Quantitative flow cytometry leveraging droplet-based constriction microchannels with high reliability and high sensitivity

被引:4
|
作者
Yang, Guang [1 ,2 ]
Yang, Hongyu [1 ,3 ]
Zhang, Ting [1 ,3 ]
Gao, Chiyuan [1 ,3 ]
Chen, Deyong [1 ,2 ,3 ]
Wang, Junbo [1 ,2 ,3 ]
Chen, Jian [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, State Key Lab Transducer Technol, Aerosp Informat Res Inst, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing, Peoples R China
[3] Univ Chinese Acad Sci, Sch Future Technol, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
constriction microchannels; droplet microfluidics; high reliability; high sensitivity; quantitative flow cytometry; EXPRESSION; QUANTIFICATION; CELLS;
D O I
10.1002/cyto.a.24705
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presented a quantitative flow cytometry leveraging droplet-based constriction microchannels with high reliability and high sensitivity. Droplets encapsulating single cells and even distribution of fluorescein labeled antibodies removed from targeted cells deformed through the constriction microchannel where the excited fluorescent signals were sampled and interpreted into numbers of proteins based on volume equivalence in measurement of droplets and calibration of fluorescence. To improve the detection reliability, a comprehensive analysis and comparison of multiple stripping agents such as proteinase K, guanidine hydrochloride, and urea was conducted. To improve the detection sensitivity, light modulation was used to address electrical noises and quartz microchannels were fabricated to address optical noises. As a demonstration, based on this quantitative flow cytometry of droplet microfluidics, (1) mutant p53 expressions of single cells were quantified as 1.95 +/- 0.60x10(5) (n(cell) = 2918 of A431) and 1.30 +/- 0.70x10(5) (n(cell) = 3954 of T47D); (2) single-cell expressions of Ras, c-Myc, and beta -tubulin were quantified as 1.90 +/- 0.59x10(5), 4.39 +/- 1.44x10(5), and 2.97 +/- 0.81x10(5) (n(cell) = 3298 of CAL 27), 1.83 +/- 0.58x10(5), 2.08 +/- 0.13x10(6), and 1.96 +/- 0.74x10(5) (n(cell) = 5459 of WSU-HN6). As a microfluidic tool capable of quantitatively estimating single-cell protein expressions, this methodology may provide a new quantitative perspective for the field of flow cytometry.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [1] A droplet-based microfluidic flow cytometry enabling absolute quantification of single-cell proteins leveraging constriction channel
    Hongyu Yang
    Yuanchen Wei
    Beiyuan Fan
    Lixing Liu
    Ting Zhang
    Deyong Chen
    Junbo Wang
    Jian Chen
    Microfluidics and Nanofluidics, 2021, 25
  • [2] A droplet-based microfluidic flow cytometry enabling absolute quantification of single-cell proteins leveraging constriction channel
    Yang, Hongyu
    Wei, Yuanchen
    Fan, Beiyuan
    Liu, Lixing
    Zhang, Ting
    Chen, Deyong
    Wang, Junbo
    Chen, Jian
    MICROFLUIDICS AND NANOFLUIDICS, 2021, 25 (04)
  • [3] A Droplet-Based, Optofluidic Device for High-Throughput, Quantitative Bioanalysis
    Guo, Feng
    Lapsley, Michael Ian
    Nawaz, Ahmad Ahsan
    Zhao, Yanhui
    Lin, Sz-Chin Steven
    Chen, Yuchao
    Yang, Shikuan
    Zhao, Xing-Zhong
    Huang, Tony Jun
    ANALYTICAL CHEMISTRY, 2012, 84 (24) : 10745 - 10749
  • [4] A flow-free droplet-based device for high throughput polymorphic crystallization
    Yang, Shih-Mo
    Zhang, Dapeng
    Chen, Wang
    Chen, Shih-Chi
    LAB ON A CHIP, 2015, 15 (12) : 2680 - 2687
  • [5] High Sensitivity Flow Cytometry of Membrane Vesicles
    Stoner, Samuel A.
    Duggan, Erika
    Condello, Danilo
    Guerrero, Abraham
    Turk, James R.
    Narayanan, Padma K.
    Nolan, John P.
    CYTOMETRY PART A, 2016, 89A (02) : 196 - 206
  • [6] High throughput single cell counting in droplet-based microfluidics
    Lu, Heng
    Caen, Ouriel
    Vrignon, Jeremy
    Zonta, Eleonora
    El Harrak, Zakaria
    Nizard, Philippe
    Baret, Jean-Christophe
    Taly, Valerie
    SCIENTIFIC REPORTS, 2017, 7
  • [7] A droplet-based electricity generator with high instantaneous power density
    Xu, Wanghuai
    Zheng, Huanxi
    Liu, Yuan
    Zhou, Xiaofeng
    Zhang, Chao
    Song, Yuxin
    Deng, Xu
    Leung, Michael
    Yang, Zhengbao
    Xu, Ronald X.
    Wang, Zhong Lin
    Zeng, Xiao Cheng
    Wang, Zuankai
    NATURE, 2020, 578 (7795) : 392 - +
  • [8] High throughput single cell counting in droplet-based microfluidics
    Heng Lu
    Ouriel Caen
    Jeremy Vrignon
    Eleonora Zonta
    Zakaria El Harrak
    Philippe Nizard
    Jean-Christophe Baret
    Valérie Taly
    Scientific Reports, 7
  • [9] A droplet-based microfluidic immunosensor for high efficiency melamine analysis
    Choi, Jae-Won
    Min, Kyong-Mi
    Hengoju, Sundar
    Kim, Gil-Jung
    Chang, Soo-Ik
    deMello, Andrew J.
    Choo, Jaebum
    Kim, Hak Yong
    BIOSENSORS & BIOELECTRONICS, 2016, 80 : 182 - 186
  • [10] A droplet-based electricity generator with high instantaneous power density
    Wanghuai Xu
    Huanxi Zheng
    Yuan Liu
    Xiaofeng Zhou
    Chao Zhang
    Yuxin Song
    Xu Deng
    Michael Leung
    Zhengbao Yang
    Ronald X. Xu
    Zhong Lin Wang
    Xiao Cheng Zeng
    Zuankai Wang
    Nature, 2020, 578 : 392 - 396