Solar air heater;
Heat transfer;
Exergy loss;
Exergy efficiency;
Thermal ef-ficiency;
FRICTION FACTOR CORRELATIONS;
TRANSFER ENHANCEMENT;
TRANSFER COEFFICIENT;
ARTIFICIAL ROUGHNESS;
RECTANGULAR DUCT;
TRANSVERSE RIBS;
ROUGHENED DUCT;
CHANNEL;
FLOW;
D O I:
10.24425/ather.2023.147546
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
Improvement in the exegetic efficiency of a solar air heater (SAH) can be done by enhancing the rate of heat transfer. In this work, the exergetic efficiency optimization of an artificially roughened solar air heater having an inverted L-shape rib has been performed. The numerical analysis of the exergetic performance of the solar air heater was carried out at a constant heat flux of 1000 W/m2. The study was conducted to investigate the effect of different relative roughness pitch (7.14-17.86) on the exergy losses, under the Reynolds number range of 3000 to 18 000. The roughness parameter of this geometry has been optimized and found to be among functional operating parameters like average solar intensity and temperature rise across the collector. The optimized value of relative roughness pitch is 17.86 at the isolation of 1000 W/m2, and the parameter of temperature rise ranges from 0.005 to 0.04.
机构:
Cent Bldg Res Inst, Architecture Planning & Energy Efficiency, Roorkee, India
Cent Bldg Res Inst, Architecture Planning & Energy Efficiency, Roorkee 247667, IndiaCent Bldg Res Inst, Architecture Planning & Energy Efficiency, Roorkee, India