Impact of continuous-flow mechanical circulatory support on cerebrospinal fluid motility

被引:0
|
作者
Rose, William [1 ]
Throckmorton, Amy L. [2 ,4 ]
Heintzelman, Briana [2 ]
Tchantchaleishvili, Vakhtang [3 ]
机构
[1] Univ Delaware, Dept Kinesiol & Appl Physiol, Newark, DE USA
[2] Drexel Univ, Sch Biomed Engn & Hlth Syst, BioCirc Res Lab, Philadelphia, PA USA
[3] Thomas Jefferson Univ Hosp, Dept Surg, Div Cardiac Surg, Philadelphia, PA USA
[4] Drexel Univ, Sch Biomed Engn & Sci Hlth Syst, BioCirc Res Lab, 3141 Chestnut St, Rm 718, Philadelphia, PA 19104 USA
关键词
blood pump; cerebral hemodynamics; cerebrospinal fluid; cerebrospinal fluid motility; mechanical circulatory support; ventricular assist device; ROTARY BLOOD PUMPS; MODEL; HYDRODYNAMICS; PRESSURE;
D O I
10.1111/aor.14624
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Mechanical circulatory support (MCS), including ventricular assist devices (VADs), have emerged as promising therapeutic alternatives for end-stage congestive heart failure (CHF). The latest generation of these devices are continuous flow (CF) blood pumps. While there have been demonstrated benefits to patient outcomes due to CF-MCS, there continue to be significant clinical challenges. Research to-date has concentrated on mitigating thromboembolic risk (stroke), while the downstream impact of CF-MCS on the cerebrospinal fluid (CSF) flow has not been well investigated. Disturbances in the CSF pressure and flow patterns are known to be associated with neurologic impairment and diseased states. Thus, here we seek to develop an understanding of the pathophysiologic consequences of CF-MCS on CSF dynamics.Methods: We built and validated a computational framework using lumped parameter modeling of cardiovascular, cerebrovascular physics, CSF dynamics, and autoregulation. A sensitivity analysis was performed to confirm robustness of the modeling framework. Then, we characterized the impact of CF-MCS on the CSF and investigated cardiovascular conditions of healthy and end-stage heart failure.Results: Modeling results demonstrated appropriate hemodynamics and indicated that CSF pressure depends on blood flow pulsatility more than CSF flow. An acute equilibrium between CSF production and absorption was observed in the CF-MCS case, characterized by CSF pressure remaining elevated, and CSF flow rates remaining below healthy, but higher than CHF states.Conclusion: This research has advanced our understanding of the impact of CF-MCS on CSF dynamics and cerebral hemodynamics.
引用
收藏
页码:1567 / 1580
页数:14
相关论文
共 50 条
  • [1] Complications of Continuous-Flow Mechanical Circulatory Support Devices
    Patel, Harsh
    Madanieh, Raef
    Kosmas, Constantine E.
    Vatti, Satya K.
    Vittorio, Timothy J.
    CLINICAL MEDICINE INSIGHTS-CARDIOLOGY, 2015, 9 : 15 - 21
  • [2] FEATURES OF LONG-TERM MECHANICAL CIRCULATORY SUPPORT WITH CONTINUOUS-FLOW PUMP
    Itkin, G. P.
    Shokhina, E. G.
    Shemakin, S. Y.
    Poptsov, V. N.
    Shumakov, D. V.
    Gautier, S. V.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2012, 14 (02): : 110 - 115
  • [3] Effect of Continuous-Flow Mechanical Circulatory Support on Microvasculature Remodeling in the Failing Heart
    Saito, Tetsuya
    Miyagawa, Shigeru
    Toda, Koichi
    Yoshikawa, Yasushi
    Fukushima, Satsuki
    Saito, Shunsuke
    Yoshioka, Daisuke
    Sakata, Yasushi
    Daimon, Takashi
    Sawa, Yoshiki
    ARTIFICIAL ORGANS, 2019, 43 (04) : 350 - 362
  • [4] Contemporary Mechanical Circulatory Support With Continuous-Flow Biventricular Assist Devices: A Systematic Review
    Meece, Lauren E.
    Yu, Julia
    Jeng, Eric, I
    Ahmed, Mustafa M.
    CARDIOLOGY IN REVIEW, 2022, 30 (04) : 197 - 205
  • [5] Mechanical Circulatory Support for the Failing Heart: Continuous-Flow Left Ventricular Assist Devices
    Englert, Joseph A. R., III
    Davis, Jennifer A.
    Krim, Selim R.
    OCHSNER JOURNAL, 2016, 16 (03): : 263 - 269
  • [6] Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
    Pagani, Francis D.
    Miller, Leslie W.
    Russell, Stuart D.
    Aaronson, Keith D.
    John, Ranjit
    Boyle, Andrew J.
    Conte, John V.
    Bogaev, Roberta C.
    MacGillivray, Thomas E.
    Naka, Yoshifumi
    Mancini, Donna
    Massey, H. Todd
    Chen, Leway
    Klodell, Charles T.
    Aranda, Juan M.
    Moazami, Nader
    Ewald, Gregory A.
    Farrar, David J.
    Frazier, O. Howard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) : 312 - 321
  • [7] Mechanical Circulatory Support for Biventricular Heart Failure Using Continuous-Flow Total Artificial Heart
    Karimov, J. H.
    Horvath, D.
    Byram, N.
    Polakowski, A.
    Adams, J.
    Kado, Y.
    Miyamoto, T.
    Sale, S.
    Kuban, B.
    Fukamachi, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S343 - S343
  • [8] Optimism derived from 7.5 years of continuous-flow circulatory support
    Westaby, Stephen
    Banning, Adrian
    Neil, Desley
    Poole-Wilson, Philip
    Frazier, O. Howard
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (03): : E45 - E47
  • [9] Determining Brain Death After Therapeutic Hypothermia on Nonpulsatile Continuous-Flow Mechanical Circulatory Support Devices
    Rady, Mohamed Y.
    Verheijde, Joseph L.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (02) : E8 - +
  • [10] Continuous-flow biventricular mechanical support implantation strategies
    Eulert-Grehn, Jaime-Juergen
    Lanmueller, Pia
    Starck, Christoph
    Hennig, Felix
    Jacobs, Stephan
    Falk, Volkmar
    Potapov, Evgenij
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (03) : 408 - 410