Detection of impending reflex syncope by means of an integrated multisensor patch-type recorder

被引:0
|
作者
Groppelli, Antonella [1 ,2 ]
Rafanelli, Martina [3 ,4 ]
Testa, Giuseppe Dario [3 ,4 ]
Agusto, Samuele [3 ,4 ]
Rivasi, Giulia [3 ,4 ]
Carbone, Erika [5 ]
Soranna, Davide [5 ]
Zambon, Antonella [5 ,6 ]
Castiglioni, Paolo [7 ,8 ]
Ungar, Andrea [3 ,4 ]
Brignole, Michele [1 ,2 ]
Parati, Gianfranco [1 ,2 ,9 ]
机构
[1] San Luca Hosp, IRCCS Ist Auxol Italiano, Cardiol Unit, Faint & Fall Programme, Milan, Italy
[2] San Luca Hosp, Dept Cardiol, Milan, Italy
[3] Univ Florence, Div Geriatr & Intens Care Med, Syncope Unit, Florence, Italy
[4] Azienda Osped Univ Careggi, Florence, Italy
[5] IRCCS Ist Auxol Italiano, Biostat Unit, Milan, Italy
[6] Univ Milano Bicocca, Dept Stat & Quantitat Methods, Milan, Italy
[7] IRCCS Fdn Don C Gnocchi ONLUS, Milan, Italy
[8] Univ Insubria, Dept Biotechnol & Life Sci DBSV, Varese, Italy
[9] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
关键词
HEART-RATE-VARIABILITY; POWER SPECTRAL-ANALYSIS; BLOOD-PRESSURE; TILT; FINGER;
D O I
10.1038/s41371-023-00840-y
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We assessed the capability of an integrated multisensory patch-type monitor (RootiRx (R)) in detecting episodes of reflex (pre)syncope induced by tilt table test (TTT). Firstly, we performed an intrapatient comparison of cuffless systolic blood pressure (SBP), R-R interval (RRI) and variability (power spectrum analysis) obtained by means of the RootiRx (R) with those obtained with conventional methods (CONV) with validated finger pressure devices at baseline in supine position and repeatedly during TTT in 32 patients affected by likely reflex syncope. Secondly, the LF/HF values obtained with RootiRx (R) during TTT were analyzed in 50 syncope patients. Compared with baseline supine recordings, during TTT a decrement of median SBP was observed with CONV (-53.5 mmHg) but not with RootiRx (R) (R)(-1 mmHg). Conversely, RRI reduction (CONV: 102 ms; RootiRx (R): 127 ms) and RRI Low Frequency/High Frequency powers ratio (LF/HF) increase (CONV: 1.6; RootiRx (R): 2.5) were similar. The concordance was good for RRI (0.97 [95% CI 0.96-0.98]) and fair for LF/HF ratio (0.69 [95% CI 0.46-0.83]). During the first 5 min of TTT the LF/HF ratio was higher in patients who later developed syncope than in no-syncope patients. This ratio was significantly different among patients with syncope, presyncope or without symptoms at the time of syncope (p value = 0.02). In conclusion, cuffless RootiRx (R) was unable to detect rapid drops of SBP occurring during impending reflex syncope and thus cannot be used as a diagnostic tool for hypotensive syncope. On the other hand, RRI mean values and LF/HF power ratios obtained with RootiRx (R) were consistent with those simultaneously obtained using conventional methods.
引用
收藏
页码:1098 / 1104
页数:7
相关论文
共 9 条
  • [1] Detection of impending reflex syncope by means of an integrated multisensor patch-type recorder
    Antonella Groppelli
    Martina Rafanelli
    Giuseppe Dario Testa
    Samuele Agusto
    Giulia Rivasi
    Erika Carbone
    Davide Soranna
    Antonella Zambon
    Paolo Castiglioni
    Andrea Ungar
    Michele Brignole
    Gianfranco Parati
    Journal of Human Hypertension, 2023, 37 : 1098 - 1104
  • [2] Automatic Real-Time Embedded QRS Complex Detection for a Novel Patch-Type Electrocardiogram Recorder
    Saadi, Dorthe B.
    Tanev, George
    Flintrup, Morten
    Osmanagic, Armin
    Egstrup, Kenneth
    Hoppe, Karsten
    Jennum, Poul
    Jeppesen, Jorgen L.
    Iversen, Helle K.
    Sorensen, Helge B. D.
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2015, 3
  • [3] Auto-detection of R wave in ECG (electrocardiography) for patch-type ECG remote monitoring system
    Kim M.S.
    Cho Y.C.
    Seo S.-T.
    Son C.-S.
    Kim Y.-N.
    Biomedical Engineering Letters, 2011, 1 (3) : 180 - 187
  • [4] Development of a Patch-Type Electrocardiographic Monitor for Real Time Heartbeat Detection and Heart Rate Variability Analysis
    Liu, Shing-Hong
    Wang, Jia-Jung
    Su, Chun-Hung
    Tan, Tan-Hsu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (03) : 411 - 423
  • [5] Development of a Patch-Type Electrocardiographic Monitor for Real Time Heartbeat Detection and Heart Rate Variability Analysis
    Shing-Hong Liu
    Jia-Jung Wang
    Chun-Hung Su
    Tan-Hsu Tan
    Journal of Medical and Biological Engineering, 2018, 38 : 411 - 423
  • [6] Simultaneous Measurement of Respiratory and Pulse Information Using a Patch-Type Sensor for Sleep Apnea Hypopnea Detection
    Ota, Yukino
    Yoshida, Tomoki
    Nagaoka, Hiroshi
    Takahashi, Masaki
    IEEE SENSORS LETTERS, 2023, 7 (10)
  • [7] Energy-Efficient Power Management Interface With Adaptive HV Multimode Stimulation for Power-Sensor Integrated Patch-Type Systems
    Kim, Myeong Woo
    Kim, Hyunjoong
    Song, Minseop
    Kim, Jae Joon
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2023, 17 (06) : 1355 - 1370
  • [8] Respiratory Event Detection During Sleep Using Electrocardiogram and Respiratory Related Signals: Using Polysomnogram and Patch-Type Wearable Device Data
    Yeo, Minsoo
    Byun, Hoonsuk
    Lee, Jiyeon
    Byun, Jungick
    Rhee, Hak Young
    Shin, Wonchul
    Yoon, Heenam
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (02) : 550 - 560
  • [9] Comparison Between the 24-hour Hotter Test and 72-hour Single-Lead Electrocardiogram Monitoring With an Adhesive Patch-Type Device for Atrial Fibrillation Detection: Prospective Cohort Study
    Kwon, Soonil
    Lee, So-Ryoung
    Choi, Eue-Keun
    Ahn, Hyo-Jeong
    Song, Hee-Seok
    Lee, Young-Shin
    Oh, Seil
    Lip, Gregory Y. H.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2022, 24 (05)