Split-flow layouts of supercritical CO2 Brayton cycle for coal-fired power plant considering the flue gas residual heat utilization

被引:0
|
作者
Wang, Limin [1 ]
Wang, Chang'an [1 ]
Bai, Wengang [2 ]
Jin, Liyan [1 ]
Yang, Xiaohu [3 ]
Che, Defu [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
[2] Xian Thermal Power Res Inst Co Ltd, Xian, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
coal-fired power plant; residual heat utilization; S-CO2 Brayton cycle; split-flow layouts; STRATEGIES; DESIGN;
D O I
10.1002/apj.2874
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The utilization of residual energy of high-temperature flue gas at the tail of coal-fired boilers has attracted widespread attention in recent years. The thermal performances of the boiler and system in different split-flow layouts still need to be analyzed and compared in detail. Thermodynamic models for four different splitting layouts of supercritical carbon dioxide (S-CO2) Brayton cycles tailored for coal-fired power plant are built and validated. By performing the process simulations, the effects of splitting ratios on the system thermal performance are comparatively analyzed when the secondary split point and the confluence point are set at different positions. The maximum system efficiency of the two-split layout with a secondary splitting point at the inlet of the cold side of the high-temperature recuperator (HTR) can be obtained within a range of secondary split ratio. The maximal and minimal boundaries are determined by the exhaust flue gas temperature and the heat capacity match in the recuperators, respectively. The mass flow rate of the cold stream in the low-temperature recuperator (LTR) should be kept unchanged by constraining the sum of primary and secondary split ratios, the constant to prevent the cycle efficiency from decreasing dramatically, if the splitting layout with the split point at the outlet of the main compressor (MC) is used. The two-splitting layout with a secondary splitting point at the inlet of the cold side of the HTR has the best performance by comparing the system efficiencies of different layouts. If there are any improved coupling approaches of the S-CO2 Brayton cycle and boiler, this paper can provide the reference for the selections of the split ratios.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Improved design of supercritical CO2 Brayton cycle for coal-fired power plant
    Zhang, Yifan
    Li, Hongzhi
    Han, Wanlong
    Bai, Wengang
    Yang, Yu
    Yao, Mingyu
    Wang, Yueming
    ENERGY, 2018, 155 : 1 - 14
  • [2] Supercritical CO2 Brayton cycles for coal-fired power plants
    Mecheri, Mounir
    Le Moullec, Yann
    ENERGY, 2016, 103 : 758 - 771
  • [3] Thermodynamic and economic investigation of coal-fired power plant combined with various supercritical CO2 Brayton power cycle
    Park, SungHo
    Kim, JoonYoung
    Yoon, MunKyu
    Rhim, DongRyul
    Yeom, ChoongSub
    APPLIED THERMAL ENGINEERING, 2018, 130 : 611 - 623
  • [4] Study on a Coal-Fired Power Plant with CO2 Flue Gas Scrubbing
    Heischkamp, Elizabeth
    Oeljeklaus, Gerd
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 1019 - 1025
  • [5] A supercritical CO2 Brayton cycle with a bleeding anabranch used in coal-fired power plants
    Bai, Ziwei
    Zhang, Guoqiang
    Li, Yongyi
    Xu, Gang
    Yang, Yongping
    ENERGY, 2018, 142 : 731 - 738
  • [6] Conceptual study of a high efficiency coal-fired power plant with CO2 capture using a supercritical CO2 Brayton cycle
    Le Moullec, Yann
    ENERGY, 2013, 49 : 32 - 46
  • [7] Exergy analysis of a 1000 MW single reheat supercritical CO2 Brayton cycle coal-fired power plant
    Zhou, Jing
    Zhang, Chenhao
    Su, Sheng
    Wang, Yi
    Hu, Song
    Liu, Liang
    Ling, Peng
    Zhong, Wenqi
    Xiang, Jun
    ENERGY CONVERSION AND MANAGEMENT, 2018, 173 : 348 - 358
  • [8] Corrosion in CO2 capture unit for coal-fired power plant flue gas
    Veawab, A
    GREENHOUSE GAS CONTROL TECHNOLOGIES, VOLS I AND II, PROCEEDINGS, 2003, : 1595 - 1598
  • [9] Calcium looping with supercritical CO2 cycle for decarbonisation of coal-fired power plant
    Hanak, Dawid P.
    Manovic, Vasilije
    ENERGY, 2016, 102 : 343 - 353
  • [10] CO2 fixation from the flue gas on coal-fired thermal power plant by microalgae
    EPDC Environmental Engineering, Service Co, Ltd
    Energy Convers Manage, 6-9 (717-720):