Recanalization of Xen45 gel stent implant occlusion using 10-0 nylon suture in refractory glaucoma: a case report

被引:1
|
作者
Zhang, Yao [1 ]
Xiang, Haotian [1 ]
Zhang, Yangyang [1 ]
Tang, Li [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Ophthalmol, Chengdu, Peoples R China
关键词
Glaucoma; Micro-invasive glaucoma surgery; Occlusion; Postoperative complications; Recanalization; Xen gel stent; OUTCOMES;
D O I
10.1186/s12886-023-03109-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundXen Gel Stent implant is a new minimally invasive surgical treatment for glaucoma that has been proven effectiveness and safety profile. However, it may also lead to some complications. Xen Gel Stent occlusion is a relatively rare complication reported less frequently and has limited treatment experience. In our case report, we proposed a novel surgical treatment using a 10 - 0 nylon suture to successfully recanalize the occluded Xen45 Gel Stent.Case presentationA 16-year-old female patient had bilateral juvenile glaucoma for the past 5 years. Her right eye had undergone three glaucoma surgeries but failed. At a presentation to our hospital, the right eye's intraocular pressure (IOP) was 30 mmHg despite applying four different active principles. Xen45 Gel Stent implant was chosen for treatment, but six days after implantation, the IOP rose to 40 mmHg as a result of an anterior chamber tip occlusion of the Xen45 Gel Stent. Nd: YAG laser shockwave therapy was attempted but failed. The patient eventually had to return to the operating room for a revision procedure. The Xen45 Gel Stent was recanalized from the ab externo by making an L-shaped conjunctival incision at the fornix base and threading a 10 - 0 nylon suture through it. The IOP was successfully controlled in the 11-month follow-up without medication.ConclusionIf postoperative occlusion arises after Xen45 Gel Stent implantation, surgery using 10 - 0 nylon suture to recanalize Xen45 Gel Stent should be considered as a relatively safe, effective that does not require removal of Xen45 Gel Stent.
引用
收藏
页数:6
相关论文
共 12 条
  • [1] Recanalization of Xen45 gel stent implant occlusion using 10 − 0 nylon suture in refractory glaucoma: a case report
    Yao Zhang
    Haotian Xiang
    Yangyang Zhang
    Li Tang
    BMC Ophthalmology, 23
  • [2] Xen45 gel stent ab interno trimming for ostium occlusion: case report
    Tatti, Filippo
    Gentile, Pietro
    Mangoni, Lorenzo
    Demarinis, Giuseppe
    Napoli, Pietro
    Fossarello, Maurizio
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [3] Xen45 gel stent ab interno trimming for ostium occlusion: case report
    Filippo Tatti
    Pietro Gentile
    Lorenzo Mangoni
    Giuseppe Demarinis
    Pietro Napoli
    Maurizio Fossarello
    BMC Ophthalmology, 21
  • [4] XEN® 63 gel stent to treat a refractory uveitic glaucoma: A case report
    Serrar, Yasmine
    Rezkallah, Amina
    Kodjikian, Laurent
    Poli, Muriel
    Mathis, Thibaud
    Denis, Philippe
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : NP32 - NP36
  • [5] Recanalization of XEN-45 gel stent occlusion with cortical material after phaco-XEN surgery using Nd: YAG laser treatment A case report
    Seo, Je Hyun
    Lim, Su-Ho
    MEDICINE, 2021, 100 (34) : E27010
  • [6] Safety and efficacy outcomes of the Xen45 Gel Stent use for refractory glaucoma: a surgery series from surgeon trainees at a tertiary teaching hospital
    Hong, Karen
    Lind, John
    Sheybani, Arsham
    EYE AND VISION, 2020, 7 (01)
  • [7] Safety and efficacy outcomes of the Xen45 Gel Stent use for refractory glaucoma: a surgery series from surgeon trainees at a tertiary teaching hospital
    Karen Hong
    John Lind
    Arsham Sheybani
    Eye and Vision, 7
  • [8] The Use of Fixation Suture to Treat Inferonasal Hypertrophic Bleb after Xen Gel Stent Implant: A Case Report
    Pavicic-Astalos, Jasna
    Ankamah, Emmanuel
    Nolan, John M.
    Ng, Eugene
    Garcia-Feijoo, Julian
    CASE REPORTS IN OPHTHALMOLOGY, 2022, 13 (01): : 253 - 258
  • [9] Inferior implant of XEN63 Gel stent in a refractory open-angle glaucoma due to silicone oil tamponade: A case report
    Savastano, Alfonso
    Carla, Matteo Mario
    Gambini, Gloria
    Giannuzzi, Federico
    Boselli, Francesco
    Rizzo, Stanislao
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (01) : NP27 - NP31
  • [10] Results of XEN45 Gel Stent Implantation in the Treatment of Primary Open-Angle Glaucoma Using 5, 10 or 20 μg Mitomycin C: A Pilot Study
    Reichel, Felix F.
    Guggenberger, Vanessa
    Faber, Hanna
    Neubauer, Jonas
    Voykov, Bogomil
    JOURNAL OF OPHTHALMOLOGY, 2024, 2024