Intraoperative Three-Dimensional Transvaginal Ultrasound for Hysteroscopic Metroplasty: a Controlled Study

被引:2
|
作者
Muzii, Ludovico [1 ]
Galati, Giulia [1 ]
Mattei, Giulia [1 ]
Romito, Alessia [1 ]
Di Donato, Violante [1 ]
Palaia, Innocenza [1 ]
Bogani, Giorgio [2 ]
Angioli, Roberto [3 ]
机构
[1] Sapienza Univ Rome, Dept Maternal & Child Hlth & Urol Sci, Rome, Italy
[2] Fdn IRCCS Ist Nazl Tumori Milano, Milan, Italy
[3] Univ Rome, Dept Obstet & Gynaecol, Campus Biomed, Rome, Italy
关键词
Operative hysteroscopy; Recurrent pregnancy loss; Uterine septum; 3D ultrasound; SEPTATE UTERUS; SEPTUM RESECTION; UTERINE SEPTUM; ULTRASONOGRAPHY; CLASSIFICATION; WOMEN; MANAGEMENT; DIAGNOSIS; ANOMALIES; ACCURACY;
D O I
10.1007/s43032-023-01277-x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study aims to evaluate the role of intraoperative transvaginal three-dimensional ultrasound (3DUS) during hysteroscopic metroplasty. This is a prospective cohort of consecutive patients with septate uterus undergoing hysteroscopic metroplasty with intraoperative transvaginal 3DUS guidance compared to a historical control group of patients undergoing hysteroscopic metroplasty without 3DUS. We conducted our research in a tertiary care university hospital in Rome, Italy. This study involved nineteen patients undergoing 3DUS-guided hysteroscopic metroplasty for recurrent abortion or infertility compared to 19 age-matched controls undergoing metroplasty without 3DUS guidance. During hysteroscopic metroplasty, 3DUS was performed in the study group when the operator considered the procedure to be completed, according to standards of operative hysteroscopy. If 3DUS diagnosed a residual septum, the procedure was continued until a 3DUS diagnosis of a normal fundus was obtained. The patients were followed with a 3DUS performed 3 months after the procedure. The numbers of complete resections (residual septum absent), suboptimal resections (measurable residual septum of less than 10 mm), and incomplete resections (residual septum > 10 mm) in the intraoperative 3DUS group were compared to the numbers in the control group with no intraoperative 3DUS. At follow-up, measurable residual septa were obtained in 0% of the patients in the 3DUS-guided group versus 26% in the control group (p = 0.04). Residual septa of > 10 mm were obtained in 0% of the 3DUS group versus 10.5% in the control group (p = 0.48). Intraoperative 3DUS reduces the incidence of suboptimal septal resections at hysteroscopic metroplasty.
引用
收藏
页码:3372 / 3378
页数:7
相关论文
共 50 条
  • [1] Intraoperative Three-Dimensional Transvaginal Ultrasound for Hysteroscopic Metroplasty: a Controlled Study
    Ludovico Muzii
    Giulia Galati
    Giulia Mattei
    Alessia Romito
    Violante Di Donato
    Innocenza Palaia
    Giorgio Bogani
    Roberto Angioli
    Reproductive Sciences, 2023, 30 : 3372 - 3378
  • [2] Efficacy of Transrectal Three-Dimensional Ultrasound-Guided Hysteroscopic Metroplasty
    Kamel, Mostafa A. M.
    El-Tawab, Sally S.
    Enein, Loai Aboel
    El-Ashkar, Osama S.
    El-Meniawy, Nehal A.
    JOURNAL OF GYNECOLOGIC SURGERY, 2014, 30 (04) : 209 - 214
  • [3] Ultrasound guidance of hysteroscopic metroplasty, resection of intrauterine adhesions and hysteroscopic myomectomy: analysis of 1104 cases of intraoperative three-dimensional sonohysterography
    Guerrero, J.
    Rouleau, J. P.
    Vasquez, D.
    Vicario, R.
    Costa, M.
    Pirollo, L. M. A.
    Rodriguez-Fuentes, A.
    Palumbo, A.
    HUMAN REPRODUCTION, 2019, 34 : 26 - 26
  • [4] INTRAOPERATIVE THREE-DIMENSIONAL SONOHYSTEROGRAPHY: A NEW TECHNIQUE TO MONITOR HYSTEROSCOPIC METROPLASTY.
    Guerrero, J.
    Garcia, R.
    Hernandez, J.
    Iaconianni, L.
    Palumbo, A.
    FERTILITY AND STERILITY, 2010, 94 (04) : S77 - S78
  • [5] Three-dimensional transvaginal ultrasound in gynecological diagnosis
    Merz, E
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1999, 14 (02) : 81 - 86
  • [6] Three-dimensional transvaginal ultrasound in the diagnosis of adenomyosis.
    Bocchi, C
    Severi, FM
    Cobellis, L
    Ferretti, C
    Imperatore, A
    Luisi, S
    Petraglia, F
    JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2004, 11 (02) : 399A - 399A
  • [7] Value of three-dimensional transvaginal ultrasound in genital malformations
    LevToaff, AS
    Rawool, NM
    Segal, SR
    Goldberg, BB
    RADIOLOGY, 1997, 205 : 1504 - 1504
  • [8] Three-dimensional multiplanar transvaginal ultrasound of the cervix in pregnancy
    Bega, G
    Lev-Toaff, A
    Kuhlman, K
    Berghella, V
    Parker, L
    Goldberg, B
    Wapner, R
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (04) : 351 - 358
  • [9] Diagnosis of polycystic ovaries by three-dimensional transvaginal ultrasound
    Allemand, MC
    Tummon, IS
    Phy, JL
    Foong, SC
    Dumesic, DA
    Session, DR
    FERTILITY AND STERILITY, 2006, 85 (01) : 214 - 219
  • [10] Three-dimensional hysterosonographic evaluation of the normal endometrium: Comparison with transvaginal sonography and three-dimensional ultrasound
    BonillaMusoles, F
    Raga, F
    Blanes, J
    Osborne, NG
    Coelho, F
    JOURNAL OF GYNECOLOGIC SURGERY, 1997, 13 (03) : 101 - 107