Use of Resonant Acoustic Mixing Technology for Ultra-Low-Dose Blending in a Single-Step Mixing Process

被引:2
|
作者
Frey, Kyle A. [1 ]
Baker, Helen [1 ]
Purcell, Dale K. [2 ]
Lewis, Andrew L. [1 ]
Engers, David A. [1 ]
机构
[1] Pharmaceut Sci, Quotient Sci, 3080 McCann Farm Dr, Garnet Valley, PA 19060 USA
[2] Analyt Microscopy & Microanal, Chem Microscopy, W Lafayette, IN USA
关键词
acicular morphology; blend uniformity; caffeine; ultra-low dose; Resonant Acoustic Mixing (RAM); PARTICLE-SIZE; POWDER; CRITERIA;
D O I
10.1007/s11095-023-03629-3
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose To evaluate the use of resonant acoustic mixing (RAM) technology for homogenous blending of a morphologically challenging model API in low-dose concentrations (<0.1% w/w), and assess the potential for blend uniformity (BU) optimization.Methods Caffeine (CAF) mixing was carried out using a LabRAM I benchtop mixer. Uniformity was assessed under a range of mixing conditions and sample preparation procedures in order to optimize system performance. The capacity for microscale mixing was evaluated from final parameters for 0.05% and 0.0125% CAF blends.Results Upon optimization, RAM was able to accurately prepare homogeneous mixtures of <0.1% CAF in dilutions of up to 1 part per 8,000. Results from a 0.05% blend targeting 125 mu g CAF dosage amounts revealed an AV score of 8.8 while a 0.0125% w/w blend accurately prepared 25 mu g of CAF with 99.3% accuracy (98.7% label claim) and AV of 10.1. Microscale mixing in the 0.05% w/w blend was confirmed from plots of BU data against sample size demonstrating a slope of 0.05 within the range of 250-10 mg sample (125-5 mu g CAF). L1 BU criteria only failed at the level of 2 mu g CAF, despite target precision to 26 nanograms (98.7% label claim).Conclusions This study presents the first instance of a homogenously mixed <0.1% (w/w) blend using RAM technology and demonstrate the suitability for reproducible dosing of single-digit microgram drug amounts. Uniformity is documented for API amounts 60x smaller than a recent report has shown and 10,000x smaller than achieved previously with CAF.
引用
收藏
页码:165 / 183
页数:19
相关论文
共 9 条
  • [1] Use of Resonant Acoustic Mixing Technology for Ultra-Low-Dose Blending in a Single-Step Mixing Process
    Kyle A. Frey
    Helen Baker
    Dale K. Purcell
    Andrew L. Lewis
    David A. Engers
    Pharmaceutical Research, 2024, 41 : 165 - 183
  • [2] Assessment of Resonant Acoustic Mixing for Low-Dose Pharmaceutical Powder Blends
    Shashwat Gupta
    Yu Elaine Pu
    Minglu Li
    Zhengmao Li
    Juan G. Osorio
    AAPS PharmSciTech, 23
  • [3] Assessment of Resonant Acoustic Mixing for Low-Dose Pharmaceutical Powder Blends
    Gupta, Shashwat
    Pu, Yu Elaine
    Li, Minglu
    Li, Zhengmao
    Osorio, Juan G.
    AAPS PHARMSCITECH, 2022, 23 (05)
  • [4] Comparative study of the low-temperature single step mixing and multi-stage process mixing
    Wang, Chuansheng
    Song, Guozong
    Zhao, Shuhong
    Ren, Na
    Wang, Dong
    ADVANCED POLYMER PROCESSING III, 2013, 561 : 113 - 118
  • [5] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Ryoma Tanaka
    Naoyuki Takahashi
    Yasuaki Nakamura
    Yusuke Hattori
    Kazuhide Ashizawa
    Makoto Otsuka
    Analytical Sciences, 2017, 33 : 41 - 46
  • [6] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Tanaka, Ryoma
    Takahashi, Naoyuki
    Nakamura, Yasuaki
    Hattori, Yusuke
    Ashizawa, Kazuhide
    Otsuka, Makoto
    ANALYTICAL SCIENCES, 2017, 33 (01) : 41 - 46
  • [7] Ultra-fast fabrication of tape-cast anode supports for solid oxide fuel cells via resonant acoustic mixing technology
    Park, Jeong Hwa
    Bae, Kyung Taek
    Kim, Kyeong Joon
    Joh, Dong Woo
    Kim, Doyeub
    Myung, Jae-Ha
    Lee, Kang Taek
    CERAMICS INTERNATIONAL, 2019, 45 (09) : 12154 - 12161
  • [8] A low temperature single-step RTA process to form ultra-thin CoSi2 for MOSFET applications
    Sherony, MJ
    Sriram, TS
    England, C
    Pelillo, A
    Harris, WC
    Miller, SJ
    Bill, SA
    Yang, IY
    Wei, A
    Antoniadis, DA
    SILICIDE THIN FILMS - FABRICATION, PROPERTIES, AND APPLICATIONS, 1996, 402 : 209 - 214
  • [9] Mixing of low-dose cohesive drug and overcoming of pre-blending step using a new gentle-wing high-shear mixer granulator
    Alsulays, Bader B.
    Fayed, Mohamed H.
    Alalaiwe, Ahmed
    Alshahrani, Saad M.
    Alshetaili, Abdullah S.
    Alshehri, Sultan M.
    Alanazi, Fars K.
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2018, 44 (09) : 1520 - 1527