Comparison of the learning curve of intraoral scanning with two different intraoral scanners based on scanning time

被引:6
|
作者
Roth, Ivett [1 ]
Hermann, Peter [1 ]
Vitai, Viktoria [1 ]
Joos-Kovacs, Gellert Levente [1 ]
Geczi, Zoltan [1 ]
Borbely, Judit [1 ]
机构
[1] Semmelweis Univ, Dept Prosthodont, Szentkiraly St 47, H-1088 Budapest, Hungary
关键词
Intraoral scanner; Learning curve; Scanning time; DIGITAL IMPRESSION; CONVENTIONAL IMPRESSIONS; FIXED PROSTHODONTICS; OPERATOR EXPERIENCE; CLINICAL-EVALUATION; ARCH IMPRESSIONS; IMPLANT CROWNS; IN-VITRO; ACCURACY; PRECISION;
D O I
10.1186/s12903-023-02963-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe appearance of intraoral scanners (IOSs) in dental offices was an important milestones for the digital innovations in dentistry. Knowing the learning curve for intraoral scanning is crucial, because it can serve as a guideline for clinicians before buying a new IOS. The aim of the present in vivo study was to determine the learning curve required by dental students for intraoral scanning with the 3Shape Trios 4 IOS and the CEREC Primescan IOS, based on scanning time.MethodsA total of 20 dental students with no previous experience in intraoral scanning participated in the present study. 10 students scanned with Trios 4 (R) IOS (TRI) and 10 students took digital impressions with Primescan (R) IOS (CER). Every student created 15 digital impressions from patients. Prior to taking the impressions, theoretical and practical education was provided. The total scanning time included the upper and lower arches as well as bite registration, for which average values were calculated. Statistical analysis was performed using the Stata package with a mixed-effects generalized least squares regression models.ResultsThe average total scanning times were the following: TRI - 205 s for the 1st impression, 133.6 s for the 15th, CER - 289.8 s for the 1st impression, 147 s for the 15th. The model-based estimate of the difference between the two in case of TRI was 57.5 s, and in CER was 144.2 s which is a highly significant improvement in both cases (P < 0.0001). The slope of the scanning time vs. learning phase curve gradually approached flatness, and maintained a plateau: TRI - from the 11th measurement and CER - from the 14th measurement onward.ConclusionsGiven the limitations of the present study, we found difference between the learning curve of scanner types which are operate various principle of imaging. In case of the TRI fewer digital impressions (11 repeating) were sufficient to reach the average scanning time of an experienced user than using CER (14 repeating).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of the learning curve of intraoral scanning with two different intraoral scanners based on scanning time
    Ivett Róth
    Péter Hermann
    Viktória Vitai
    Gellért Levente Joós-Kovács
    Zoltán Géczi
    Judit Borbély
    BMC Oral Health, 23
  • [2] Learning curve of intraoral scanning by prosthodontic residents
    Al Hamad, Khaled Q.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02): : 277 - 283
  • [3] Scanning accuracy and scanning area discrepancies of intraoral digital scans acquired at varying scanning distances and angulations among 4 different intraoral scanners
    Button, Heather
    Kois, John C.
    Barmak, Abdul B.
    Zeitler, Jonathan M.
    Rutkunas, Vygandas
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 1044 - 1060
  • [4] Assessment of clinical reproducibility for intraoral scanning on different anatomical regions for the complete maxillary edentulous arch with two intraoral scanners
    Cameron, Andrew B.
    Abuzar, Menaka A.
    Tadakamadla, Santosh Kumar
    Evans, Jane L.
    JOURNAL OF DENTISTRY, 2025, 153
  • [5] Learning curve of digital intraoral scanning - an in vivo study
    Roth, Ivett
    Czigola, Alexandra
    Joos-Kovacs, Gellert Levente
    Dalos, Magdolna
    Hermann, Peter
    Borbely, Judit
    BMC ORAL HEALTH, 2020, 20 (01)
  • [6] Learning curve of digital intraoral scanning – an in vivo study
    Ivett Róth
    Alexandra Czigola
    Gellért Levente Joós-Kovács
    Magdolna Dalos
    Péter Hermann
    Judit Borbély
    BMC Oral Health, 20
  • [7] Influence of Operator Experience on Scanning Time and Accuracy with Two Different Intraoral Scanners-A Prospective Clinical Trial
    Thomas, Anjali Anna
    Jain, Ravindra Kumar
    TURKISH JOURNAL OF ORTHODONTICS, 2023, 36 (01) : 10 - 14
  • [8] Does the Learning Curve for Intraoral Scanning Vary Depending on the Device?
    Borges, Marianna S. N.
    Cardoso, Leandro
    Rea, Marcela T.
    Pedrazzi, Vinicius
    Tirapelli, Camila
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2025, 33 (01): : 33 - 41
  • [9] Intraoral digital scans: Part 2-influence of ambient scanning light conditions on the mesh quality of different intraoral scanners
    Revilla-Leon, Marta
    Jiang, Peng
    Sadeghpour, Mehrad
    Piedra-Cascon, Wenceslao
    Zandinejad, Amirali
    Oezcan, Mutlu
    Krishnamurthy, Vinayak R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 575 - 580
  • [10] SCANNING ACCURACY AND PRECISION IN 4 INTRAORAL SCANNERS: AN IN VITRO COMPARISON BASED ON 3-DIMENSIONAL ANALYSIS
    Nedelcu, Robert G.
    Persson, Anna S. K.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06): : 1461 - 1471