Rapid Analysis of Estrogens in Meat Samples by High Performance Liquid Chromatography with Fluorescence Detection

被引:3
|
作者
Yu, Shuiqiang [1 ]
You, Jinmao [1 ,2 ]
Shi, Xinxin [1 ]
Zou, Xiaocong [1 ]
Lu, Zhihao [1 ]
Wang, Yu [1 ]
Tan, Jiangkun [1 ]
Sun, Zhiwei [1 ]
Li, Zan [1 ]
Ji, Zhongyin [1 ]
Song, Cuihua [1 ]
机构
[1] Qufu Normal Univ, Sch Chem & Chem Engn, Key Lab Life Organ Anal Shandong Prov, Qufu 273165, Peoples R China
[2] Shaoxing Univ, Coll Chem & Chem Engn, Shaoxing 312000, Peoples R China
基金
中国国家自然科学基金;
关键词
Estrogens; Derivatization reagent; HPLC-FLD; 4-(N-Methyl-1; 3-dioxo-benzoisoquinolin-6-yl-oxy)benzene sulfonyl Chloride (MBIOBS-Cl); SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; BISPHENOL-A; STEROID-HORMONES; WATER SAMPLES; HUMAN PLASMA; METABOLITES; SERUM; QUANTIFICATION; DERIVATIZATION;
D O I
10.1007/s10895-023-03248-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel reagent named 4-(N-methyl-1,3-dioxo-benzoisoquinolin-6-yl-oxy)benzene sulfonyl chloride (MBIOBS-Cl) for the determination of estrogens in food samples by high-performance liquid chromatography (HPLC) with fluorescence detection has been developed. Estrogens could be easily labeled by MBIOBS-Cl in Na2CO3-NaHCO3 buffer solution at pH 10.0. The complete labeling reaction for estrogens could be accomplished within five minutes, the corresponding derivatives exhibited strong fluorescence with the maximum excitation and emission wavelengths at 249 nm and 443 nm, respectively. The derivatization conditions, such as the molar ratio of reagent to estrogens, derivatization time, pH, temperature, and buffers were optimized. Derivatives were sufficiently stable to be efficiently analyzed by HPLC with a reversed-phase Agilent ZORBAX 300SB-C18 column with a good baseline resolution. Excellent linear correlations were obtained for all estrogen derivatives with correlation coefficients greater than 0.9998. Ultrasonic-Assisted extraction was used to optimize the extraction of estrogens from meat samples with a recovery higher than 82%. The detection limits (LOD, S/N = 3) of the method ranged from 0.95 to 3.3 mu g center dot kg(-1). The established method, which is fast, simple, inexpensive, and environment friendly, can be successfully applied for the detection of four steroidal estrogens from meat samples with little matrix interference.
引用
收藏
页码:425 / 436
页数:12
相关论文
共 50 条
  • [1] Rapid Analysis of Estrogens in Meat Samples by High Performance Liquid Chromatography with Fluorescence Detection
    Shuiqiang Yu
    Jinmao You
    Xinxin Shi
    Xiaocong Zou
    Zhihao Lu
    Yu Wang
    Jiangkun Tan
    Zhiwei Sun
    Zan Li
    Zhongyin Ji
    Cuihua Song
    Journal of Fluorescence, 2024, 34 : 425 - 436
  • [2] Simple and rapid determination of estrogens and bisphenol A in water samples by high-performance liquid chromatography with electrochemical detection
    Ishiyama, T
    Shimadu, T
    Nudeshima, C
    Hoshi, J
    Sasaki, Y
    BUNSEKI KAGAKU, 2004, 53 (05) : 411 - 417
  • [3] Rapid Analysis of Loratadine in Human Serum by High-Performance Liquid Chromatography with Fluorescence Detection
    Plenis, A.
    Konieczna, L.
    Oledzka, I.
    Kowalski, P.
    ACTA CHROMATOGRAPHICA, 2010, 22 (01) : 69 - 79
  • [4] Rapid determination of loratadine in small volume plasma samples by high-performance liquid chromatography with fluorescence detection
    Amini, H
    Ahmadiani, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 227 - 230
  • [5] Determination of Peroxides in Environmental Samples by High Performance Liquid Chromatography with Fluorescence Detection
    Xu Jinrong
    Chen Zhongming
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (04) : 366 - 369
  • [6] Rapid determination of nosiheptide in meat and egg by liquid chromatography with fluorescence detection
    Horii, S
    Oku, N
    JOURNAL OF AOAC INTERNATIONAL, 2000, 83 (01) : 17 - 19
  • [7] DETERMINATION OF ESTROGENS IN PREGNANCY URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    ISHIDA, J
    KAI, M
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 431 (02): : 249 - 257
  • [8] Analysis of amines in water samples by high performance liquid chromatography-laser induced fluorescence detection
    Liu Fan
    Gao Fangyuan
    Tang Tao
    Sun Yuanshe
    Li Tong
    Zhang Weibing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (11) : 1112 - 1115
  • [9] Determination of ochratoxin A in Portuguese rice samples by high performance liquid chromatography with fluorescence detection
    Pena, A
    Cerejo, F
    Lino, C
    Silveira, I
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) : 1288 - 1293
  • [10] Determination of ochratoxin A in Portuguese rice samples by high performance liquid chromatography with fluorescence detection
    A. Pena
    F. Cerejo
    C. Lino
    I. Silveira
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1288 - 1293