A standardized method to measure the membranous urethral length (MUL) on MRI of the prostate with high inter- and intra-observer agreement

被引:9
|
作者
Veerman, Hans [1 ,2 ,3 ]
Hagens, Marinus J. J. [1 ,2 ,3 ]
Hoeks, Caroline M. M. [4 ]
van der Poel, Henk G. G. [1 ,2 ,3 ]
van Leeuwen, Pim J. J. [1 ,3 ]
Vis, Andre N. [2 ,3 ]
Heijmink, Stijn W. T. J. P. [5 ]
Schoots, Ivo G. G. [5 ,6 ]
de Haan, Margriet C. C. [5 ]
Boellaard, Thierry N. N. [5 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Urol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[2] Amsterdam Univ Med Ctr Locat Boelelaan, Dept Urol, Amsterdam, Netherlands
[3] Prostate Canc Network Netherlands, Amsterdam, Netherlands
[4] Diakonessenhuis Utrecht, Dept Radiol, Utrecht, Netherlands
[5] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiol, Amsterdam, Netherlands
[6] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
关键词
Prostatic neoplasms; Magnetic resonance imaging; Urethra; Observer variation; Urinary incontinence; URINARY CONTINENCE RECOVERY; RADICAL PROSTATECTOMY; INCONTINENCE; PREDICT; IMPACT;
D O I
10.1007/s00330-022-09320-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The membranous urethral length (MUL), defined as the length between the apex and penile base as measured on preoperative prostate magnetic resonance imaging (MRI), is an important predictor for urinary incontinence after radical prostatectomy. Literature on inter- and intra - observer agreement of MUL measurement is limited. We studied the inter- and intra-observer agreement between radiologists using a well-defined method to measure the MUL on the prostate MRI. Methods Prostate cancer patients underwent a preoperative MRI and robot-assisted radical prostatectomy (RARP) at one high-volume RARP center. MUL measurement was based on well-defined landmarks on sagittal T2-weighted (anatomical) images. Three radiologists independently performed MUL measurements retrospectively in 106 patients blinded to themselves, to each other, and to clinical outcomes. The inter- and intra-observer agreement of MUL measurement between the radiologists were calculated, expressed as intra-class correlation coefficient (ICC). Results The initial inter-observer agreement was ICC 0.63; 95% confidence interval (CI) 0.28-0.81. Radiologist 3 measured the MUL mean 3.9 mm (SD 3.3) longer than the other readers, interpreting the caudal point of the MUL (penile base) differently. After discussion on the correct anatomical definition, radiologist 3 re-assessed all scans, which resulted in a high inter-observer agreement (ICC 0.84; 95% CI 0.66-0.91). After a subsequent reading by radiologists 1 and 2, the intra-observer agreements were ICC 0.93; 95% CI 0.89-0.96, and ICC 0.98; 95% CI 0.97-0.98, respectively. Limitation is the monocenter design. Conclusions The MUL can be measured reliably with high agreement among radiologists.
引用
收藏
页码:3295 / 3302
页数:8
相关论文
共 50 条
  • [1] A standardized method to measure the membranous urethral length (MUL) on MRI of the prostate with high inter- and intra-observer agreement
    Hans Veerman
    Marinus J. Hagens
    Caroline M. Hoeks
    Henk G. van der Poel
    Pim J. van Leeuwen
    André N. Vis
    Stijn W. T. J. P. Heijmink
    Ivo G. Schoots
    Margriet C. de Haan
    Thierry N. Boellaard
    European Radiology, 2023, 33 : 3295 - 3302
  • [2] INTER- AND INTRA-OBSERVER AGREEMENT IN THE MILCH AND WEISS SYSTEMS
    Charles Lozoya, Sergio
    Trevino Baez, Joaquin Dario
    Rangel Flores, Jesus Maria
    Brizuela Ventura, Jesus Miguel
    Araiza Topete, Omar
    Alcazar Juarez, Andrea
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 218 - 221
  • [3] Intrapartum ultrasound for cervical dilatation: Inter- and intra-observer agreement
    Hanidu, Arwa
    Kovalenko, Mariya
    Usman, Sana
    Monasta, Lorenzo
    Zamagni, Giulia
    Stampalija, Tamara
    Lees, Christoph
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2024, 103 (12) : 2455 - 2464
  • [4] Intrapartum ultrasound for cervical dilatation: Inter- and intra-observer agreement
    Hanidu, Arwa
    Kovalenko, Mariya
    Usman, Sana
    Monasta, Lorenzo
    Zamagni, Giulia
    Stampalija, Tamara
    Lees, Christoph
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2024, 132 : 39 - 39
  • [5] Inter- and intra-observer agreement in arthroscopic assessment of the long head of the biceps
    Saad, Maxime
    Charousset, Christophe
    Berhouet, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (02)
  • [6] Spondyloarthritis-related and degenerative MRI changes in the axial skeleton - an inter- and intra-observer agreement study
    Arnbak, Bodil
    Jensen, Tue Secher
    Manniche, Claus
    Zejden, Anna
    Egund, Niels
    Jurik, Anne Grethe
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [7] Spondyloarthritis-related and degenerative MRI changes in the axial skeleton - an inter- and intra-observer agreement study
    Bodil Arnbak
    Tue Secher Jensen
    Claus Manniche
    Anna Zejden
    Niels Egund
    Anne Grethe Jurik
    BMC Musculoskeletal Disorders, 14
  • [8] Perineal ultrasound for the measurement of urethral mobility: a study of inter- and intra-observer reliability
    Pizzoferrato, Anne-Cecile
    Timoh, Krystel Nyangoh
    Bader, Georges
    Fort, Julie
    Fritel, Xavier
    Fauconnier, Arnaud
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2019, 30 (09) : 1551 - 1557
  • [9] Perineal ultrasound for the measurement of urethral mobility: a study of inter- and intra-observer reliability
    Anne-Cécile Pizzoferrato
    Krystel Nyangoh Timoh
    Georges Bader
    Julie Fort
    Xavier Fritel
    Arnaud Fauconnier
    International Urogynecology Journal, 2019, 30 : 1551 - 1557
  • [10] Inter- and Intra-observer Reliability of MRI for Lumbar Lateral Disc Herniation
    Kim, Seong Wan
    Yeom, Jin S.
    Park, Seong Kyu
    Chang, Bong Soon
    Lee, Dong-Ho
    Lee, Jae Hyup
    Park, Kun-Woo
    Seo, Eun Seok
    Lee, Choon-Ki
    CLINICS IN ORTHOPEDIC SURGERY, 2009, 1 (01) : 34 - 39