A Comparative Study to Assess Accuracy of Casts Prepared using Direct Impression Technique with and without Splinting of Multiple Dental Implants Utilising Two Different Splinting and Impression Materials

被引:1
|
作者
Karia, Milap [1 ]
Vaghela, Ishita [1 ]
Ajmera, Hardik [2 ]
Detroja, Kishan [3 ]
Vasant, Jill D. [4 ]
Sharma, Devanshi [5 ]
Kumar, Amit [6 ]
Badiyani, Bhumika Kamal
机构
[1] Govt Dent Coll & Hosp, Dept Prosthodont & Crown & Bridge, Jamnagar, Gujarat, India
[2] Govt Dent Coll & Hosp, Dept Orthodont, Jamnagar, Gujarat, India
[3] Coll Dent Sci & Hosp, Dept Prosthodont & Crown & Bridge, Bhavnagar, Gujarat, India
[4] Clin Practitioner, Mumbai, Maharashtra, India
[5] Clin Practitioner, Dept Prosthodont & Crown & Bridge, Valsad, Gujrat, India
[6] Clin Practitioner, Dept Publ Hlth Dent, Mumbai, Maharashtra, India
关键词
Dental implants; direct impression processes; impression materials; splinting materials;
D O I
10.4103/jpbs.jpbs_271_23
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: The current study examined the accuracy of casts generated using direct impression processes with and without splints for multiple dental implants utilizing two different splinting materials and impression materials. Materials and Methods: Dental replacement base intensity alleviating acrylic tar was used to create a reference model of a mandible with four inserts (Uniti, Equinox, D-3.7 mm, and L-13 mm) in the front. Polyether and polyvinyle siloxane impression materials were used to make impressions of the reference model utilizing direct non-splinted and splinted techniques. Results: Polyether impression material was found to produce more accurate impressions than polyvinyl siloxane, and impressions made using transfer copings splinted with pattern resins were found to be more accurate than those made using either unsplinted copings or copings splinted with light-cured wax resin. Conclusions: All six impression techniques resulted in casts that were different from the reference model. Next, the polyether-splinted (SPR) technique is the nonsplinted technique employing polyether and polyvinyle siloxane imprint materials, and then, the splinted techniques using polyether and polyvinyle siloxane and produced the most accurate casts in comparison with the reference model.
引用
收藏
页码:S944 / S947
页数:4
相关论文
共 16 条
  • [1] Comparative evaluation of open tray impression technique: investigating the precision of four splinting materials in multiple implants
    Patil, Priyanka
    Madhav, V. N. V.
    Alshadidi, Abdulkhaliq Ali F.
    Saini, Ravinder S.
    Aldosari, Lujain Ibrahim N.
    Heboyan, Artak
    Mosaddad, Seyed Ali
    Hassan, Saeed Awod Bin
    Chaturvedi, Saurabh
    BMC ORAL HEALTH, 2023, 23 (01)
  • [2] Comparative evaluation of open tray impression technique: investigating the precision of four splinting materials in multiple implants
    Priyanka Patil
    V. N.V Madhav
    Abdulkhaliq Ali F. Alshadidi
    Ravinder S. Saini
    Lujain Ibrahim N. Aldosari
    Artak Heboyan
    Seyed Ali Mosaddad
    Saeed Awod Bin Hassan
    Saurabh Chaturvedi
    BMC Oral Health, 23
  • [3] Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials
    Tandon, Arpita
    Bulbule, Nilesh S.
    Jagtap, Amit K.
    Kakade, Dilip M.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (11) : ZC34 - ZC38
  • [4] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [5] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [6] A comparative analysis of the accuracy of different direct impression techniques for multiple implants
    Ongul, D.
    Gokcen-Rohlig, B.
    Sermet, B.
    Keskin, H.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 (02) : 184 - 189
  • [7] Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner
    Rcch-Ortega, Cristina
    Fernandez-Estevan, Lucia
    Fernanda Sola-Ruiz, Ma
    Agustin-Panadero, Ruben
    Labaig-Rueda, Carlos
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (01): : E89 - E95
  • [8] Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study
    Joseph, Thara Maria
    Ravichandran, R.
    Lylajam, S.
    Viswabharan, Prasanth
    Janardhanan, Kavitha
    Rajeev, Smitha
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (03): : 239 - 247
  • [9] Evaluation of Accuracy of Complete-Arch Multiple-Unit Abutment-Level Dental Implant Impressions Using Different Impression and Splinting Materials
    Buzayan, Muaiyed
    Baig, Mirza Rustum
    Yunus, Norsiah
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1512 - 1520
  • [10] Effect of core materials on the dimensional accuracy of casts made of two different silicone impression materials: An experimental study
    Farzin, Mitra
    Derafshi, Reza
    Giti, Rashin
    Kalantari, Mohammad-Hassan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (02): : 196 - 204