Study of elevated- and ground pool fire flame horizontal lengths in cross airflows: Air entrainment change due to Coand a effect

被引:11
|
作者
Chen, Yuhang [1 ]
Fukumoto, Kazui [2 ]
Zhang, Xiaolei [1 ]
Lin, Yujie [1 ]
Tang, Fei [1 ]
Hu, Longhua [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Nagoya Univ, Inst Innovat Future Soc, Nagoya, Aichi 4648603, Japan
关键词
Elevated-and ground pool fire; Cross airflow; Flame horizontal lengths; Air entrainment; Coanda effect; LARGE-EDDY SIMULATION; WIND; ATTACHMENT; BEHAVIOR; GEOMETRY;
D O I
10.1016/j.proci.2022.09.038
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present study investigates experimentally the flame horizontal lengths of elevated pool fires and compares with those of ground pool fires in cross airflows. This, as a fundamental problem considering air entrainment and combustion structure change due to Coand a effect resulted from ground at leeward side, has not been quantified but is of practical significance. Experiments were performed employing both elevatedand ground square propane pool fires of various heat release rates in cross airflows from 0 & SIM;3.0 m/s with 224 test conditions in all. The overall flame horizontal length could be physically divided into two parts: part, L b ). Both the L m and the overall flame horizontal length showed to be significantly larger for a ground pool fire than those of an elevated one, due to the ground constraint effect on air entrainment at leeward side (Coand a effect). L b /( u 2 /g ) or L m /( u 2 /g ) of elevated fires is proportional to that of ground fires. Large eddy simulations for two representative fire scenarios were further conducted utilizing an in-house version of FireFOAM. The purpose of the simulations was to uncover the underlying physics of combustion and flow structures observed in the experiment. Finally, a model was proposed based on analysis of air entrainment, momentum- and buoyancy effects, which described well the overall flame horizontal lengths of both elevatedand ground pool fires generally as a function of non-dimensional heat release rate, normalized volumetric air entrainment and Froude numbers using L m and L b as length scales. This work provides new observation and basic quantification on elevated- and ground pool fire flame horizontal lengths considering air entrainment & COPY; 2022 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:4063 / 4073
页数:11
相关论文
共 4 条
  • [1] Experimental study of tunnel sidewall effect on flame characteristics and air entrainment factor of methanol pool fires
    Gao, Z. H.
    Liu, Z. X.
    Ji, J.
    Fan, C. G.
    Li, L. J.
    Sun, J. H.
    APPLIED THERMAL ENGINEERING, 2016, 102 : 1314 - 1319
  • [2] Experimental and numerical study on flame morphology, plume flow and air entrainment of pool fire under the influence of the built-in obstacle
    Wu, Jing
    Wang, Chen
    Xu, Jingbo
    Tong, Weixin
    Ji, Jie
    ENERGY, 2025, 320
  • [3] Effect of foam air mixing on flame intensification -- comparative experimental study of foam and water sprays extinguishing transformer oil pool fire
    Tu, Jinping
    Pau, Dennis
    Yang, Tianqi
    Nan, Shuai
    Zhang, Jiaqing
    Shang, Fengju
    Li, Kaiyuan
    FIRE SAFETY JOURNAL, 2022, 133
  • [4] Experimental study on the burning rate and flame dynamics of oil reservoir pool fire under cross-wind: Effect of lip height
    Deng, Lei
    Shi, Congling
    Mcamee, Margaret
    Tang, Fei
    ENERGY, 2024, 310