Emission inventory of air pollutants from residential coal combustion over the Beijing-Tianjin-Hebei Region in 2020

被引:0
|
作者
Zhang, Ruting [1 ]
Chen, Chuanmin [1 ]
Liu, Songtao [1 ]
Wu, Huacheng [2 ]
Zhou, Weiqing [2 ]
Li, Peng [2 ]
机构
[1] North China Elect Power Univ, Dept Environm Sci & Engn, Hebei Key Lab Power Plant Flue Gas Multipollutants, 619 Yongbei Rd, Baoding 071003, Hebei, Peoples R China
[2] North China Elect Power Res Inst Co Ltd, State Grid Jibei Elect Power Co Ltd, Jibei Elect Power Res Inst, Beijing 100045, Peoples R China
来源
AIR QUALITY ATMOSPHERE AND HEALTH | 2023年 / 16卷 / 09期
关键词
Residential coal combustion; Air pollutants; Emission inventory; High resolution; Temporal and spatial distribution; Beijing-Tianjin-Hebei region; ENERGY-CONSUMPTION; ATMOSPHERIC POLLUTANTS; NORTHERN CHINA; RESOLUTION; PM2.5; REDUCTION; STOVES; TRANSITION; HOUSEHOLDS; POLLUTION;
D O I
10.1007/s11869-023-01375-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To investigate the atmospheric pollutant emission from residential coal combustion (RCC) in BTH region in 2020, based on the bottom-up methodology, a high spatial and temporal resolution air pollutant emission inventory was established. The results showed that the emissions of PM10, PM2.5, BC, OC, CO, NOx, SO2, and VOCs in BTH region in 2020 were 19.58, 15.67, 2.98, 8.33, 296.96, 3.51, 36.67, and 5.87 million tons, respectively. Chengde contributed the most PM2.5, BC, OC, and VOCs in BTH region, accounted for 11.48%, 13.71%, 11.52%, and 12.72%, respectively. While Shijiazhuang contributed the most PM10, CO, NOx, and SO2 in BTH region, accounted for 11.55%, 11.60%, 11.55%, and 12.10%, respectively. The spatial distribution characteristics of pollutants showed that high emissions concentrated in northern, eastern, and southern areas of BTH region. Based on the time distribution factor obtained from the long-term follow-up survey data of RCC of households in BTH region, the annual emissions of different cities were allocated according to the temporal resolution of monthly, daily, and hourly. It was found that for each pollutant, the highest emissions appeared in January; the higher emissions occurred in mid-December, early January, and mid-February; and the peak emission appeared at 8:00, 11:00, 18:00, and 21:00. Furthermore, the uncertainty analysis of the emission inventory was carried out by using the Monte Carlo method. This study provides a more high temporal and spatial resolution emission inventory of RCC for air quality model, which can accurately simulate regional pollutant emission scenarios.
引用
收藏
页码:1823 / 1832
页数:10
相关论文
共 50 条
  • [1] Emission inventory of air pollutants from residential coal combustion over the Beijing-Tianjin-Hebei Region in 2020
    Ruting Zhang
    Chuanmin Chen
    Songtao Liu
    Huacheng Wu
    Weiqing Zhou
    Peng Li
    Air Quality, Atmosphere & Health, 2023, 16 : 1823 - 1832
  • [2] Emission Inventory of Air Pollutants from Residential Coal Combustion Over the Beijing-Tianjin-Hebei Region in 2020
    Zhang, Ruting
    Chen, Chuanmin
    Liu, Songtao
    Wu, Huacheng
    Zhou, Weiqing
    Li, Peng
    Jia, Wenbo
    Cao, Yue
    SSRN, 2022,
  • [3] Emission inventory of air pollutants from coal combustion in Beijing-Tianjin-Hebei region
    Wu, Hua-Cheng
    Zhang, Ru-Ting
    Chen, Chuan-Min
    Zhou, Wei-Qing
    Li, Peng
    Zhongguo Huanjing Kexue/China Environmental Science, 2022, 42 (10): : 4547 - 4555
  • [4] Sophisticated emission inventory of air pollutants from coal-fired boilers in Beijing-Tianjin-Hebei region
    Liu, Jie-Yu
    Gao, Jia-Jia
    Tong, Ya-Li
    Yue, Tao
    Wang, Kun
    Wang, Xin
    Zhongguo Huanjing Kexue/China Environmental Science, 2022, 42 (05): : 2041 - 2049
  • [5] Study on the Inventory of Air Pollutants in Ports of Beijing-Tianjin-Hebei Region
    Zhang, Fan
    2019 INTERNATIONAL CONFERENCE ON ADVANCES IN CIVIL ENGINEERING, ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2019, 330
  • [6] Emission inventory of atmospheric pollutants replaced by coal-to-electricity policy in Beijing-Tianjin-Hebei region
    Li, Peng
    Wu, Hua-Cheng
    Zhou, Wei-Qing
    Zhang, Zi-Jian
    Wang, Mei-Shun
    Zhang, Ru-Ting
    Liu, Song-Tao
    Chen, Chuan-Min
    Zhongguo Huanjing Kexue/China Environmental Science, 2021, 41 (04): : 1489 - 1497
  • [7] A high-resolution air pollutants emission inventory in 2013 for the Beijing-Tianjin-Hebei region, China
    Qi, Ji
    Zheng, Bo
    Li, Meng
    Yu, Fang
    Chen, Chuchu
    Liu, Fei
    Zhou, Xiafei
    Yuan, Jing
    Zhang, Qiang
    He, Kebin
    ATMOSPHERIC ENVIRONMENT, 2017, 170 : 156 - 168
  • [8] Contributions of residential coal combustion to the air quality in Beijing-Tianjin-Hebei (BTH), China: a case study
    Li, Xia
    Wu, Jiarui
    Elser, Miriam
    Feng, Tian
    Cao, Junji
    El-Haddad, Imad
    Huang, Rujin
    Tie, Xuexi
    Prevot, Andre S. H.
    Li, Guohui
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2018, 18 (14) : 10675 - 10691
  • [9] Assessment of the effect of the reduction of the residential coal combustion on the atmospheric BaP pollution in Beijing-Tianjin-Hebei region
    京津冀民用燃煤减排对大气中BaP污染影响评估
    Meng, Fan (mengfan@craes.org.cn), 2018, Chinese Society for Environmental Sciences (38):
  • [10] Influence of air pollutants transport from key coal and electricity production bases on Beijing-Tianjin-Hebei region
    Bo, Xin
    Tian, Fei
    Tang, Wei
    Li, Yang
    Du, Xiao-Hui
    Lei, Xun-Jie
    Li, Shi-Bei
    Zhao, Xiao-Hong
    Sun, Hong-Tao
    Zhou, Bei-Hai
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (02): : 514 - 522