han, Yuting [2 ]
Hao, Ian Yifei [3 ]
Zhu, Shiyao [1 ]
Sun, Yuefeng [1 ]
Deng, Zhijie [1 ]
Gao, Ya [4 ]
Heng, Lei [2 ]
Zhu, Shanshan [2 ,5 ,6 ]
机构
[1] Xuzhou Med Univ, Jiangsu Prov Key Lab Anaesthesiol, Xuzhou, Peoples R China
[2] Xuzhou Canc Hosp, Dept Anaesthesiol, Xuzhou, Peoples R China
[3] Calif State Univ, Los Angeles, CA USA
[4] Jiangsu Univ, Zhenjiang, Jiangsu, Peoples R China
[5] Xuzhou Med Univ, Xuzhou 221004, Peoples R China
[6] Xuzhou Canc Hosp, Dept Anaesthesiol, Xuzhou 221005, Jiangsu, Peoples R China
关键词
POSTOPERATIVE SORE THROAT; ENDOBRONCHIAL INTUBATION; FIBEROPTIC BRONCHOSCOPY; INJURIES; BLOCKER;
D O I
10.1097/EJA.0000000000001959
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUNDTracheal injuries, vocal cord injuries, sore throat and hoarseness are common complications of double-lumen tube (DLT) intubation.OBJECTIVEThis study aimed to evaluate the effects of 'video double-lumen tubes' (VDLTs) on intubation complications in patients undergoing thoracic surgery.DESIGNA randomised controlled study.SETTINGTXuzhou Cancer Hospital, Xuzhou, China, from January 2023 to June 2023.PATIENTSOne hundred eighty-two patients undergoing elective thoracic surgery with one-lung ventilation were randomised into two groups: 90 in the DLT group and 92 in the VDLT group.INTERVENTIONVDLT was selected for intubation in the VDLT group, and DLT was selected for intubation in the DLT group. A fibreoptic bronchoscope (FOB) was used to record tracheal and vocal cord injuries.MAIN OUTCOME MEASURESThe primary outcomes were the incidence of moderate-to-severe tracheal injury and the incidence of vocal cord injury. The secondary outcomes included the incidence and severity of postoperative 24 and 48 h sore throat and hoarseness,RESULTSThe incidence of moderate-to-severe tracheal injury was 32/90 (35.6%) in the DLT group, and 45/92 (48.9%) in the VDLT group (P = 0.077; relative risk 1.38, 95% CI, 0.97 to 1.95). The incidence of vocal cord injury was 31/90 (34.4%) and 34/92 (37%) in the DLT and VDLT groups, respectively (P = 0.449). The incidence of postoperative 24 h sore throat and hoarseness was significantly higher in the VDLT group than in the DLT group (for sore throat: P = 0.032, relative risk 1.63, 95% CI, 1.03 to 2.57; for hoarseness: P = 0.018, relative risk 1.48, 95% CI, 1.06 to 2.06).CONCLUSIONThere was no statistically significant difference in the incidence of moderate-to-severe tracheal injury and vocal cord injury between DLTs and VDLTs. While improving the first-attempt success rate, intubation with VDLT increased the incidence of postoperative 24 h sore throat and hoarseness.TRIAL REGISTRATIONChinese Clinical Trial Registry identifier: ChiCTR2300067348.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 50 条
  • [1] Efficacy and safety of video double-lumen tube intubation in lateral position in patients undergoing thoracic surgery: a randomized controlled trial
    Rao, Qianqian
    Yu, Hong
    Li, Ping
    Zhang, Gongwei
    Zeng, Jun
    Pu, Qiang
    Yu, Hai
    BMC ANESTHESIOLOGY, 2024, 24 (01):
  • [2] Difficult intubation with double-lumen tubes
    Samaniego Gonzalez, C.
    Viroles Torrent, G.
    Sanchez Villalobos, J.
    Metje Ycra, M.
    Villalonga Morales, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 276 - 276
  • [3] FIBEROPTIC INTUBATION AND DOUBLE-LUMEN TUBES
    ROSS, DG
    ANAESTHESIA, 1990, 45 (10) : 895 - 895
  • [4] A randomized comparison between the VivaSight double-lumen tube and standard double-lumen tube intubation in thoracic surgery patients
    Palaczynski, Piotr
    Misiolek, Hanna
    Bialka, Szymon
    Owczarek, Aleksander J.
    Gola, Wojciech
    Szarpak, Lukasz
    Smereka, Jacek
    JOURNAL OF THORACIC DISEASE, 2022, : 3903 - 3914
  • [5] A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic
    Heir, Jagtar Singh
    Guo, Shu-Lin
    Purugganan, Ronaldo
    Jackson, Tim A.
    Sekhon, Anupamjeet Kaur
    Mirza, Kazim
    Lasala, Javier
    Feng, Lei
    Cata, Juan P.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 267 - 274
  • [6] A Retrospective Evaluation of the Use of Video-Capable Double-Lumen Endotracheal Tubes in Thoracic Surgery
    Heir, Jagtar Singh
    Purugganan, Ron
    Jackson, Timothy A.
    Norman, Peter H.
    Cata, Juan P.
    Kosturakis, Alyssa
    Thakar, Dilip
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) : 870 - 872
  • [7] Spontaneous ventilation combined with double-lumen tube intubation in thoracic surgery
    József Furák
    Zsolt Szabó
    General Thoracic and Cardiovascular Surgery, 2021, 69 : 976 - 982
  • [8] Spontaneous ventilation combined with double-lumen tube intubation in thoracic surgery
    Furak, Jozsef
    Szabo, Zsolt
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2021, 69 (06) : 976 - 982
  • [9] Effect of intubation in lateral position on placement of a double-lumen tube in patients undergoing unilateral video-assisted thoracic surgery: a randomied clinical trial
    Zhang, Xi
    Wang, Dongxu
    Zhang, Zhenduo
    Tang, Yawen
    Zhang, Qin
    Tong, Fei
    Hu, Yonghe
    Lu, Xian
    Liu, He
    Hu, Siping
    ECLINICALMEDICINE, 2024, 67
  • [10] ANESTHESIA FOR THORACIC-SURGERY .1. DOUBLE-LUMEN TUBE INTUBATION
    BENUMOF, JL
    ANESTHESIA AND THE LUNG, 1989, : 133 - 139