Discrimination of Diabetes Mellitus Patients and Healthy Individuals Based on Volatile Organic Compounds (VOCs): Analysis of Exhaled Breath and Urine Samples by Using E-Nose and VE-Tongue

被引:10
|
作者
Zaim, Omar [1 ,2 ]
Bouchikhi, Benachir [1 ]
Motia, Soukaina [1 ,2 ]
Abello, Sonia [3 ]
Llobet, Eduard [4 ]
El Bari, Nezha [2 ]
机构
[1] Moulay Ismail Univ Meknes, Fac Sci, Biosensors & Nanotechnol Grp, BP 11201 Zitoune, Meknes 50000, Morocco
[2] Moulay Ismail Univ Meknes, Fac Sci, Dept Biol, Biosensors & Nanotechnol Grp, BP 11201 Zitoune, Meknes 50000, Morocco
[3] Univ Rovira & Virgili, Sci & Tech Resources Serv, Mass Spectrometry Unit, Campus Sescelades,Edif N2,Avinguda Paisos Catalans, Tarragona 43007, Spain
[4] Univ Rovira & Virgili, Dept Elect Engn, MINOS, Avda Paisos Catalans 26, Tarragona 43007, Spain
关键词
type 1 diabetes mellitus; type 2 diabetes mellitus; breath analysis; urine analysis; electronic sensing system; data fusion; ION MOBILITY SPECTROMETRY; ELECTRONIC NOSE; LUNG-CANCER; MASS SPECTROMETRY; GC-MS; IDENTIFICATION; BIOMARKERS; DIAGNOSIS; DISEASE; TIME;
D O I
10.3390/chemosensors11060350
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Studies suggest that breath and urine analysis can be viable non-invasive methods for diabetes management, with the potential for disease diagnosis. In the present work, we employed two sensing strategies. The first strategy involved analyzing volatile organic compounds (VOCs) in biological matrices, such as exhaled breath and urine samples collected from patients with diabetes mellitus (DM) and healthy controls (HC). The second strategy focused on discriminating between two types of DM, related to type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM), by using a data fusion method. For this purpose, an electronic nose (e-nose) based on five tin oxide (SnO2) gas sensors was employed to characterize the overall composition of the collected breath samples. Furthermore, a voltametric electronic tongue (VE-tongue), composed of five working electrodes, was dedicated to the analysis of urinary VOCs using cyclic voltammetry as a measurement technique. To evaluate the diagnostic performance of the electronic sensing systems, algorithm tools including principal component analysis (PCA), discriminant function analysis (DFA) and receiver operating characteristics (ROC) were utilized. The results showed that the e-nose and VE-tongue could discriminate between breath and urine samples from patients with DM and HC with a success rate of 99.44% and 99.16%, respectively. However, discrimination between T1DM and T2DM samples using these systems alone was not perfect. Therefore, a data fusion method was proposed as a goal to overcome this shortcoming. The fusing of data from the two instruments resulted in an enhanced success rate of classification (i.e., 93.75% for the recognition of T1DM and T2DM).
引用
收藏
页数:20
相关论文
共 7 条
  • [1] Simultaneous assessment of volatile organic compound-based urinary and exhaled breath tests for diabetes diagnosis by using E-nose and VE-tongue systems
    Zaim, Omar
    Elyoubi, Hafsa
    El Bari, Nezha
    Bouchikhi, Benachir
    2022 IEEE INTERNATIONAL SYMPOSIUM ON OLFACTION AND ELECTRONIC NOSE (ISOEN 2022), 2022,
  • [2] Electronic nose (E-nose) analysis of exhaled volatile organic compounds (VOCs) distinguishes pediatric patients (pts) with Cystic fibrosis (CF) from healthy controls (HC) and depicts disease status
    Lucca, Francesca
    Volpi, Sonia
    Tenero, Laura
    Piazza, Michele
    Sandri, Marco
    Cipolli, Marco
    Piacentini, Giorgio
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [3] Comparative analysis of volatile organic compounds of breath and urine for distinguishing patients with liver cirrhosis from healthy controls by using electronic nose and voltammetric electronic tongue
    Zaim, Omar
    Diouf, Alassane
    El Bari, Nezha
    Lagdali, Naoual
    Benelbarhdadi, Imane
    Ajana, Fatima Zohra
    Llobet, Eduard
    Bouchikhi, Benachir
    ANALYTICA CHIMICA ACTA, 2021, 1184
  • [4] Variations in volatile organic compounds in Zhenyuan Daocai samples at different storage durations evaluated using E-nose, E-tongue, gas chromatography, and spectrometry
    Liu, Xueting
    Wang, Xueli
    Cheng, Yanwei
    Wu, Yuangen
    Yan, Yan
    Li, Zhen
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2023, 173
  • [5] Analysis of Volatile Organic Compounds in Milk during Heat Treatment Based on E-Nose, E-Tongue and HS-SPME-GC-MS
    Yuan, Ning
    Chi, Xuelu
    Ye, Qiaoyan
    Liu, Huimin
    Zheng, Nan
    FOODS, 2023, 12 (05)
  • [6] Comparative Analysis of Flavor, Taste, and Volatile Organic Compounds in Opossum Shrimp Paste during Long-Term Natural Fermentation Using E-Nose, E-Tongue, and HS-SPME-GC-MS
    Deng, Yijia
    Wang, Rundong
    Zhang, Yuhao
    Li, Xuepeng
    Gooneratne, Ravi
    Li, Jianrong
    FOODS, 2022, 11 (13)
  • [7] Discrimination and characterization of the volatile organic compounds in red and black raspberry wines fermented with different commercial Saccharomyces cerevisiae: An integrated analysis using E-nose, GC-MS, GC-IMS, and multivariate statistical models
    Wang, Yuanyuan
    Ma, Yinghu
    Duan, Jianling
    Wang, Bo
    Ma, Tengzhen
    Jiang, Yumei
    Zhang, Bo
    FOOD CHEMISTRY, 2025, 478