Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy

被引:0
|
作者
Schoepe, Michael [1 ]
Sahlmann, Jacob [1 ]
Jaschik, Stefan [1 ]
Findeisen, Anne [1 ]
Klautke, Gunther [1 ]
机构
[1] Klinikum Chemnitz gGmbH, Dept Radiat Oncol, Burgerstr 2, D-09113 Chemnitz, Germany
关键词
Image guided radiotherapy; Stereotaxy; Positioning accuracy; Clinical patient positioning data; Monte Carlo simulation; RADIATION-THERAPY; RADIOSURGERY; SYSTEM; NECK; HEAD;
D O I
10.1007/s00066-023-02170-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThe objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X-ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS).MethodsPatient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X-ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X-ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile.ResultsThe interfractional measurement displacement vector of the SGRT system, sigma SGRT, in high resolution mode was estimated at 2.5 mm (68th percentile) and 5 mm (95th percentile). If the standard resolution was used, sigma SGRT increased by about 20%. The standard deviation of the axis-related sigma SGRT of the SGRT system ranged between 1.5 and 1.8 mm interfractionally and 0.5 and 1.0 mm intrafractionally. The magnitude of sigma SGRT is mainly due to the principle of patient surface scanning and not due to technical limitations or vendor-specific issues in software or hardware. Based on the resulting sigma SGRT, MC simulations served as a measure for the positioning accuracy for non-coplanar couch rotations. If an SGRT system is used as the only patient positioning device in non-coplanar fields, interfractional positioning errors of up to 6 mm and intrafractional errors of up to 5 mm cannot be ruled out. In contrast, MC simulations resulted in a positioning error of 1.6 mm (95th percentile) using the IGRT system. The cause of positioning errors in the SGRT system is mainly a change in the facial surface relative to a defined point in the brain.ConclusionIn order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X-ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 38 条
  • [1] Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy
    Michael Schöpe
    Jacob Sahlmann
    Stefan Jaschik
    Anne Findeisen
    Gunther Klautke
    Strahlentherapie und Onkologie, 2024, 200 : 60 - 70
  • [2] Reply to comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy
    Schoepe, M.
    Sahlmann, J.
    Jaschik, S.
    Findeisen, A.
    Klautke, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (07) : 644 - 645
  • [3] Letter to the Editor: reply to "Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy"
    Robinson, Adi
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (07) : 642 - 643
  • [4] Accuracy of surface-guided patient setup for conventional radiotherapy of brain and nasopharynx cancer
    Lee, Sang Kyu
    Huang, Sheng
    Zhang, Lei
    Ballangrud, Ase M.
    Aristophanous, Michalis
    Cervino Arriba, Laura I.
    Li, Guang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (05): : 48 - 57
  • [5] Dosimetric Comparison of Biologically-Guided Radiotherapy and X-ray-Guided Stereotactic Ablative Radiotherapy for Oligometastatic Prostate Cancer
    Hrinivich, W. T.
    Phillips, R.
    Da Silva, A.
    Radwan, N.
    Gorin, M.
    Rowe, S.
    Pienta, K.
    Pomper, M. G.
    Wong, J. W.
    Tran, P. T.
    Wang, K. K. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (05): : 1190 - 1190
  • [6] COMPARISON BETWEEN INFRARED OPTICAL AND STEREOSCOPIC X-RAY TECHNOLOGIES FOR PATIENT SETUP IN IMAGE GUIDED STEREOTACTIC RADIOTHERAPY
    Tagaste, Barbara
    Riboldi, Marco
    Spadea, Maria F.
    Bellante, Simone
    Baroni, Guido
    Cambria, Raffaella
    Garibaldi, Cristina
    Ciocca, Mario
    Catalano, Gianpiero
    Alterio, Daniela
    Orecchia, Roberto
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1706 - 1714
  • [7] Accuracy of patient setup positioning using surface-guided radiotherapy with deformable registration in cases of surface deformation
    Kadman, Boriphat
    Takemura, Akihiro
    Ito, Tatsuya
    Okada, Naoki
    Kojima, Hironori
    Ueda, Shinichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [8] Comparison of Intrafractional Motion with Two Immobilization Techniques in Surface-Guided Intracranial Stereotactic Radiosurgery
    Han, C.
    Amini, A.
    Liu, A.
    Wong, J. Y. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E750 - E750
  • [9] Comparison of intrafractional motion with two frameless immobilization systems in surface-guided intracranial stereotactic radiosurgery
    Han, Chunhui
    Amini, Arya
    Wong, Jeffrey Y. C.
    Liang, Jieming
    Qing, Kun
    Watkins, W. Tyler
    Zhang, Sean
    Williams, Terence M.
    Liu, An
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):
  • [10] Evaluation of patient setup uncertainty of optical guided frameless system for intracranial stereotactic radiosurgery
    Wang, Jia-Zhu
    Rice, Roger
    Pawlicki, Todd
    Mundt, Arno J.
    Sandhu, Ajay
    Lawson, Joshua
    Murphy, Kevin T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 92 - 100